Log:
Assessments - 0, GPA: 5 ( )

Instruções de Operação Bradley Smoker, Modelo HN-400

Fabricante : Bradley Smoker
Arquivo Tamanho: 234.37 kb
Arquivo Nome : sh781.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. . . . . . . . . . . . . .2 HN-200 Column Shower Components and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .2 Installation Instructions Type AColumn Shower . . . . . . . . . . . . . . . . . .3 Supplies from Below/Vent Off Line Type B Column Shower Installation . . . . . . . .4 Supplies from Above/Vent Through Column Type H Column Shower Installation . . . . . . . .5 Supplies from Below/Vent Through Column Type O Column Shower Installation . . . . . . . .6 Supplies from Above/Vent Off Line Optional Shroud Installation . . . . . . . . . . . . . . . .7 Cleaning Instructions . . . . . . . . . . . . . . . . . . . . .9 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 IMPORTANT: Before beginning installation, all supply, drain and waste piping to the shower must be completed according to the rough-ins received with the drain assembly. Check the local codes and ordinances in your area for proper location and connection requirements. Conformity to local codes is the responsibility of the installer. Read and save this installation manual, which contains maintenance and repair information, for future reference. 215-781; Rev. D; EN 03-310 P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL: 1-800-BRADLEY FAX: (262) 251-5817 © 2003 Bradley Corporation Page 1 of 9 12-16-2003 42" (1067 mm) TO FLOOR 48" (1219 mm) TO FLOOR INLINE BACKFLOW PREVENTER 169-988 QUICK DISCONNECT 169-939 SUPPLY ELBOW 169-941 GRAB BAR S53-039 HOSE 169-937 HOSE SPRAY 169-936 MOUNTING POST S70-078 SWIVEL CONNECTOR 169-943 DIVERTER S45-323 SOAP TRAY 126-005A 2 Bradley Corporation • 215-781 Rev. D; EN 03-310 Barrier-Free Column Shower HN-400 Installation Instructions 12-16-2003 Pre-Installation Information Overview The Bradley HN-400 Barrier-Free Column Shower features one station that is adapted for use by the handicapped. Valve and showerhead height for all wash stations, including the handicapped station, measures 42" (1067 mm). Components Material: Column showers are constructed of 16-gauge, type 304 stainless steel. The base flange is 14-gauge stainless steel. All exposed stainless steel parts are #4 finish. Exterior brass components are polished and chrome-plated. Handicapped Station: The handicapped station includes a grab bar, diverter valve, hand-held shower with bracket, in-line backflow preventer, and quick disconnect (see shower components and dimensions shown below). HN-400 Column Shower Components and Dimensions Supplies required for installation: • Supply piping to column’s 3/4" type “L” copper tubing • 2" NPT vent pipe (for type B and type H drains only) • (5) 5/16" screws (for shroud slip ring installation) Barrier-Free Column Shower Installation Instructions HN-400 Installation Instructions for Type A HN-400 Column Shower Step 1: Install column shower components NOTE: Flush supply lines before making connections. 1. Remove the five bolts that secure the disposable washer to the drain and lift the disposable washer off. 2. Bolt the column shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 1). Step 2: Connect water supply 1. Remove the two 1/4"-20 screws from the access panel on the lower body of the column shower and lift the panel off. 2. Through the access opening, connect water supplies to the shower’s 3/4" copper tubing as shown in Figure 2 (piping supplied by installer). 3. Turn on water to the shower and test for leaks and adequate water flow. 4. Replace the access panel onto the shower with 1/4"-20 screws provided. NOTE: For column shower drains with a dome grate drain, install the two halves of the grate with the screws provided after the column installation is complete. (5) 5/16"-18 HEX-HEAD BOLTS 160-092 (5) WASHERS 142-034 Figure 1 Figure 2 Supplies from Below/Vent Off Line Bradley Corporation • 215-781 Rev. D; EN 03-310 12-16-2003 Barrier-Free Column Shower HN-400 Installation Instructions Installation Instructions for Type B HN-400 Column Shower Step 1: Install column shower components NOTE: Flush supply lines before making connections. 1. Remove the five bolts that secure the disposable washer to the drain and lift the washer off. 2. Loosen the screw(s) securing the shower cover and lift the cover off. DO NOT remove the screw(s)! 3. Insert a 2" NPT vent pipe (supplied by installer) into the shower. NOTE: Make sure that vent pipe does not snag internal wiring or come in contact with electronic components. 4. Position the shower over the drain and screw the 2" NPT vent pipe into the vent connection (see Figure 4). 5. Bolt the shower to the drain with the five bolts (removed in procedure #1) and oval washers provided (see Figure 1). Step 2: Connect water supply 1. Drop the supplies to the top of the column shower. (5) 5/16"-18 HEX-HEAD BOLTS 160-092 (5) WASHERS 142-034 Figure 3 2. Slide the column cover up the vent and supply piping. NOTE: If you are installing a column shroud, slide the slip ring up the ven...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias