Log:
Assessments - , GPA: ( )

Instruções de Operação BRK electronic, Modelo CO410B

Fabricante : BRK electronic
Arquivo Tamanho: 745.52 kb
Arquivo Nome :

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


Test button should check all alarm functions by simulating a carbon monoxide condition, causing the unit to alarm. The silence feature is to temporarily silence unwanted alarms. 8. The unit shall be capable of operating between 40° F (4° C) and 100° F (38° C) and relative humidity between 10% and 90%. 9. The unit will alarm at the following CO levels: 70 PPM between 60 and 240 minutes; 150 PPM between 10 and 50 minutes; 400 PPM between 4 and 15 minutes. 10. The unit shall include mounting hardware and shall be listed for wall mounting. Alarm Dimensions Weight Operating Voltage Temperature Range Humidity Range Audio Alarm Test Button Alarm Reset Sensor Indicator LEDs Listing 3.3"Hx4.75"Lx1.5"D 5.5 oz (C0400B) 6.2 oz (C041 OB) Two 1.5V AA Batteries 40°F (4°C) to 100°F (38°Q 10% to 90% relative humidity (RH) 85dB at 10 feet Electronically simulates a carbon monoxide condition, causing the unit to alarm Automatic when carbon monoxide clears; Press Test/Silence button to reset manually Electrochemical DC Power : Red LED flashes once per minute Local Alarm: Audio alarm (4 beeps, pause, 4 beeps) and rapidly flashing Red LED UL 2034 Standard SHIPPING SPECS: C0400B 5.4"Lx1.6"Wx3.4"H 0.43 lbs 0.02 ft3 029054000743 7.4"Lx5.4"Wx6.1"H 6 2.92 lbs ,14 ft’ 60029054000745 45 6 270 49.64 ft3 788.4 lbs. Cube UPC Master Carton Dimensions Master Pack Weight Cube UPC Pallet Information Cases per Layer Number of Layers Cases per Pallet Cube Weight Distributed by: C0410B 5.4"Lx1.6"Wx3.4"H 0.48 lbs 0.02 ft3 029054000972 7.4"Lx5.4"Wx6.1"H 6 3.21 lbs. ,14ft3 60029054000974 45 6 270 49.64 ft3 866.7 lbs. 11. The unit shall at a minimum meet the requirements of UL2034. INSTALLATION OF CARBON MONOXIDE ALARM Installation of this carbon monoxide alarm must confirm to NFPA 720. Always check your local building codes. Follow all instructions for placement as outlined in the user's manual in sections titled "Recommended Locations for Carbon Monoxide Alarms" and "Locations to Avoid for Carbon Monoxide Alarms." * Based on claims of major manufacturers. First Alert Manufactured By: BRK Brands, Inc. 3901 Liberty Street Road Aurora, IL 60504-8122 First Alert® is a registered trademark of the First Alert Trust ©2007 BRK Brands, Inc. All rights reserved CM2795...

Este manual também é adequado para os modelos :
Alarme de incêndio - CO400B (745.52 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias