Facilidade de uso


The front load battery door allows users to change batteries without having to remove the smoke alarm from the mounting bracket. It’s unique battery compartment design will not close if the battery is installed incorrectly, leaving you assured the batteries are properly installed. A locking feature, located on the back of the alarm allows the battery door to lock if there is a concern of theft or tampering. Along with its other premium features such as Hush®, that silences nuisance alarms, this product was designed to help warn families from the dangers of smoke and fire hazards while providing its users with easy to use features to keep a maintained smoke alarm with working battery. This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home. Features and Benefits • Battery Operated (9V Battery Included) – Protects even during power outages. • Front Load Battery Door – Provides easy access, which reduces the installation and battery replacement time. • Hush® Feature – Temporarily silences nuisance alarms. • Tamper Resist Feature – Battery door can be locked to prevent battery removal • Adjustable Mounting Bracket – Allows for fast installation and perfect alignment. • Test/Reset Button – Large and easy to use; tests all electronic circuitry, horn and battery function. • Attractive Design – Modern design appeals to homeowners. Battery Operated Smoke Alarm Model 0976 w/ Front Load Battery Door Architectural and Engineering Specifications The smoke alarm shall be Kidde Model 0976 or approved equal. It shall be powered by a 9V battery source. The unit shall incorporate an ionization sensor with nominal sensitivity of 0.92%/ft. The temperature operating range shall be between 40°F and100°F (4°C and 38°C) and the humidity operating range shall be 5% - 95% relative humidity. The alarm shall provide optional tamper resistance that locks the battery door closed. No additional pieces shall be required to activate this feature. The alarm shall include an easy access battery compartment that is opened and closed by pressing on the battery door. The 9V battery carrier will ensure proper battery power protection by not allowing the battery door to close if the battery is placed in the unit incorrectly or if a battery is not present. The unit shall also provide an optional tamper resistant switch that will help prevent the battery door from being opened. The unit shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. The unit shall include the Hush® feature that silences the unit for approximately 7 minutes if a nuisance condition occurs. The alarm will chirp every 30 -40 seconds while in hush mode and will automatically reset. The unit shall incorporate a red LED, which will flash once every 30-40 seconds to indicate the alarm is operating properly and will flash once per every 1.5 seconds when the unit is alarming and will remain so until the air is cleared. The unit shall at a minimum meet the requirements of UL217, NFPA72, and The California State Fire Marshall, NFPA101 (0ne and two family dwellings), Federal Housing Authority (FHA), Housing and Urban Development (HUD). Technical Specifications Model Number: 0976 Power Source: 9V Battery Audio Alarm: 85dB at 10ft Temperature Range: 40.F to 100.F (4.C to38.C) Humidity Range: 5%-95% relative humidity (RH) Sensor: Ionization Size: 5” in diameter x 1.79” depth Weight: .5lbs LED: Red, alarm condition Warranty: 10 year limited warranty 5" alarm5.6" w/trim 1.79" Ordering Information Single Clam UPC: 0-47871-05672-9 Part Number I 2 of 5 Pack Quantity Dimensions (w x d x h inches) Weight Case/ Skid Layers/ Skid Skid Weight N/A** N/A Individual 7 x 3 x 11 .5lbs N/A N/A N/A 0976-9997 100 47871 05672 6 PDQ (2 units) 7.75 x 6 x 11.75 1lb 105 7 105lbs 0976-9996 200 47871 05672 3 Cut Case (12 units) 16 x 20.75 x 11.75 6lbs 18 3 108lbs 21006133 300 47871 05672 0 Power Tower (36 units) 20 x 24 x 35.5 (incl. pallet) 18lbs 3 3 18lbs **Not for sale by individual unit Twin Clam UPC: 0-47871-05678-1 UNIT PDQ CUT CASE Part Dimensions Case/ Layers/ Skid Number I 2 of 5 Pack Quantity (w x d x h inches) Weight Skid Skid Weight 1 212 N/A** N/A Individual 14.5 x 2 x 11.25 1lbs N/A N/A N/A 0976-9995 100 47871 05678 8 Cut Case (10 units) 16 x 20.75 11.75 10lbs 16 4 160lbs 21005691 200 47871 05678 5 Power Tower (30 units) 20 x 24x 41 (incl. Pallet) 30lbs 3 3 30lbs **Not for sale by individual unit 1 10 30 1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 POWER TOWER UNIT CUT CASE Distributed by: P/N: KL-0918 sheet rev. 01-2009 ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias