Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Jackson, Modelo AJ-100CGP

Fabricante : Jackson
Arquivo Tamanho: 9.55 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: N/A 2 SECTION 1: SPECIFICATION INFORMATION ELECTRICAL REQUIREMENTS AJ-64CE MODELS TOTAL VOLTS PH HZ AMPS 208 1 60 139 A 230 1 60 128 A TYPICAL ELECTRICAL CIRCUIT 175 AMP 175 AMP AJ-86CE MODELS TOTAL VOLTS PH HZ AMPS 208 1 60 145 A 230 1 60 134 A TYPICAL ELECTRICAL CIRCUIT 200 AMP 175 AMP 208 230 460 3 3 3 60 60 60 82 A 76 A 38 A 110 AMP 100 AMP 50 AMP 208 230 460 3 3 3 60 60 60 86 A 79 A 39 A 110 AMP 100 AMP 50 AMP AJ-64CS MODELS TOTAL VOLTS PH HZ AMPS 208 1 60 19 A 230 1 60 19 A TYPICAL ELECTRICAL CIRCUIT 25 AMP 25 AMP AJ-86CGP MODELS TOTAL VOLTS PH HZ AMPS 208 1 60 26 A 230 1 60 26 A TYPICAL ELECTRICAL CIRCUIT 35 AMP 35 AMP 208 230 460 3 3 3 60 60 60 13 A 13 A 7 A 20 AMP 20 AMP 15 AMP 208 230 460 3 3 3 60 60 60 17 A 17 A 9 A 25 AMP 25 AMP 15 AMP AJ-86CS MODELS TOTAL VOLTS PH HZ AMPS 208 1 60 25 A 230 1 60 25 A TYPICAL ELECTRICAL CIRCUIT 35 AMP 35 AMP 208 230 460 3 3 3 60 60 60 16 A 16 A 8 A 20 AMP 20 AMP 15 AMP AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: N/A 3 SECTION 1: SPECIFICATION INFORMATION ELECTRICAL REQUIREMENTS (CONTINUED)/D226 STEAM BOOSTER PARAMETERS AJ-100CE MODELS D226 STEAM BOOSTER TYPICAL TOTAL ELECTRICAL ELECTRICAL REQUIREMENTS: VOLTS PH HZ AMPS CIRCUIT VOLTAGE (V) 208-230 208 1 60 148 A 200 AMP FREQUENCY (HZ) 60 230 1 60 136 A 175 AMP PHASE SINGLE 208 3 60 88 A 110 AMP 230 3 60 81 A 110 AMP WATER REQUIREMENTS: 460 3 60 41 A 60 AMP INCOMING WATER TEMPERATURE (MINIMUM) 110°F FLOW PRESSURE (PSI) 20±5 AJ-100CGP MODELS STEAM REQUIREMENTS: TYPICAL INCOMING STEAM PRESSURE (PSIG) 15-25 TOTAL ELECTRICAL VOLTS PH HZ AMPS CIRCUIT HEAT EXCHANGER SPECIFICATIONS:* 208 1 60 28 A 35 AMP TUBESIDE WORKING PRESSURE (PSI) 125 230 1 60 28 A 35 AMP SHELLSIDE WORKING PRESSURE (PSI) 125 TUBESIDE HYDROSTATIC TEST PRESSURE (PSI) 250 208 3 60 19 A 25 AMP SHELLSIDE HYDROSTATIC TEST PRESSURE (PSI) 230 3 60 19 A 25 AMP 188 460 3 60 10 A 15 AMP MAXIMUM OPERATING TEMPERATURE 295°F MAXIMUM SHELLSIDE STEAM PRESSURE (PSI) 125 AJ-100CS MODELS TYPICAL * - Indicates typical design criteria but is subject to changeTOTAL ELECTRICAL without notice. For more information, contact you authorized VOLTS PH HZ AMPS CIRCUIT Jackson service representative. 208 1 60 28 A 35 AMP 230 1 60 28 A 35 AMP WATER OUTLET SAFETY VALVE 208 3 60 18 A 25 AMP SET PRESSURE (PSI): 125 230 3 60 18 A 25 AMP STEAM RELIEF VALVE SET PRESSURE (PSI): 50 460 3 60 9 A 15 AMP NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice. AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: N/A 4 Right Side 34 [864mm] 21 [533mm] 25 [635mm] 12 [307mm] 25 [635mm] Table to Table Overall Dish Clearance B Left to Right Drive Unit Left Side 661 2 [1692mm] 1 2 [15mm] 84 [2134mm] With Doors Open Rear of Machine Legend to Drawing A - Machine water inlet 3/4" NPT, 180°F Hi-temp, 140°F Low-temp minimum B - Electrical connection C - Drain connection 1-1/2" NPT D - Vent collar - Optional E - Vent cowl standard Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 1 [25mm] 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with Cover Plate. Floor Sink Or Drain With 3" [76 mm] Minimum Drain Line 25 [637mm] 64 [1626mm] 72 [1829mm] 80 [2032mm] 8 [204mm] 14 [355mm] Scrap Trough Minimum 21 [535mm] 651 2 [1665mm] A Drive Unit Front View 751 2 [1915mm] 621 2 [1588mm] 29 [737mm] 61 2 [165mm] 10 [254mm] 7 [178mm] D E C 4 [102mm] 8 [203mm] 14 [354mm] Minimum 10" High Table Backsplash Scrap Trough 323 4 [833mm] 35 [891mm] 5 [127mm] 81 2 [218mm] C B 241 2 [622mm] 3/4" [19 mm] Table Turndown Flange 3/4" Max 21" [533 mm] Rack Rail Height Above Dishtable 1/4" [6mm] - 5/16" [8mm] Rack Rail Tub Table Use Silicone Sealer Between Table and Lip of Machine to Prevent Leakage Recommended Table Fabrication Note: Tub Will Accept a Table Flange Up to 24 7/8" [632 mm] 601 4 [1530mm] SECTION 1: SPECIFICATION INFORMATION AJ-64 ELECTRIC - LEFT TO RIGHT 5 AJ-64 Conveyor Series Technical Manual 7610-003-30-93 Issued: 05-02-2006 Revised: 09-29-2007 Right Side 34 [864mm] 21 [533mm] 25 [635mm] 12 [307mm] 25 [635mm] Table to Table Overall Dish Clearance B Right to Left Drive Unit Left Side 661 2 [1692mm] 1 2 [15mm] 84 [2134mm] With Doors Open Rear of Machine Legend to Drawing A - Machine water inlet 3/4" NPT, 180°F Hi-temp, 140°F Low-temp minimum B - Electrical connection C - Drain connection 1-1/2" NPT D - Vent collar - Optional E - Vent cowl standard Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 1 [25mm] 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with Cover Plate. Floor Sink Or Drain With 3" (76 mm) Minimum Drain Line 25 [637mm] 64 [1626mm] 72 [1829mm] 80 [2032mm] 8 [204mm] 21 [535mm] 651 2 [1665mm] A ...

Este manual também é adequado para os modelos :
Máquinas de lavar louça - AJ-100CE (9.55 mb)
Máquinas de lavar louça - AJ-100CS (9.55 mb)
Máquinas de lavar louça - AJ-64CE (9.55 mb)
Máquinas de lavar louça - AJ-64CS (9.55 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias