Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação American Standard, Modelo 2645V.068C

Fabricante : American Standard
Arquivo Tamanho: 728.4 kb
Arquivo Nome : f61bc36d-ad91-4f6f-9160-f1622caf6432.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Do not use this air bath. Disconnect the air bath and have the problem corrected by a licensed electrician before using. SAVE THESE INSTRUCTIONS 3 754072-100 ft I 1 General Installation Information Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling! Do not make unauthorized modifications to the air bath system. This could adversely affect the safety and performance of the air bath and void the warranty. Do not handle or move the air bath by the air blower or piping system. Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. For electrical requirements, refer to section titled “Air Bath Electrical Installation Instructions”. Check for availability of optional American Standard wall tiling bead (required for recess installation). Protect all finished surfaces of the air bath during construction and installation using a drop cloth. WARNING: Do not lift air bath by the piping harness at any time. List of Required Tools and Supplies: Tools Supplies • Level • Nails • Tape Measure • Putty • Pipe Wrench • Caulking (waterproof) • Slip Joint Pliers • 1 x 4 Stringers • Screw Driver • Drop Cloth • Standard Woodworking Tools • Cement, Plaster, Grout • Personal Safety Equipment • Caulking Gun LIST OF OPTIONAL COMPONENTS (NOT INCLUDED): Optional Components (Not Included) Required Components (Not Included) Description Model Number Apron Kit Tile Bead Kit Drain (Specify Finish) Evolution™ 5' x 32" 2422V.068C 9261.019 751755-100 1599.205.XXX* Evolution™ 5' x 36" 2771V.068C 9261.019 751755-100 1599.205.XXX* Evolution™ 6' x 36" 7236V.068C 9271.019 751755-100 1599.205.XXX* Evolution™ 5' x 32" IA 2425V.168C - RHO 2425V.268C - LHO INTEGRAL NOT APPLICABLE 1599.205.XXX* Evolution™ Oval 2645V.068C 9266.018 751755-100 1583.470.XXX * These models require American Standard Deep Soak Max Drain 1599.205 754072-100 4 SPECIFICATIONS: SIDE VIEW DRAIN / OVERFLOW GENERAL SPECIFICATIONS FOR EVOLUTION AIR BATHS Description Dimensions L-W-H Drain / Overflow Height to Underside of Deck: C Cut Out Pier G x F Rough-In Recess E x D Tub Edge to Centerline Overflow: J Weight with Water / Floor Loading Product Weight Apron / Mounting Gallon to Overflow 2422V.068C 5' x 32" L 1524mm (60") W 813mm (32") H 546mm (21-1/2") A 20-1/8" (511 mm) B 11" (279 mm) C 20" (508 mm) 58-1/2" (1485 mm) x 30-1/2" (774 mm) 60-3/16" (1528 mm) x 30-1/2" (774 mm) 83mm (3-1/4) 690lb (313kg)/ (260kg/sq.m) 53lb/sq.ft. 74 lb. (34 kg.) Optional 74 gal. (280 l.) 2771V.068C 5' x 36" L 1524mm (60") W 914mm (36") H 546mm (21-1/2") A 20-1/8" (511 mm) B 11" (279 mm) C 20" (508 mm) 58-1/2" (1485 mm) x 34-1/2" (876 mm) 60-3/16" (1528 mm) x 34-1/2" (876 mm) 83mm (3-1/4) 800lb (363kg)/ (260kg/sq.m) 53lb/sq.ft. 75 lb. (34 kg.) Optional 87 gal. (329 l.) 7236V.068C 6' x 36" L 1829mm (72") W 914mm (36") H 546mm (21-1/2") A 20-1/8" (511 mm) B 11" (279 mm) C 20" (508 mm) 70-1/2" (1790 mm) x 34-1/2" (876 mm) 72-3/16" (1833 mm) x 34-1/2" (876 mm) 83mm (3-1/4) 1031lb (467kg)/ (280kg/sq.m) 57lb/sq.ft. 106 lb. (48 kg.) Optional 111 gal. (420 l.) 2425V.168C IA-RHO 2425V.268C IA-LHO 5' x 32" L 1524mm (60") W 813mm (32") H 521mm (20-1/2") A 19-1/8" (485 mm) B 10-1/2" (266 mm) C 20-1/4" (515 mm) N/D 60-3/16" (1528 mm) x 30-1/2" (774 mm) 73mm (2-7/8) 675lb (306kg)/ (262kg/sq.m) 54lb/sq.ft. 92 lb. (42 kg.) Included 70 gal. (265 l.) 2645V.068C Oval L 1676mm (66") W 914mm (36") H 502mm (19-3/4") A 15-1/4" (387 mm) B 8-1/4" (209 mm) C 18-1/4" (464 mm) 64" (1625 mm) x 34" (863 mm) 66-3/16" (1681 mm) x 34-1/2" (876 mm) 44mm (1-3/4) 580lb (263kg)/ (175kg/sq.m) 36lb/pies cuadrados 96 lb. (44 kg.) Optional 58 gal. (219 l.) TABLE 1 5 754072-100 ROUGHING-IN REFERENCES 5' x 32" (MODEL 2422V.068C) 6' x 36" (MODEL 7236V.068C) OVAL (MODEL 2645V.068C) 5' x 32" IA-RHO (MODEL 2425V.168C-RHO) 5' x 32" IA-LHO (MODEL 2425V.268C-LHO) - shown DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7. 754072-100 6 INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this air bath may require framing procedures other than those shown. Locate studs as needed. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the air blower and controls. It is strongly recommended that an additional opening be provided for access to the drain components. The apron should not be used as the primary access opening. 1. Position the air bath into t...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias