Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação GE Monogram, Modelo MONOGRAM ZBD6800

Fabricante : GE Monogram
Arquivo Tamanho: 678.39 kb
Arquivo Nome :
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


• All models have a full length door without the traditional access panel. • These dishwashers may be installed beneath countertops of stone or other materials that will not accept screws. No trim kit required. *Dishwasher models ZBD6890 and ZBD0700 require a 3/4” thick custom panel and will be 24-3/4” deep. Figure A 4 Installation Preparation DRAIN REQUIREMENTS • Follow local codes and ordinances. • Do not exceed 10 feet distance to drain. • Do not connect drain lines from other devices to the dishwasher drain hose. NOTE: An air gap must be used, if waste tee or disposer connection is less than 18" above floor to prevent siphoning. DETERMINE DRAIN METHOD The type of drain installation depends on the following question. ..Do local codes or ordinances require an air gap? ..Is waste tee less than 18" above floor? If the answer to either question is YES, Method 1 MUST be used. • If the answers are NO, either method may be used. CABINET PREPARATION • Drill a 1-1/2" dia. hole in the cabinet wall within the shaded areas shown in Figure A for the drain hose connection. The hole should be smooth with no sharp edges. Method 1—Air Gap with Waste Tee or Disposer An air gap must be used when required by local codes and ordinances. The air gap must be installed according to manufacturers instructions. Method 2—“High Drain Loop” with Waste Tee or Disposer Figure C Figure D 32" Min.18" Min. 32" Min. 18" Min. IMPORTANT — When connecting drain line to disposer, check to be sure that drain plug has been removed. DISHWASHER WILL NOT DRAIN IF PLUG IS LEFT IN PLACE. Remove Hopper Plug 5 Installation Preparation PREPARE ELECTRICAL WIRING WARNING FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Electrical Requirements • This appliance must be supplied with 120V, 60 Hz., and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker Receptacle or time delay fuse. Location • Wiring must be 2-wire with ground and rated for Area Ground Figure E 75°C (176°F). Black White 18" 6" 24" from Wall 3" from Cabinet Alternate Receptacle Location 1-1/2" Dia. Hole (Max.)18" 6" • If the electrical supply does not meet the above requirements, call a licensed electrician before For models equipped with power cord: Do not modify proceeding. the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified Grounding Instructions—Cable Direct technician. This appliance must be connected to a grounded metal, permanent wiring system, or an equipment grounding Cabinet Preparation and Wire Routing conductor must be run with the circuit conductors and • The wiring may enter the opening from either side, be connected to the equipment grounding terminal or rear or the floor within the shaded area. lead on the appliance. • Cut a 1-1/2" max. dia. hole to admit the electrical cable. Cable direct connections may pass through Grounding Instructions—Power Cord Models the same hole as the drain hose and hot water line, This appliance must be grounded. In the event of a if convenient. If cabinet wall is metal, the hole edge malfunction or breakdown, grounding will reduce the must be covered with a bushing. risk of electric shock by providing a path of least NOTE: Power cords with plug must pass through a resistance for electric current. This appliance is separate hole. equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be Electrical Connection to Dishwasher plugged into an appropriate outlet that is installed and Electrical connection is on the right front of grounded in accordance with all local codes and dishwasher. ordinances. • For cable direct connections the cable must be routed as shown in Figure E. Cable must extend WARNING a minimum of 24" from the rear wall. The improper connection of the equipment • For power cord connections, install a 3-prong grounding conductor can result in a risk grounding type receptacle in the sink cabinet rear of electric shock. Check with a qualified wall, 6" min. or 18" max. from the opening, 6" to 18" electrician or service representative if you above the floor. are in doubt that the appliance is properly grounded. 6 Installation Instructions PREPARE HOT WATER LINE • The line may enter from either side, rear or floor within the shaded area shown in Figure F. • The line may pass through the same hole as the electrical cable and drain hose. Or, cut an additional 1-1/2" dia. hole to accommodate the water line. If power cord with plug is used, water line must not pass through power cord hole. BEFORE YOU BEGIN Locate and set aside (for use in Step 12) the 2 Phillips special head screws wrapped with yellow tape and stuck to the top or side of the dishwasher. Remove drain hose from upper rack, if it has not been pre-installed, and set aside for use in Step 7. 1-1/2" Dia. Shut-off Hole...

Este manual também é adequado para os modelos :
Máquinas de lavar louça - MONOGRAM ZBD0710 (678.39 kb)
Máquinas de lavar louça - MONOGRAM ZBD6890 (678.39 kb)
Máquinas de lavar louça - MONOGRAM ZBD6880 (678.39 kb)
Máquinas de lavar louça - MONOGRAM ZBD0700 (678.39 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias