Fabricante : Follett
Arquivo Tamanho: 3.69 mb
Arquivo Nome :
|
Facilidade de uso
Do not mount directly onto runners or channels. • There must be no lip or edge that would hinder the icemaker from sliding in or out of the louvered docking station . INTAKE AND EXHAUST GRILLE PLACEMENT: Horizon 1000 & 1400 air-cooled models only (See detail drawing on page 9) • Position the intake grille cut out in the access panel/door Note: Icemaker must be aligned with cut out and inside of access panel to provide a tight seal and prevent recirculation of hot exhaust air. • Left edge of cutout should be 1.75" (45mm) from the left side of the icemaker . • Bottom edge of cutout should be 1.875" (48mm) from the bottom of the icemaker . • Position supplied exhaust grille at least 18" (458mm) away from intake grille .. Where possible, install exhaust grille to the rear or side of the base cabinet. • If not using supplied grille, air circulation requirements below must be met: 1000 series: 150 sq. in (967 sq cm) intake air, 150 sq. in (967 sq. cm) exhaust air 1400 series: 175 sq. in (1129 sq. cm) intake air, 175 sq. in (1129 sq. cm) exhaust air 4.1 Undercounter installation requirements Horizon 1000 & 1400 series WARNING • Docking station must be secured in accordance with these instructions to ensure icemaker stability. • Ventilation openings in the louvered docking station should be clear of obstruction Wall bracket accessory Machine stand accessory • Mount louvered docking assembly to wall bracket accessory • Mount louvered docking assembly to machine stand accessory DROP-IN • SATELLITE-FILL self-contained 9 CROSSBRACE Front View 3D Counter View Top View Access panel/ door on counter 1.75" (45mm) bottom of ice machine side of ice machine 1000 series - 12"x16" cutout (305x407mm) 1400 series - 16"x16" cutout (407x407mm) 1.875" (48mm) 1000 series - 12" (305mm) 1400 series - 16" (407mm) 16" 18" min. (407mm) (458mm) 1000 series - 28.6" min. (727mm) 1400 series - 31.6" min. (303mm) 24.5" min. (623mm) No Lip . . . . . 1.75" (45mm) CROSSBRACE Undercounter installation detail – Horizon 1000 & 1400 series CAUTION • Keep ventilation openings in the appliance enclosure clear of obstruction. • To ensure proper ventilation (if not using supplied grille) carefully review air circulation specifi cations on facing page (4.1) 10 self-contained DROP-IN • SATELLITE-FILL Ice transport tube Install the ice transport tube. 5 208264 Stock Module Identification Plate Service No. Module No. Product OMRESSOR THERMALLY PROTECTED Easton Pennsylvania AMPS AMPS VOLTS PHASE SINGLE CHARGE LOW SIDE PART NO PSIG THE USA MADE IN OZ R C R HZ UL L NSF U Hot Water . 1/4. 1' . . . . . . Ice transport tube tips • Insulate entire length of ice transport tube . • Secure ice transport tube . as needed to prevent dips and traps from forming. For long tube runs see guide on page 16. • Pitch tube at least 1/4" per foot (6,4mm/.3m) . • Ice transport tube must drain towards icemaker Ice transport tube to Icemaker • Be sure tube ends are square . • Soften ice transport tube with hot water (160 ...
Este manual também é adequado para os modelos :Outros aparelhos de cozinha - Horizon HCC1000AJS (3.69 mb)
Outros aparelhos de cozinha - Horizon HCE1400AJS (3.69 mb)
Outros aparelhos de cozinha - Horizon HCE1400WJS (3.69 mb)
Outros aparelhos de cozinha - Horizon HCC1400AJS (3.69 mb)