|
Facilidade de uso
• The SpectraLink 6000 System or SpectraLink 8000 Telephony Gateway is installed and the handsets are available for programming. PN: 1725-36130-001_E.doc LinkPlus Interface Guide: Avaya DEFINITY Communications System DEFINITY Four-Wire Interface The DEFINITY TN754B (any vintage) or TN754 (vintage 11 or higher) circuit pack provides eight, four-wire digital station circuits. Two of these wires are used for transmit, two are used for receive. Typically the stations are wired to a block or to a patch panel. From the block or patch panel the stations are wired to a modular jack. The jack can connect to a short patch cord that connects to the MCU. The following table shows the Avaya side of the block or patch panel wiring. Pair Function 1 2 Receive Station 1 3 Transmit Station 1 4 5 Receive Station 2 6 Transmit Station 2 7 8 Receive Station 3 9 Transmit Station 3 10 11 Receive Station 4 12 Transmit Station 4 13 14 Receive Station 5 15 Transmit Station 5 16 17 Receive Station 6 18 Transmit Station 6 19 20 Receive Station 7 21 Transmit Station 7 22 23 Receive Station 8 24 Transmit Station 8 25 PN: 1725-36130-001_E.doc Interface Implementation See the documentation for your SpectraLink components for more information about wiring the demarc block or patch panel. The following table shows the patch cord pinout for the Avaya side of the modular 8-pin (RJ45) connector. Pin Function 1 Receive 2 Receive 3 Transmit 6 Transmit Each digital pair is polarity insensitive. If you reverse polarity the system will still work. Set the Switch Interface Type SpectraLink 6100 MCU The SpectraLink 6100 Master Control Unit (MCU) requires the switch interface type to be configured using the front panel buttons. The configuration procedures are detailed in the SpectraLink 6100 MCU: Installation and Operation document. SpectraLink 6300 MCU When configuring the SpectraLink 6300 MCU, the PBX interfaces are available as sub-menu selections when defining the Interface Module type using the SpectraLink 6300 MCU Operator’s Console. Refer to the SpectraLink 6300 MCU: Operator’s Console document for details on configuring the Interface Modules. SpectraLink 8000 Telephony Gateways Connect to the SpectraLink 8000 Telephony Gateway using the serial or modem interface. From the Main Menu, choose Gateway Configuration. Scroll to Telephone Switch Type and press enter to change this field, from the Submenu of PBX types, select DEFINITY. Refer to the SpectraLink 8000 Telephony Gateway: Administration Guide for SRP document for details on configuring the Telephone Switch Type. PN: 1725-36130-001_E.doc LinkPlus Interface Guide: Avaya DEFINITY Communications System Key-mapping the Handset to Emulate 8410D Functionality Programmable buttons on Page 2 of the station form can be assigned as determined in the pre-installation procedures. The following diagram shows how the 8410D buttons map to the handset. FCN 1 MUTE HOLD FCN 4 DROP FCN 3 CONF FCN 2 XFER FCN*1 FCN*2 FCN*3 FCN*4 Menu PREV NEXT FCN*5 FCN*6 FCN*7 FCN*8 EXIT LINE 6LINE 1 FCN 5 LINE 2 LND FCN 6 LINE 3 ABDIAL FCN 7 LINE 4 VMAIL LINE 5 FCN 8 CALLBK DEFINITY 8410D Key-mapping The FCN [number] and LINE [number] labels represent the key sequence on the handset mapped to the corresponding key on the desk set. The FCN * sequence is used to map to softkeys. Pressing the FCN key on the handset followed by the * key and the [number] key PN: 1725-36130-001_E.doc Interface Implementation is the sequence equivalent to pressing the corresponding softkey on the desk set. The handset function menu default settings are shown on each corresponding button in the above diagram; these may be changed as described above in Function Menu Programming. Some of these functions (Mute, Redial, Forward, etc.) are activated by softkeys or FCN menu options on the SpectraLink 6000 and SpectraLink 8020/8030 Wireless Telephones. FCN + 1 MUTE FCN + 2 XFER FCN + 3 CONF FCN + 4 DROP FCN + 5 LND FCN + 6 ABDIAL FCN + 7 VMAIL FCN + 8 CALLBK FCN + 9 EXIT MENUS Program DEFINITY Each handset must be administered on the DEFINITY so the switch will recognize the handset and allow access to system facilities and features. The DEFINITY technician or local system programmer should perform the necessary programming. Save translations Before beginning to program the system, the technician may want to back up the current programming with the save translations command. This will take time, but will ensure that translations can be restored if necessary. Program Handsets Copy settings from a wired set The easiest way to program the SpectraLink Wireless Telephone on DEFINITY is to find a wired 8410D station that has settings and restrictions similar to what is required for the handset, and use the duplicate station command to copy those settings to a “template” handset. If there is no 8410D available, find a station that has similar settings, and use the display or print station command to check the PN: 1725-36130-001_E.doc LinkPlus Interface Guide: Ava...
Este manual também é adequado para os modelos :Impressoras - AVAYA DEFINITY LINKPLUS SPECTRALINK 6000 (151.93 kb)
Impressoras - AVAYA DEFINITY LINKPLUS 1725-361300-001 (151.93 kb)