Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Cal Spas, Modelo 6200

Fabricante : Cal Spas
Arquivo Tamanho: 5.05 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The panel will display “TEMP LOCK” when the set temperature is locked. To unlock the set temperature: Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, and then the “DOWN” button. Circulation Pump This is an optional feature. The circulation pump will come on when the system is checking temperature, during filter cycles, during freeze conditions, or when another pump is on. Preset Filter Cycles There are two filter cycles per day. The start and end times of each cycle are programmable. To program, set the time as instructed above, then press “MODE/PROG” to advance to the next setting (or to exit after the last setting). The default filter cycles are as follows: The first filter cycle is automatically activated at 8:00 AM and operates the pump until 10:00 AM. The “FILTER 1” indicator icon will light when filter 1 is running. The second filter cycle is automatically activated at 8:00 PM and operates the pump until 10:00 PM. The “FILTER 2” indicator icon will light when filter 2 is running. The pump and the ozone generator will run during filtration. At the start of each filter cycle, the blower will run on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run for five minutes. In the event of power loss or shut down, the time of day will need to be reset for filter cycles to run according to your desired programming. Clean up Cycle When the pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is turned off or times out. The pump and the ozone generator will run for one hour. Ozone This is an optional feature. On most systems, the ozone generator (if installed) runs during filter cycles (except when pump 1 is operating at high speed on a non-circ ulating system) and during clean-up cycles. On some systems, the ozone generator operates whenever the pump runs. If your system is configured with the optional ozone disable feature, the ozone generator will turn off for one hour any time a function button (“JETS 1”, “JETS 2”, “OPTION” etc.) is pressed. Freeze Protection If the temperature sensors detect a drop to 44°F within the heater, the pump automatically activates to provide freeze protection. The equipment stays on until four minutes after the sensors detect that the spa temperature has risen to 45°F or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a four-minute delay in turnoff. Periodic Reminder Messages Press the “Mode” button to reset a displayed reminder. Message Frequency Action Required rPH Every 7 days Test and adjust chemical levels per manufacturer’s instructions. rSA Every 7 days Test and adjust chemical levels per manufacturer’s instructions. rCL Every 30 days Remove, clean, and reinstall filter per manufacturer’s instructions. rtg Every 30 days Test and reset GFCI per manufacturer’s instructions. Drain and refill spa per manufacturer’s instructions. rdr Every 90 days Drain and refill spa per manufacturer’s instructions. rCO Every 180 days Clean and condition spa cover. rCH Every 365 days Install New Bio-Clean™ Filter. Diagnostic Messages Message Meaning Action Required No message on display. Power has been cut off to the spa. The control panel will be disabled until power returns. Spa settings and time of day will be preserved for 30 days with a battery back-up. OHH “Overheat” - The spa has shut down. One of the sensors has detected 118°F at the heater. DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. Once the heater has cooled, reset by pushing any button. If spa does not reset, shut off the power to the spa and call your dealer or service organization. OHS “Overheat” - The spa has shut down. One of the sensors has detected that the spa water is 110°F. DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. At 107°F, the spa should automatically reset. If spa does not reset, shut off the power to the spa and call your dealer or service organization. ICE “Ice” - Potential freeze condition detected. No action required. The pumps and the blower will automatically activate regardless of spa status. Sna Spa is shut down. The sensor that is plugged into the Sensor “A” jack is not working. If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools.) Snb Spa is shut down. The sensor that is plugged into the Sensor “B” jack is not working. If the problem persists, contact your dealer or service organization. (May appear temporarily in an overheat situation and disappear when the heater cools.) Sns Sensors are out of balance. If this is alternating with the temperature, it may just be a temporary condition. If the display shows only ...

Este manual também é adequado para os modelos :
Outros acessórios para a casa - 5100 (5.05 mb)
Outros acessórios para a casa - 6300 (5.05 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias