Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Kambrook, Modelo Aquarius KAK36

Fabricante : Kambrook
Arquivo Tamanho: 117.92 kb
Arquivo Nome : 78d1b592-722a-3524-6de7-2f21731126ee.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Do not operate unless the element is fully immersed. Do not move appliance while switched on. Regularly inspect the cord, plug and actual appliance for any damage. If found damaged in any way, immediately cease use of the appliance and return the appliance to the nearest authorised Kambrook Service Centre for examination, replacement or repair. Please call 1800 800 634 for Service Centre details. 2 Features of your Kambrook Aquarius Kettle (KAK36) 1857231. Hinged lid opens for easy filling and cleaning 6. Full length Water Window - 1.7 litre capacity full-length water 64 2. Illuminated on light indicates power on when boilling 3. On / Off boil switch with automatic cut off 4. Fine mesh scale filter to prevent scale build up from entering your beverage 5. Safety Boil Dry Feature ensures that the kettle automatically switches off if kettle boils empty window gives fast reference to water level. 7. Cool touch handle is comfortable to use and suitable for all hand sizes 8. Cordless base for ease of use, filling and cleaning (KAK36 only) 9. Fast Boil for easy re-boiling of warm water (KAK35 not shown) 3 Using Your Kambrook Aquarius Kettle Before first use of your new Kambrook Aquarius Kettle, clean the element and internal section of the container by boiling the kettle full, following the instructions below, and then discard water. NOTE:The Kambrook Aquarius Kettle (Model KAK36) must only be used with the power base supplied. To fill the kettle, open the lid by pulling up on the handle on the lid. Fig 1 Do not fill above the max water level line or below the minimum water level line marked on the water window. Do not overfill the kettle as this may result in boiling water being splashed out and too little water will result in the kettle switching off before the water has boiled. Place the kettle (or cordless base and kettle) on a level, flat surface. Ensure that the lid is locked firmly in place and then place the kettle securely onto the power base (KAK36 only). Connect power cable supplied to appliance (KAK35 only). Important: Make sure this plug is firmly inserted into socket. Connect 3 pin 230/240V plug to power supply. Turn power on. Push the On/Off switch up, located at the base of the handle.The 'on' light will illuminate indicating that the kettle is boiling water. Once the water is boiled the kettle will automatically switch off. For KAK35 corded kettle, switch power off at the power outlet and remove plug from power point and then from kettle before pouring water as required. For KAK36 cordless kettle switch off at the power outlet and then lift the kettle from the power base and pour as required using the handle. Take care to hold the kettle level especially when filled to the maximum level. Kettle can be returned to cordless base when not in use. Ensure that the power is switched of at the power outlet when the kettle is not in use. NOTE: Use caution when pouring water from your kettle, as boiling water will scald. Do not pour the water too quickly. 4 CAUTION: Do not operate on an inclined surface. Do not operate unless the element is fully immersed. Do not move while switched on. Failure to observe these cautions may result in damage to the kettle. Maintaining Your Kambrook Aquarius Kettle Safety Boil Dry System Your Kambrook Aquarius Kettle is fitted with a safety device that protects against overheating should the kettle be operated with insufficient water. In this instance, the kettle will immediately cease heating.This feature will turn the kettle off and allow the kettle to cool before further operation.The device will automatically reset itself when the unit has cooled sufficiently. Thermal Cut-out This feature has been built into your Kambrook Aquarius Kettle. In the event that your kettle does malfunction this feature will prevent overheating.This safety feature will automatically shut down the kettle to prevent further damage (and usage). If this does occur, please take your kettle to an authorised Kambrook Service Centre. Cleaning Always switch off at the power outlet and then unplug before cleaning, moving or storing the appliance. WARNING! NEVER IMMERSE THE KETTLE, POWER BASE, CORD OR PLUG IN WATER OR ANY OTHER LIQUID Additionally ensure that moisture does not come into contact with cords, plugs, kettle or power base. Interior Cleaning Removal of Mineral Deposits Mineral deposits in the water may cause the kettle interior to discolour. This may be removed using a Kettle De-Scaler available form most supermarkets and hardware stores. Alternatively you can make your own solution. Fill the kettle with 3 cups of white vinegar and the remainder with water and allow to stand overnight. DO NOT BOIL. Empty the solution from the kettle. Fill the kettle again with clean water, bring to the boil and discard water. Repeat and the kettle will then be ready for use. Exterior Cleaning Always ensure that the power is switched off and unplug the kettle from the power outlet prior to cleaning. The exterio...

Este manual também é adequado para os modelos :
Outros aparelhos de cozinha - Aquarius KAK35 (117.92 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias