Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Sierra Monitor Corporation, Modelo Gas Sensor Modules 4101

Fabricante : Sierra Monitor Corporation
Arquivo Tamanho: 125.64 kb
Arquivo Nome : 4101_series.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Utilizing electrochemical sensor technology the Model 4101 provides accurate monitoring of hazardous gas conditions. Proven sensor design matched with reliable state-of-the-art electronics results in the ideal complete single channel package to protect your plant and personnel. Automatic Low Sensitivity Check Monitoring integrity is ensured with the automatic low sensitivity check. After calibration, a sensor sensivity check confirms that the sensor response to gas is sufficient to provide reliable operation without false indication. If the sensor has low sensitivity, an LED lights to indicate that sensor replacement is due. False Alarm Avoidance During Power-Up and Calibration, the transmitter output is locked at 4 mA. The output remains locked for five minutes directly after power is applied or after calibration gas is removed, allowing sufficient time to fully stabilize before coming on-line. This avoids erroneous readings during warm-up and prevents alarm caused by calibration gas. Convenient Diagnostic Measurements Critical measurements are made at convenient jacks for a Volt Ohm Meter. Each measurement location is clearly marked. All modules have a signal output adjustment. Model 4101 Series Gas Sensor Modules Simple Zero and Span Adjustments Easily accessible potentiometers enable calibration adjustments to be made in minutes by non-technical personnel for reduced maintenance cost. Flexible Alarm and Logging Options The analog gas sensor modules can be used as part of a facility gas risk management plan. The 4-20 mA output signal is ideally suited to interface with a wide range of instrumentation for alarm annunciation and recording. The sensor module is housed in a NEMA-7 enclosure rated for Class 1, Division 1, Groups C, D environments. An optional NEMA 4 Group B enclosure is available. Be sure to also look at the 5100-XX-IT Series Intelligent Gas Sensor Modules for network-enabled hazardous gas monitoring. 4101-16 - 22/27 Sierra Monitor Corp. 1991 Tarob Ct., Milpitas, CA 95035, USA, 408-262-6611, 800-727-4377, FAX: 408-262-9042Web Site: E-Mail: sales@sierramonitor.com Gas Sensor Modules Specifications Gas Type Model Sensor Std. Range 6 Units Resolution Response Time 2 Sensor Life 3 Operating Range oF oC RH Oxygen 5100-03-IT 1 EC 5-25 % Vol. +/-0.1% <10 Sec. 2 Yrs. 5 to 122 -15 to 50 15-99% Carbon Monoxide 5100-04-IT 1 EC 0-500 PPM 0.5 PPM <25 Sec. 2 Yrs. -4 to 122 -20 to 50 15-99% Hydrogen Sulfide 5100-05-IT 1 EC 0-100 PPM 0.1 PPM <30 Sec. 2 Yrs. -40 to 122 -40 to 50 15-99% Chlorine 5100-06-IT 1 EC 0-10 PPM 0.1 PPM <60 Sec. 2 Yrs. -4 to 122 -20 to 50 15-99% Sulfur Dioxide 5100-10-IT 1 EC 0-100 PPM 0.5 PPM <20 Sec. 2 Yrs. -4 to 122 -20 to 50 15-90% Nitrogen Dioxide 5100-12-IT 1 EC 0-20 PPM 0.2 PPM <35 Sec. 2 Yrs. -4 to 122 -20 to 50 15-90% Carbon Monoxide 4 4101-16 EC 0-2000 PPM 0.1 PPM <35 Sec. 2 Yrs. -4 to 122 -20 to 50 15-90% Nitric Oxide 4101-19 EC 0-20 PPM 0.5 PPM <15 Sec. 2 Yrs. -4 to 122 -20 to 50 15-90% Hydrogen Chloride 4101-21 EC 0-20 PPM 0.1 PPM <100 Sec. 2 Yrs. -4 to 122 -20 to 50 15-90% Hydrogen Cyanide 4101-22 EC 0-20 PPM 0.1 PPM <70 Sec. 2 Yrs. -4 to 122 -20 to 50 15-90% Ammonia 5100-25-IT 1 EC 0-50 PPM 1.0 PPM <30 Sec. 5 14 to 122 -10 to 50 20-95% Hydrogen Fluoride 5 4101-26 EC 0-10 PPM 1.0 PPM <30 Sec. 5 14 to 122 -10 to 50 20-95% Ethylene Oxide 4101-27 EC 0-20 PPM 0.1 PPM <90 Sec. 2 Yrs. -4 to 122 -20 to 50 15-90% Notes: 1 5100-XX-IT Series provide intelligent network-enabled hazardous gas detection 2 Response time to 90% full signal value for applied concentration 3 Sensor life typical for use at standard temperature and pressure with occasional exposure to gas of interest 4 Hydrogen tolerent 5 Diffusion via memberane. Requires electrolyte 6 Optional ranges available Electrical Data Loop Type: 3 wire Loop Resistance: 800 Ohm with 28VDC Input Voltage DC: 14-30 VDC Input Current: 40 mA Input Power Max: 1.4W Signal Output: 4-20 mA DC linear (trouble 0 mA) Operating Pressure: +10% (variation from ambient) Mounting: 3/4" NPT Explosion proof (NEMA 7) Housing: (Div. I, Class 1, 2, Groups C, D, E, F, G) Optional NEMA 4 Group B housing available Construction: Modules Dimensions Weight 4101-16-27 H: 8.0", D: 4.5", W: 4.0" 2.7 lb (20.3 x 15.2 x 15.2 cm) (1.3 Kg) 4101-26 H: 10.2", D: 6.0", W: 6.0" 2.7 lb (25.9 x 15.2 x 15.2 cm) (1.3 Kg) Warrenty: Two year on non-consumables 02/10 Sierra Monitor Corp. 1991 Tarob Ct., Milpitas, CA 95035, USA, 408-262-6611, 800-727-4377, FAX: 408-262-9042 Web Site: E-Mail: sales@sierramonitor.com © 2010 by Sierra Monitor Corporation ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias