|
Facilidade de uso
MODEL SPECIFICATIONS Model Number Description Voltage Volts Rated Power Watts Remote Control Wall Thermostat Refractory Brick Look AMPS No Heat 120 Volt AMPS 120 Volt AMPS 208 Volt AMPS 240 Volt BF33ST 33” Standard 120/120/208/ 240 245/1440/2100/ 2700 Option Option N/A 2.0 12.0 10.10 11.25 BF33DX 33” Deluxe 120/120/208/ 240 245/1440/2100/ 2700 Option Option Included 2.0 12.0 10.10 11.25 BF39ST 39” Standard 120/120/208/ 240 245/1440/2100/ 2700 Option Option N/A 2.0 12.0 10.10 11.25 BF39DX 39” Deluxe 120/120/208 /240 245/1440/2100/ 2700 Option Option Included 2.0 12.0 10.10 11.25 BF45ST 45” Standard 120/120/208/ 240 245/1440/2100/ 2700 Option Option N/A 2.0 12.0 10.10 11.25 BF45DX 45” Deluxe 120/120/208/ 240 245/1440/2100/ 2700 Option Option Included 2.0 12.0 10.10 11.25 NOTE: Power ratings shown include the light bulbs and motors (275 watts) WARNING The installation of the fireplace unit must comply with the applicable Local and/or National Electrical Codes and utility requirements. This installation should be entrusted to duly qualified personnel where required by law. STEP-BY-STEP INSTALLATION (Note: Please read all instructions before installing) 1. Rough in framing opening following the recommended dimensions located in (Section A: Framing). 2. Allow 8” of service cable for connecting power supply wire to junction box on fireplace when installing before finishing wall. Allow up to 4 feet of service cable for connecting power supply wire to junction box on fireplace when installing after finishing wall. Remove the outer jacket and strip the individual conductors .” from the end. 3. Loosen the screw securing the junction box cover and remove the cover. 4. Remove knockouts if necessary or use the provided cable clamp. 5. Place unit in position in the framed opening, level with shims if necessary and attach unit to frame using mounting flanges provided (see figure 3 on page 3). 6. Unit is factory wired for 208/240 volt power supply (see figure 1 on page 3). If 120 volt operation is required, slide the switch and reconfigure the wiring (see figure 2 on page 3). Wires L1, L2, N & G are attached to the rear of the junction box cable clamp for easy access. Note If wiring unit to operate with NO heat a dedicated circuit may not be required. 7. Wire a dedicated, properly fused circuit with a 15amp rating for the appropriate voltage (120, 208/240). (see Section C for factory setting wiring) 8. Make wall switch and or wall mounted thermostat connections as outlined in Section D: Wiring. 9. Place all connectors inside the unit and secure the junction box cover to unit. Ensure that the cable clamp grips only the jacket of service cable, thermostat and if applicable wall switch lines. 1 WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) SECTION A: FRAMING Dimensions This fireplace is a zero clearance design. No combustibles can be placed on the top surface of the fireplace. Combustibles may be installed to the edge of the unit. Four mounting flanges on the sides of the unit are provided to facilitate installation. Insulation and vapor barrier should be placed a minimum of 2 inches from the unit. SECTION B: RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS For 120 volt installations use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the incoming power supply on fireplace inserts. Use the appropriate wire to meet local and national electrical codes for rated power consumption. For 208 / 240 volt installations use three conductor, non-metallic sheath cable with ground wire (4 wires total) for the incoming power supply on fireplace inserts. Use the appropriate wire to meet local and national electrical codes for rated power consumption. Two conductor, non-metallic sheath cable with ground wire (3 wires total) is recommended for installation of a wall mounted thermostat and/or wall switch for use on fireplace inserts. Use appropriate wire to meet local and national electrical codes for rated power consumption. All wire gauges should match the recommended wire sizes shown below. RECOMMENDED WIRE AND FUSING REQUIREMENTS VOLTS WIRE GAUGE FUSE RATING 120 VOLT 12 GAUGE 15 AMP 208 VOLT 12 GAUGE 15 AMP 240 VOLT 12 GAUGE 15 AMP MODEL A B C D E F G H I J K L BF33ST/DX 15.0” 33.5” 29.5” 23.0” 14.3” 29.6” 32.8” 18.8” 28.5” 48.0” 34.0” 34.0” BF39ST/DX 16.0” 39.5” 33.5” 26.6” 15.3” 36.0” 38.7” 22.8” 32.7” 54.0” 38.0” 38.0” BF45ST/DX 16.0” 45.5” 33.5” 26.6” 15.3” 42.0” 44.7” 22.8” 32.7” 60.0” 42.0” 42.0” Rough-in framing dimensions Rough-in corner framing Top Surface Air Intake Slots Firebox dimensions 2 VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner. CAUTION: When changing the voltage selector switch from 240 volts to 120 volts ens...
Este manual também é adequado para os modelos :Outros acessórios para a casa - BF39ST/DX (807 kb)