Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação American Standard, Modelo 2422L / V

Fabricante : American Standard
Arquivo Tamanho: 1.75 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Always follow local and national electrical codes 50' Wire Length 100' 115V Power Line 150' 200' 12 Wire Size (AWG) 10 8 8 753737-100 Rev. E 12 For 6060L/V Corner Only OPERATION WARNING: Prior to operation, review the Important Safety Instructions Fig. 1 listed at the beginning of this instruction manual. Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the temperature of the water in the bath. Pressure Switch The heater is equipped with a preset pressure switch. The pump must be running with water flowing in the whirlpool to allow the heater to turn on. At initial start-up with power ON, push the GFCI test button. The reset button should pop out. Push this button in to reset. If the GFCI fails to operate in this manner, there is a ground fault or malfunction, indicating the possibility of electrical shock. Turn off the power and do not 1. Route two separate branch circuits to the junction box near the whirlpool as shown in Figure 2. Each branch circuit MUST BE GFCI2. Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the 8 AWG solid copper conductor supplied with the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3. The conductor is secured to the lugs using set screws. The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the homes electricalFig. 2 Fig. 3 The heater includes an exclusive "Intelligent High-Limit". This safety circuit will not "false trip" from hot tap water. It will only turn the heater To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. (2) Drain water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. (4) The heater circuit will ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS BLACK WHITE 120 VAC GND. SEPARATE 20 AMP GFCI OUTLET (for 2.1 H.P.R. PUMP ONLY) SEPARATE 15 AMP GFCI OUTLET PUMP/MOTOR ELECTRICAL INSTALLATION HEATER BLACK WHITE 120 VAC GND. SEPARATE 15 AMP GFCI OUTLET RUN 8 AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP/MOTOR FRAME LUG AND FROM PUMP/MOTOR LUG TO APPROVED GROUND AS SHOWN (PUMP/MOTOR) TO GROUND SECOND COPPER CONDUCTOR FIRST COPPER CONDUCTOR PUMP/MOTOR FRAME WITH BONDING LUGS HEATER ON E-ZINSTALL™ WHIRLPOOLHEATER (HEATER) HEATER ON LIGHT Bonding Lug on Heater Housing E-Z INSTALLHEATER ™WHIRLPOOLFACTORY INSTALLED NOT FOR RESALE HEATER P/N: 753174-100 Indicator Light This light turns on whenever the heater is operating. High-Limit Switch off if the thermostat fails. If the high-limit trips frequently, call a service technician. automatically reset in less than 15 minutes. (5) Restore power to the heater. (6) Whirlpool bath is now ready to use. ELECTRICAL CONNECTIONS Install a separate 120VAC / 15AMP dedicated circuit with GFCI (Ground Fault Circuit Interrupter) protection. use the bath until the source of the problem has been identified and corrected. PROTECTED and must use copper conductors only. panel or approved local bonding point as shown in Figure 3. 13 753737-100 Rev. E OPERATION: NOTE: Each whirlpool is shipped from the factory with an air actuator on/off switch and pump with attached power supply cord. OPERATING THE SYSTEM WITHOUT WATER (DRY RUNNING) WILL CAUSE PUMP DAMAGE AND VOID THE WARRANTY. Always fill the whirlpool before operating the pump. The air switch is mounted either on the deck or side wall of the tub. 1. Fill the Whirlpool: Water level must be at least one inch (25mm) above the highest jet for proper operation. (See diagram below.) Do not fill whirlpool more than 2/3 full prior to the user completely immersing themselves into unit. 2. Start Whirlpool: Push on center of button. Button will depress and whirlpool will start. 3. Stop Whirlpool: Depress and release button and whirlpool will stop. SAFE-T-HEATER OUTLET MUST BE GFCI PROTECTED (all heaters require separate GFCI) AIR ACTUATOR SWITCH (location varies with model) AIR TUBING WATER LEVEL REMOVABLE BLANK * * 6060L/V includes factory installed heater 4. Air Volume Control Adjustments: Water turbulence is determined by the amount of air mixed with the water. Rotate the air volume control counterclockwise for more turbulence--clockwise for less. Air Volume Control Adjustments: MORE AIR LESS AIR 753737-100 Rev. E 14 Adjustable Flow Clean Jet™: The water flow action may be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and clockwise for soft. tating the nozzle counterclockwise for vigorous and clockwise for soft. NOTE: You may balance the air volume control and nozzle adjustment for the most desirable condition. Large Jet Small Jet Softer Massage Softer Massage (counter-clockwise) (counter-clockwise) More Vigorous Massage More Vigorous Massage (clockwise) (clockwise) Lifetime™ Drain Model 1599 (required on Models 7236L/V,...

Este manual também é adequado para os modelos :
Outros acessórios para a casa - 2645L / V (1.75 mb)
Outros acessórios para a casa - 2425L / V (1.75 mb)
Outros acessórios para a casa - 2732L (1.75 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias