Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Axor, Modelo 34133XX1 34213XX1

Fabricante : Axor
Arquivo Tamanho: 2.26 mb
Arquivo Nome : aruh0107.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


120.. - 140.. F* Max. hot water temp 165..F* Hole size in mounting surface valves 1-1/4" spout 1 3/8" Max. mounting surface depth 1 3/8" Flow rate 2.2 gpm *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. Installation Considerations For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber. Please read over these instructions thoroughly before beginning installation. Make sure that you have all tools and supplies needed to complete the installation. This faucet can be used with a continuous flow water heater if the flow pressure is at least 20 psi. For best service, the hot and cold supplies should be at equal pressure. This faucet requires 1/2" supply lines (not included). Installation Install the friction washer and fiber washer on the valve. Push the valve up through the hole in the mounting surface. Install the sealing ring, escutcheon, and nut. Rest the valve assembly on the mounting surface (1). Tighten the screws (2). Push the handles into place (3). Push the spout shank up through the mounting surface (1). Install the sealing ring, escutcheon, and shaft fastening ring (2). The notch on the shaft fastening ring and the notch on the shank must face away from the basin. Install the fiber washer, friction washer, and mounting nut (3). Tighten the mounting nut. 3 2 1 2 1 3 Check the alignment of the handles. If one is not aligned, pull it off (1), turn it slightly (2), and reinstall it (3). Install the glide ring and the o-ring. 2 3 1 Lubricate spout the o-ring. Push the spout into place. Tighten the spout screw with a 2 mm Allen wrench. Tighten the mounting nut screws. Install the drain pull rod. Thread the connecting hoses into the spout shank by hand. Connect the hoses to the valves with the compression fittings. Tighten the fittings using two wrenches. Do not allow the hoses to twist. Install the hot and cold supply lines (not included). Install the pop-up drain. on off Install the pop-up drain Remove the plunger assembly. Unscrew the drain outlet flange from the tee. Unscrew the tailpiece from the tee. Wrap the threads with plumbers’ thread tape and replace. Install the white, flexible sealing gasket to the flange. Place it in the sink outlet. From under the sink, install the black mack gasket, white friction ring and retainer nut to the flange. Do not tighten the nut against the bottom of the sink at this time. Thread the tee and tailpiece to the flange. The pivot must face the faucet. If necessary, turn the drain assembly. Tighten the retainer nut. Place the plunger assembly in the drain. Install the horizontal rod so that the end goes through the loop in the bottom of the height adjuster. Install and hand tighten the pivot ball nut. Attach the swivel connector to the end of the horizontal rod. Attach the swivel connector to the end of the pull rod. Position as desired and tighten with a small, flat bladed screwdriver. plunger height adjuster flange sealing gasket mack gasket friction ring pull rod retainer nut tee pivot ball nut horizontal rod tailpiece swivel connector Cleaning (34133 only) If the flow of water diminishes over time, unscrew the aerator using the service key. Rinse the aerator with clear water. Reinstall the aerator. Tighten it with the service key. Replacement Parts 4 16 15 1 13 2 30x1.5 14 6 3 12 11 5 9 1 aerator 98926000 2 handle 34095XX0 3 color-ring set 98927000 4 spout 98928XX0 5 nut 98929XX0 6 pull rod 96657XX0 7 cold cartridge 94008000 8 hot cartridge 94009000 9 fixation set 13961000 10 connection hose 94071001 11 handle fixing set 98932000 12 flange 98930XX0 13 aerator 97360XX0 14 ball joint 97362XX0 15 spout 98931XX0 16 aerator service key 98987000 17 compression fittings (pr.)......... 88513000 XX = color 00 = chrome 82 = brushed nickel 7 8 17 10 Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets, and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cleaning. Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime, however please pay attention to the following points when cleaning faucets and showers: Only use cleaning materials which are explicitly intended for this type of application. Never use cleaning materials which contain hydrochloric, formic, phosphoric, or acetic acid, as they cause considerable damage. Never mix one cleaning material with another. Never use cleaning materials or appliances with an abrasive effect, such as unsuitable cleaning powders, sponge pads, or micro fiber cloths. Cleaning Instructions for Faucets and Showers Please follow the cleaning material manufacturer’s instructions. In addition, pay attention to the following points: Clean the faucets and showers as and when required Use the amoun...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias