Facilidade de uso


The detector is inserted into the IS Detector Base ASEX45681- 215 (not illustrated) and it can be protected against theft. intrinsically safe Ex classification EEx ia IIC T5 Operating voltage Supply through loop voltage Current consumption typ. 340.A (quiescent) Ambient temperature -20°C to +40°C (no condensation or icing) Relative humidity 0 – 95% (no condensation) Dimensions o . H 100 . 42 (mm) Colour white Weight 100g Building Safety. Building Security. A © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 Ex-ApoDisc_DBL_LST_EN_0804.PDF • PAGE 1 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED Approval EECS ATEX 0073 LPCB 010q Order number 241024 Order name IS Optical Smoke Detector/Anal./XP95/Apo AOEX-55000-640 IS Thermal Detector AWEX-55000-440 The addressable Intrinsically Safe Thermal Detector AWEX-55000-440 (fig. B) uses the heat principle and was developed for the fire detection in hazardous areas. The heat detector must always be connected via a safety barrier, which has been approved for this detector, and a protocol interface. Furthermore, the relevant country specific regulations always have to be observed. The detector is assigned to Class A2S and can be used up to a room height of 6m. Depending on the parameter setup in the fire detection control panel, the detector can operate either as maximum heat detector with an alarm temperature of 55°C, or as rate-of-rise heat detector with a maximum temperature of 55°C. Specifications Ignition protection The proven ADM loop technology with Apollo/Discovery protocol establishes a permanent communication between the fire detection control panel and the detector. That ensures a periodical function testing of the detector. Fires are safely detected in the control panel by continuously analysing the measured values. The two LEDs with 360° visibility indicate the activated condition of the detector. The detector address is selected by means of a code card in the detector base. Therefore the detector can be changed without additional tools. The detector is inserted into the IS Detector Base ASEX45681- 215 (not illustrated) and it can be protected against theft. intrinsically safe Ex classification EEx ia IIC T5 Operating voltage Supply through loop voltage Current consumption typ. 300.A (quiescent) Ambient temperature -20°C to +40°C (Class T5, no condensation or icing) -20°C to +60°C (Class T4, no condensation or icing) Relative humidity 0 – 95% (no condensation) Dimensions o . H 100 . 42 (mm) Colour white Weight 100g Approval EECS ATEX 0073 LPCB 010p Order number 242036 Order name IS Thermal Detector/Anal./XP95/Apo AWEX-55000-440 IS Detector Base ASEX-45681-215 The IS Detector Base ASEX-45681-215 is designed to The detector address is selected by means of a code accommodate intrinsically safe intelligent fire detectors card in the detector base. Therefore the detector can Series XP95 for use in ADM loops with Apollo/Discovery be changed without additional tools. protocol. The base is designed for surface mounting in hazardous Due to its robust multi-wire screw terminals, the detec-areas. A mechanical theft protection of the detector can tors can be wired with ease, thus achieving a secure optionally be activated at the detector base. and durable connection. Building Safety. Building Security. A © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 Ex-ApoDisc_DBL_LST_EN_0804.PDF • PAGE 2 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED The Protocol Interface API-55000-855 (fig. D) serves for the design of an intrinsically safe electric circuit in ADM loop technology. It allows the bidirectional data traffic between fire detection control panel and detectors in hazardous areas, via an ADM loop with Apollo/Discovery protocol. The interface is always used together with the Safety Barrier AES-29600-098. Specifications Ignition protection Ex classification intrinsically safe EEx ia IIC T5 Operating voltage Current consumption at 24V Ambient temperature Relative humidity Dimensions W . H . D Weight Order number Supply through loop voltage 1mA -10°C to +60°C 10 – 95% (no condensation) 93 . 110 . 20 (mm) 100g 228005 Order name Protocol Interface/Anal./XP95/Apo API-55000-855 Specifications Ambient temperature -20°C to +60°C (no condensation or icing) Relative humidity 10 – 95% (no condensation) Dimensions o . H 100 . 15 (mm) Colour white Weight 50g Order number 246027 Order name IS Detector Base/Anal./Apo ASEX-45681-215 Safety Barrier AES-29600-098 The Safety Barrier AES-29600-098 (fig. C) is used for of fire detectors in hazardous areas. Due to the galvanic intrinsically safe electric circuits. The built-in zener bar-isolation, the earth leakage monitoring can remain actirier and the safe galvanic isolation allow the connection vated in the fire detection control panel. Specifications Ignition protection intrinsically safe Ex classification...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias