|
Facilidade de uso
INC. Peachtree Citv GA Refer to the NAMEPLATE for electrical specifications. A Nameplate is located on the upper RIGHT side of the dispenser's Rear Panel. It cannot be read when the back of the dispenser is against a wall or is otherwise inaccessible. Therefore, the necessary electrical information is also on an additional label, which can be easily seen by removing only the Front Panel of the dispenser. We reserve the right to make specification and design changes without prior notice. A5BA10B9506 4 A5AA10B9505 PUSH BUTTON (ICE) 2. DIMENSIONS/CONNECTIONS А5ВА10В9505 [b] DM-180A6 PUSH BUTTON (ICE) (OPTION) DISPENSER DRAIN (3/4" FPT) .SZ9'7 ' ^ 8V08H/\IQ[o] 32.50' 3.50- . . 16.875' О. О S ■ oo о > X il. INSTALLATION AND OPERATING INSTRUCTIONS -IMPORTANT- Only qualified service technicians should attempt to install, service or maintain the dispenser. No such installation, service or maintenance should be undertaken until such technician has thoroughly read this Instruction Manual. 1. CHECKS BEFORE INSTALLATION NOTICE ■ For optimum beverage dispensing performance, HOSHIZAKI recommends the use of a fast flow carbonator. • Remove all tape, packing material, and shipping cartons from ice dispenser, to prevent possible damage to the machine. • Remove the accessories package from the dispenser. • Remove the protective films from the side panels. If the ice dispenser has been exposed to sunlight, or to direct heat, the exterior panels should be allowed to cool before removing the protective films. • Refer to the NAMEPLATE, located on the upper RIGHT side of the Rear Panel. Be certain that the voltage supply corresponds with the voltage specified on the nameplate. 9 A5BA10A9501 2. LOCATION -NOTICE- This ice dispenser is not intended for outdoor installation. The air temperature should be within a 45°F to 100°F range. Extended periods of operation at temperatures exceeding these limitations may cause unsatisfactory results. Position the ice dispenser in a selected site. • Place the machine on a flat, solid (firm) location. • Be sure the air temperature range at the location is between 45° F and 100° F. • Keep the unit away from ovens, grilles or other high heat producing equipment. • It is recommended that the dispenser be located near a drain, and in a location where water cannot collect on the floor. • Always avoid an installation site where dripping is not allowed. • Allow a minimum clearance of 24 inches (60 cm) above the ice dispenser for easy filling with ice. • If the ice dispenser is to be permanently installed, allow a minimum clearance of 6 inches (15 cm) on the right side, for access to service the drive mechanism. A5BA10A9501 10 3. SET UP -NOTICE- It is extremely important that the ice dispensing bin be leveled in both the left-to-right, and the front-to rear directions. If it is not level, unsatisfactory performance in beverage cooling and/or a reduced rate of ice flow may result. 1) Unpack the ice dispenser, and remove all shipping cartons, tapes and packing BEFORE operating the unit. Attach the four (4) (optional) adjustable legs to the bottom of the ice dispensing bin. The legs are adjustable from a minimum of 4 inches (102 mm) to a maximum of 5 inches (127 mm). Be careful not to damage the exterior panels when handling the ice dispenser. 2) Position the ice dispenser in a selected site. Clean the interior with soap and water and rinse thoroughly. 3) Level the ice dispenser in both the left-to-right and the front-to-rear directions (when installed with or without legs). 4) When installing the unit without legs, the perimeter where the machine touches the counter should be sealed with silicone to prevent water from leaking under the ice dispenser. The right side panel should be removed prior to applying the silicone, so that it can be easily removed later if drive mechanism inspection and/or service becomes necessary. 4. ELECTRICAL CONNECTION This ice dispenser requires a proper electrical ground that meets the national and local electrical code requirements. ONLY plug it into a 115 volt, 15 amp outlet with a grounding connection (115V /15Amp / 60Hz). Refer to the NAMEPLATE for the proper electrical specifications. -CAUTION- The GREEN grounding wire in the factory-installed power cord is attached to a screw on the frame. If it becomes necessary to remove or replace the power cord, be sure to attach the ground wire of the cord to this screw on the frame. 11 A5BA10A9501 5. DRAIN CONNECTION (Refer to Fig. 1) 1) A 3/4" female pipe thread drain outlet is located at the rear of the ice dispenser. 2) All horizontal runs of drain pipe must have a 1/4 inch drop per foot to promote good drainage. See the Drain Connection diagram (Fig. 1). 3) Drains should not be piped directly to a sewer system. An air gap of a minimum of 2 vertical inches should be between the end of the ice dispenser drain pipe and...
Este manual também é adequado para os modelos :Outros aparelhos de cozinha - DM-180A (591.01 kb)
Outros aparelhos de cozinha - DM-180A8 (591.01 kb)
Outros aparelhos de cozinha - DM-180AX (591.01 kb)