Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Cleveland Range, Modelo HA-MKGL-100-CC-T

Fabricante : Cleveland Range
Arquivo Tamanho: 2.62 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


FEET ARE ADJUSTABLE TO +1" MAXIMUM. MANUFACTURER MUST BE NOTIFIED IF UNIT WILL BE OPERATING ABOVE 2000' ALTITUDE. CONSULT FACTORY FOR MANUFACTURED GAS. Cleveland Range reserves right of design improvement or modification, as warranted. OPERATING INSTRUCTIONS NOTE: Location of switches may vary dependant on customers specific options Red Low Water Indicator Light When lit, in the upright position, indicates kettle gas burner has cut out and unit requires more water. Occasional pulsing of this light is normal. Green Heat Indicator Light When lit, indicates gas burner is on; cycles on-off with solid state controls. Solid State Temperature Control Knob / On-Off Toggle Switch Controls electrical power to kettle. and allows operator to select kettle heat increments from minimum, 1-10. A setting of 7 or higher will boil water Amber Ignition Failure Indicator Light Indicates failure of heating system to ignite (Used prior to July 2004) Agitator Stop Button Stops agitator in case of emergency Agitator Start Switch Starts agitator. Agitator power control switch must be ON Agitator Power Switch Allows power to agitator. When not in use, turn control power OFF Agitator Speed Control Switch Turn clockwise until desired speed is reached Power tilt control switch Tilts kettle for pouring; some kettles have manual hand tilt Reset circuit breaker Protects power tilt system from overload. Push to reset 0 0123 Water Meter Digital Counter (not shown) Location may vary dependant on customer's specific options Fill Interrupt Switch (Q'-'"'"- Interrupts water fill cycle Potable Fill Water Switch Selects hot or cold water Fill Cycle Switch Start/continue cycle switch Product Discharge Valve Switch Toggle momentary switch to desired valve opening Temperature Sensor Senses temperature of product Automatic Dump Valve Empties kettle of either food product or wash water Sight Glass For checking water level of kettle jacket Vacuum /Pressure Gauge Indicates steam pressure inside steam jacket in PSI, as well as vacuum in inches of mercury Gas Shut-Off Valve Air Quick Connect Push yellow tab down to release air pressure before disconnecting air hose Kettle Filler Nozzle B General WARNING: Do not attempt to operate this appliance during a power failure. Keep appliance and area free and clear of combustibles. Before turning kettle on, ensure that following conditions exist: • If you are cooking an egg or milk product, do not pre-heat kettle. • The vacuum/pressure gauge needle is in green zone; if it is not and is in "vent air” zone, call your service agent to repair leak. • The electrical service to kettle is turned on NOTE: The kettle should be sanitized prior to the daily production run - see CLEANING INSTRUCTIONS . Mixing ("AGITATOR ") WARNING: • Never add product to kettle while agitator is running. • Do not put hands in kettle. • Watch for loose clothing near agitator. 1. Turn "SPEED CONTROL" to "0". 2. Switch agitator to "ON". 3. Push agitator "START" to initiate mixing. 4. Turn "SPEED CONTROL" to desired mixing speed 5. To stop mixing action, push agitator stop button. NOTE: Mixing speed depends on the product consistency. The faster the mixing speed the more damage may be done to fragile product. Heating (General Notes) • The green light cycles on and off, indicating that burners are cycling to maintain set temperature. • The red "low water" light should not be lit during operation. This light indicates that water level is critically low and that gas burners have automatically shut off. Before further use, refer to RESERVOIR FILL INSTRUCTIONS for adding distilled water. • Occasional flashing of the red "low water" light is ok while kettle is heating. Manual Heating 1. Switch "POWER" to "ON". 2. Turn temperature control knob to desired setting. 3. Switch "CONTROLLER" to "BYPASS". 4. After closing discharge valve, place product in kettle. Automatic Heating 1. Switch "CONTROLLER" to "ACTIVE". 2. Turn temperature control knob to "10". 3. Continually push function key " " until "OFF" is displayed. 4. Push and hold key " 4. " or " -f- " until desired temperature is set. 5. To Start: push function key " 0 " until "CtrL" is displayed. 6. Push down key " 4. ". 7. To Stop: push function key " t) " until "OFF" is displayed. 8. Push down key " 4 ". 9. After closing discharge valve, place product in kettle Emptying the Kettle 1. To open automatic dump valve: • Turn PRODUCT DISCHARGE VALVE switch clockwise to JOG TO OPEN. Release switch to the HOLD position when desired valve opening is achieved. • To close valve, turn switch counterclockwise to CLOSED position. 2. To avoid splashing, slowly empty kettle contents into an appropriate container by partially opening dump valve. NOTE: When pumping with a Metering Filling Station the speed of the agitator arm must be sufficient to suspend the heavier items in the mix in order to achieve an even distribution i...

Este manual também é adequado para os modelos :
Outros aparelhos de cozinha - HA-MKGL-100-CC (2.62 mb)
Outros aparelhos de cozinha - HA-MKGL-100 (2.62 mb)
Outros aparelhos de cozinha - HA-MKGL-100-T (2.62 mb)
Outros aparelhos de cozinha - HA-MKGL-60 (2.62 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias