Log:
Assessments - 5, GPA: 4 ( )

Instruções de Operação ProForm, Modelo PFHS60070

Fabricante : ProForm
Arquivo Tamanho: 873.95 kb
Arquivo Nome : f56c390c-e69f-496e-a88b-57c2ba9b4fcd.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


TESTING AND TREATING THE WATER The RESTORATION 600 comes with a starter chemical pack for maintaining the water in the spa. Disregard the directions on the individual packages of OQUICK pHix It DOWNO and OQUICK pHix It UP.O However, the directions on the bottle of ONon-chlorine ShoxO and OBromine BaseO are correct. Always keep the chemicals away from children and pets. The first time you use the spa, you should test and treat the water. Once you have verified that the spa jet unit is functioning properly, and have allowed the water to circulate for a while, you should remove the spa cover and add 1/3 of the OBromine BaseO bottle, 10 and 1/3 of the ONon-chlorine ShoxO bottle to the water in the spa. Allow the water to circulate for five minutes. You should now test the pH level of the water. Use the included test strips to check the pH of the water. Refer to the instructions on the test strip packaging to see how to use the test strips. If the level is too low, add half of one of the OQUICK pHix It UPO packets to the water. Let the water circulate through the spa jet unit for five minutes. Test the pH level again. Repeat until the pH level is correct. If the level is too high, add half of one of the OQUICK pHix It DOWNO packets to the water. Let the water circulate through the spa jet unit for five minutes. Test the pH level again. Repeat until the pH level is correct. Replace the spa cover and allow the water to continue to heat. See WATER CHEMISTRY on page 13 for information concerning proper water maintenance. SECURING THE SPA COVER The spa cover can be secured by snapping the latches on the spa cover into the buckles on the side panels. The buckles can be locked by inserting the key and turning it clockwise a quarter turn. To unlock the buckles, insert the key and turn it counterclockwise a quarter turn. Key Latch Buckle Always keep the buckles locked when the spa is not in use. Keep the keys in a safe place, out of the reach of children. DIAGRAM OF THE CONSOLE USING THE CONSOLE Refer to the console diagram above. The function of each console control is explained below: Primer: This opening allows you to prime the spa jet unit before operation (see PRIMING THE SPA JET UNIT on page 10). Thermostat: Controls the temperature of the water. The water heats at about 1.7.F an hour with the cover on. The thermostat can be set to heat the water from 70.F to 104.F. Use a medical or other accurate thermometer to check the temperature of the water. On/Off: Turns the spa jet unit on and off. When you first press the on/off button, the spa jet unit will run at low speed, providing gentle hydrotherapy. Press the button again and the spa jet unit will run at high speed, providing more intense hydrotherapy. Press the button a third time and the spa jet unit will shut off. The spa jet unit also features an automatic mode, which heats and filters the water when the spa is left unattended. When the spa jet unit is first plugged in, or if the buttons on the console have not been used for longer than twenty minutes, the automatic mode will begin filtering or heating the water, as needed. Note: to keep the filter and heat cycles from running, the power cord must be unplugged. Air Control: Determines the amount of air that is in the spa jet system during operation. If the control is turned to the left, the amount of air flowing through the jets will increase. If the control is turned to the right, the amount will decrease. 11 SPA JET UNIT OPERATION The spa jet unit features three hydro-therapy jets, a whirlpool jet, a suction vent, and a filter housing. The three hydro-therapy jets (A), located on the front of the spa jet unit, focus the water massage on your neck and back. A B D C The whirlpool jet (B), located on the left side of the spa jet unit, directs the flow of the water to create a whirlpool action in the RESTORATION 600. The suction vent (C), located on the right side of the spa jet unit, pulls the water into the spa unit, in order to operate the system. The suction cover should always be in place over the suction vent. Never operate the spa without the suction cover in place. The filter (D), is located on the left side of the spa jet unit, behind the filter cover. The filter can be removed for cleaning and replacement by removing the Filter Cover and the two filter cover screws and then pulling the filter from the spa jet unit. C Filter Cover Screws Filter Cover D ing the water for twenty minutes to filter any impurities. Also, if the water temperature falls below 40.F, the pump will begin circulating and heating the water to prevent the water from freezing. DRAINING THE RESTORATION 600 To drain the RESTORATION 600, you must use a garden hose to siphon the water. Place one end of the hose in the spa and hold it in front of a hydrotherapy jet until there is a flow of water coming out of the hose. Turn off the spa unit and unplug the power cord. The unit will be damaged if it is run without water circulating. Be sure t...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias