Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Ei Electronics, Modelo Ei151TLR

Fabricante : Ei Electronics
Arquivo Tamanho: 93.82 kb
Arquivo Nome : fa0897ee-bd08-414d-9e6c-460b5c860a92.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


These rechargeable lithium cells are designed to have a ten year life and outlast the life of the smoke alarm itself, whilst providing up to six months of smoke alarm operation without mains power. The Ei151TLR allows the detector to be controlled remotely by either a “Test/Hush” Switch (Ei152), a “Locate” Switch (Ei159) or a Manual Call Point (MCP400). If the Ei151TLR is also interconnected to other Ei mains powered alarms then the whole system will be controllable remotely. The Ei151TLR has the ability to interconnect up to twelve alarms to allow all alarms to sound if just one of the interconnected alarms should be triggered. The Ei151TLR has built in circuitry to aid suppression of voltage transients and RF interference to further reduce the chances of false alarms under such conditions. Operation The green indicator will illuminate to show mains power is present The red indicator will flash rapidly to show an alarm condition for the smoke detector The “Test/Hush” button will either silence false alarms or perform a unit self test. In “Test” mode the alarm will perform a self test and sound the horn In “Hush” mode the alarm enters a ten minute period of reduced sensitivity to overcome false alarm conditions, and will then automatically reset itself When interconnected to other Ei mains powered alarms, an alarm on one detector will trigger all other interconnected alarms within one second (only the triggered alarm will flash a red indicator) The smoke detector will emit a beep and flash the red light every 40 seconds to indicate that the battery back up is depleted and needs recharging The detector can be controlled remotely by either a “Test/Hush” Switch (Ei152), a “Locate” Switch (Ei159) or a Manual Call Point (MCP400). Shannon Free Zone, Shannon, Co. Clare, Ireland. Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior not ice. Ei151TLR DataSht RevB Model Ei151TLR Ionisation Model Ei151TLR Ionisation Technical Specification Sensor Ionisation Sensitivity: Complies with BS 5446 Part 1: 2000 Source: Americium 241 Button Test: Simulates the effect of smoke and checks electronics and horn. Supply Voltage: 230V AC Battery back-up: Rechargeable lithium cells Power-On Indicator: Continuous green LED Alarm: Electronic Piezoelectric horn in unit Alarm Sound Output: 85dB (minimum) at 3m Alarm Status: Red LED flashes every second on unit sensing fire Temperature Range: 0° to 40°C Humidity Range: 15% to 95% Relative Humidity Remote control: Ei152, Ei159 or MCP400 Interconnect: Up to 12 interconnected Ei150/151TL/151TLR/154TL/155/1 56TLH/156TLR smoke or heat alarms, along with an EI158 relay base Fixing: Screw fixings supplied Plastic material: UL94VO flame retardant Dimensions: 140mm x 120mm x 46mm Weight: 227g Warranty: 5 year (limited) warranty Approvals: Kitemarked to BS EN 14604:2005, CE Approved Specifications are subject to change Installation & Placement Wiring for Interconnected Alarms Be very careful about correctly wiring the alarms as mixing Live and Neutral will blow/damage interconnected alarms. Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of areas of “dead air” close to corners of rooms and apexes of ceilings, which could result in the prevention of smoke reaching the smoke detector Please consult instruction booklet for specific installation details Important Precaution: Do not install the actual smoke/heat alarm itself in new or renovated buildings until all work is completed (including floor coverings) and the building has been fully cleaned. The wiring can be installed when appropriate. (Excessive dust and debris from building work can contaminate the smoke chamber and cause problems, and it will also invalidate the guarantee). If it must be installed, cover it completely, particularly around the edges, with a dust cover (eg. a plastic bag), until all cleaning is finished.. Connect wires to the unit as in wiring diagram. All wiring must comply with local codes. Shannon Free Zone, Shannon, Co. Clare, Ireland. Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: E & OE As our policy is one of continuous product development, we reserve the right ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias