Log:
Assessments - 4, GPA: 3.5 ( )

Instruções de Operação Desa Tech, Modelo PC4670LP

Fabricante : Desa Tech
Arquivo Tamanho: 281.52 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening pro- pane/LP supply tank slowly. Note: If not opened slowly, excess-flow check valve on propane/LP tank will stop gas flow. If this happens, close propane/ LP supply valve and open again slowly. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect unit and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. The appliance must be isolated from the gas supply piping system by closing its individual equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa). Equipment Open Shutoff Valve Closed Figure 6 - Equipment Shutoff Valve For more information, visit 6 OWNER’S MANUAL INSTALLATION (Continued) 2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 3. Check all joints from propane/LP supply tank to equipment shutoff valve (see Figure 7). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once. Pressure Testing Appliance Gas Connections (Fixed Piping System Only) 1. Open equipment shutoff valve (see Figure 6, page 6). 2. Open propane/LP supply tank valve. 3. Check all joints from equipment shutoff valve to supply hose. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once. Propane/LP Supply Tank (100 lb. or larger) Equipment Shutoff Valve Control Valve Location Figure 7 - Checking Gas Joints SETUP Your Comfort Glow Patio Fire is designed to operate with lava rock piled in and around the burner, and refractory logs placed on top of the lava rock. Carefully pour supplied lava rock into basin to cover the burner. Be sure that the burner and burner ports are covered completely by lava rock to better disperse the flame and to create a more natural looking fire. CAUTION: Place lava rock carefully. Be careful not to damage the burner, ignitor electrode, or thermocouple when adding the lava rock. Place the six refractory logs on top of the lava rock. The arrangement is left to your personal preference. Try different placements to achieve your desired flame pattern. Note:Sooting on the logs is natural. You may clean with a soft bristle brush. WARNING: Solid fuels shall not be burned in this gas fireplace. BATTERY INSTALLATION Your Comfort Glow Patio Fire uses an electronic ignitor which requires one AA alkaline battery (not included). The battery compartment is located in the ignitor module behind the ignitor button. To install the battery into the ignitor: 1. Locate the ignitor button on the control panel (see Figure 8). 2. Rotate the ignitor button counterclockwise to remove. 3. Install a fresh AA alkaline battery into the ignitor module, positive terminal first. 4. Replace button by rotating clockwise. Tighten finger tight. Do not overtighten. Note:Your fire pit may be lighted using a match (see Lighting Instructions, page 8). Ignitor Button Figure 8 - Control Panel OPERATING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. WARNING: Do not use this appliance if any gas control parts have been under water. Immediately call a qualified service person to inspect the Patio Fire and replace any part of the control system and any gas control that has been under water. WARNING: All gas burning appliances may produce smoke, soot, or carbon monoxide during operation. These fumes can be harmful if the appliance is used anywhere other than in an open air, fully-vented area. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the ground because some gas is heavier than air and will settle on the ground. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. Continued 7 For more information, visit PROPANE/LP GAS DECORATIVE PATIO FIRE OPERATING APPLIANCE Continued LIGHTING INSTRUCTIONS Lighting Using the Electronic Spark Ignition System 1. Open equipment shutoff valve. 2. If you smell gas, STOP! Turn the equipment shutoff valve to OFF. Check gas connections for leaks. Do not continue until gas leaks are corrected. 3. After correcting leaks, wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the safety information in column 3, page 7. If you do ...

Este manual também é adequado para os modelos :
Outros acessórios para a casa - PC3460LP (281.52 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias