|
Facilidade de uso
44 [1118mm] 52 [1321mm] 60 [1524mm] 601 4 [1530mm] 8 [203mm] 8 [203mm] 14 [355mm] Scrap Trough Minimum 21 [533mm] B 12 [307mm] 651 2 [1667mm] 1 [25mm] 661 2 [1692mm] 133 4 [346mm] 7 [178mm] SECTION 1: SPECIFICATION INFORMATION AJ-44T ELECTRIC - LEFT TO RIGHT 4 AJ-44T Series Technical Manual 7610-003-07-21 Issued: 03-21-2006 Revised: 09-29-2007 Right to Left Drive Unit Left Side Drive Unit Front View Right Side 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with Cover Plate. Floor Sink Or Drain With 3" (76 mm) Minimum Drain Line 3/4" (19 mm) Table Turndown Flange 3/4" Max 21" (533 mm) Rack Rail Height Above Dishtable 1/4" (6mm) - 5/16" (8mm) Rack Rail Tub Table Use Silicone Sealer Between Table and Lip of Machine to Prevent Leakage Recommended Table Fabrication Note: Tub Will Accept a Table Flange Up to 24 7/8" (632 mm) 1 2 [15mm] 84 [2134mm] 751 2 [1919mm] 621 2 [1590mm] 34 [864mm] 29 [737mm] 6 [152mm] 71 2 [193mm] 21 [533mm] 25 [635mm] 25 [635mm] 10 [254mm] 7 [178mm] D E A C B A 181 2 [467mm] 25 [635mm] 4 1/2 [114mm] 4 [102mm] Table to Table Overall With Doors Open Rear of Machine Dish Clearance 71 2 [190mm] C B Legend A - Machine water inlet 3/4" NPT, 180°F Hi-temp,140°F Low-temp minimum B - Electrical connection C - Drain connection 1-1/2" NPT D - Vent collar - Optional E - Vent cowl standard Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 44 [1118mm] 52 [1321mm] 60 [1524mm] 601 4 [1530mm] 8 [203mm] 8 [203mm] B 21 [533mm] 12 [307mm] 651 2 [1667mm] 1 [25mm] 661 2 [1692mm] 133 4 [349mm] 7 [178mm] A SECTION 1: SPECIFICATION INFORMATION AJ-44T ELECTRIC - RIGHT TO LEFT 5 AJ-44T Series Technical Manual 7610-003-07-21 Issued: 03-21-2006 Revised: 09-29-2007 Drive Unit Front View Right Side 751 2 [1919mm] 621 2 [1590mm] 34 [864mm] 29 [737mm] 6 [152mm] 81 2 [218mm] 21 [533mm] 25 [635mm] 12 [307mm] 25 [635mm] 10 [254mm] 7 [178mm] D E B 181 2 [467mm] 4 [102mm] 8 [206mm] Table to Table Overall Dish Clearance 14 [356mm] Minimum 10" High Table Backsplash Scrap Trough 203 4 [527mm] 83 4 [222mm] 113 4 [298mm] 143 4 [375mm] 6 [154mm] 30 [763mm] 14 [357mm] 71 4 [185mm] 11 4 [35mm] 6 [152mm] 36 [914mm] 311 4 [795mm] 61 2 [165mm] 261 2 [673mm] B Left to Right Drive Unit Left Side 661 2 [1692mm] 1 2 [15mm] 84 [2134mm] With Doors Open Rear of Machine Legend to Drawing A - Machine water inlet 3/4" NPT, 180°F Hi-temp,140°F Low-temp minimum B - Electrical connection C - Drain connection 1-1/2" NPT D - Vent collar - Optional E - Vent cowl standard F - 3/4" NPT 180°F Water Inlet for wash tank fill, final rinse, & tank heating. From gas booster heater. Interconnecting hose provided by manufacturer. G - 3/4" NPT 140°F Water inlet for gas booster heater. H - 3/4" NPT 180°F Water Outlet connection to line on dishmachine. Connection hose provided by manufacturer. J - 3/4" NPT Gas Connection K - 4" OD Vent pipe connection. Flue to be installed to meet local codes by installing contractor. Note: All vertical dimensions are +/- 1/2" from floor due to adjustable bullet feet. 1 [25mm] H G J K 3/4" (19 mm) Table Turndown Flange 3/4" Max Rack Rail Height 21" (533 mm) Above Dishtable 1/4" (6mm) - 5/16" (8mm) Rack Rail Tub Table Use Silicone Sealer Between Table and Lip of Machine to Prevent Leakage Recommended Table Fabrication Note: Tub Will Accept a Table Flange Up to 24 7/8" (632 mm) F 601 4 [1530mm] 4" (102 mm) wide x 16" (406 mm) long cutout in Vent Cowl/Splash Shield. Shipped with Cover Plate. Floor Sink Or Drain With 3" (76 mm) Minimum Drain Line 25 [637mm] 44 [1118mm] 52 [1321mm] 60 [1524mm] 8 [204mm] 14 [355mm] Scrap Trough Minimum 21 [535mm] 36 [914mm] H G J K C 71 2 [190mm] C 133 4 [346mm] A 661 4 [1684mm] A SECTION 1: SPECIFICATION INFORMATION AJ-44T GAS - LEFT TO RIGHT 6 AJ-44T Series Technical Manual 7610-003-07-21 Issued: 03-21-2006 Revised: 09-29-2007 Right to Left Drive Unit Left Side Drive Unit Front View Right Side 661 2 [1692mm] 1 2 [15mm] 84 [2134mm] 751 2 [1919mm] 621 2 [1590mm] 34 [864mm] 29 [737mm] 7 [178mm] 6 [152mm] 71 2 [191mm] 81 2 [218mm] 21 [533mm] 25 [635mm] 12 [307mm] 25 [635mm] 10 [254mm] 7 [178mm] D E A C A B 181 2 [467mm] 4 [102mm] 8 [206mm] 41 [1042mm] Table to Table With Doors Open Overall Rear of Machine Dish Clearance 203 4 [527mm] 83 4 [222mm] 113 4 [298mm] 143 4 [375mm] 6 [152mm] 30 [763mm] 14 [357mm] 71 4 [185mm] 11 4 [35mm] C B Legend to Drawing A - Machine water inlet 3/4" NPT, 180°F Hi-temp,140°F Low-temp minimum B - Electrical connection C - Drain connection 1-1/2" NPT D - Vent collar - Optional E - Vent cowl standard F - 3/4" NPT 180°F Water Inlet for wash tank fill, final rinse, & tank heating. From gas booster heater. Interconnecting hose provided by manufacturer. G - 3/4" NPT 140°F Water inlet for gas booster heater. H - 3/4" NPT 180°F Water Outlet connection to line on dishmachine. Connection hose provided by manufacturer. J - 3/4" NPT Gas Connection K - 4" OD Vent pipe connection. Flue to be installed to meet local codes by ...
Este manual também é adequado para os modelos :Máquinas de lavar louça - AJ-44TG (6.45 mb)
Máquinas de lavar louça - AJ-44TS (6.45 mb)
Máquinas de lavar louça - AJ-66TE (6.45 mb)
Máquinas de lavar louça - AJ-66TG (6.45 mb)