Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Dometic, Modelo 3400

Fabricante : Dometic
Arquivo Tamanho: 448.52 kb
Arquivo Nome : 884d38f0-8eae-47df-af4a-d33d5e242d3b.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Install the flange gasket over the T-bolts (fig. 10). STEP 12: Install floor flange adapter with words “THIS SIDE UP” facing up. Tighten adapter to floor flange using four flat washers and hex nuts. Tighten in criss-cross pattern (fig. 11). STEP 13: Temporarily set the toilet in place on the floor flange (fig. 14). STEP 14: Mark the holes for the two toilet mounting bolts (fig. 15). STEP 15: Pick up toilet and set aside. Drill 3/16-inch pilot holes in the floor (fig. 16). IMPORTANT: If replacing an existing toilet that uses a 2-bolt floor flange, drill two 5/16-inch dia. holes in old floor flange that align with two additional holes in floor flange adapter. Use two #10 or 12 x 1-1/2-inch wood screws and washers for these drilled holes, and two T-bolts with flat washers and nuts to fasten flange gasket and floor flange adapter to old floor flange. Do not use old hardware or seal. FOR MODEL 3400 TOILET WITH REMOTE SWITCH OPERATION, see page 7 for wall switch installation instructions. Fig. 9 Fig. 14 Fig. 10 Fig. 15 Fig. 11 Fig. 16 STEP 16: With toilet close to floor flange, connect flexible water supply hose to the water line fitting (fig. 17). STEP 17: Insert the positive (+) 12 VDC wire into position 1 of the green terminal block and tighten the screw securely. Insert the negative (-) 12 VDC wire into position 2 of the green terminal block and tighten the screw securely (fig. 18). STEP 18: REMOVE RED CAP FROM MIDDLE OF FLANGE ADAPTER BEFORE FINAL TOILET INSTALLATION. IMPORTANT – DO NOT ATTEMPT TO SLIDE THE TOILET OVER THE FLANGE ADAPTER. THE TOILET MUST BE SET DOWN OVER THE ADAPTER TO PREVENT POSSIBLE DAMAGE. STEP 19: Set the toilet in place (fig. 19) and secure to floor with the #14x2-1/2 inch long lag bolts (fig. 20). Install decorative bolt caps by pushing them onto bolt heads (fig. 21). STEP 20: Place the rear access cover on the back of the toilet. Press down firmly to seat the fastening strips. STEP 21: Turn on electrical power and water to toilet. Lift flush handle and fill toilet bowl with water. Wait one hour, then inspect the floor around and under the rear of the toilet for leaks or dampness. If no leaks are present, toilet is ready for operation. Fig. 17 Fig. 20 Fig. 19 Fig. 18 Fig. 21 MODEL 3400 REMOTE FLUSH SWITCH INSTALLATION 3400 series toilets feature a remote flush switch to control the “Flush” and “Add Water” functions. Follow the instructions below for switch installation. STEP 1: Select a location for the switch. 8 feet of cable (2.4 m) is provided. You may need to supply more wire, depending on how far you locate the switch from the toilet. STEP 2: Cut an opening 1-1/4” wide x 1-5/8” high (see diagram at right). STEP 3: If installing the switch in a shallow wall, you may need to use the spacer between the wall and the switch assembly cover to allow space for the wire connectors. If so, route the cable through the spacer before proceeding to the next step. STEP 4: Route the 3-conductor cable through wall cut-out and on to toilet. Cable can be routed with water supply line and power wires (see page 5, Step 9). Leave a minimum of 30 inches (.76m) of cable to allow easy wiring at toilet. STEP 5: Fasten the switch assembly to the wall with the #6x1” screws (included), making sure to install with the label “THIS SIDE UP” on top. Otherwise, the “Flush” and “Add Water” functions will be reversed. STEP 6: Snap cover onto switch assembly to complete switch installation on wall. STEP 7: WITH THE ELECTRICAL POWER OFF, connect the red, black and white wires from the switch to the red, black and white wires connected to the 11, 12 and 13 terminals on the control module. See page 6, Step 17 for other wiring procedure. Spacer outline Cover outline 1-5/8 inch (41 mm) 1-1/4 inch (32 mm) REMOTE FLUSH SWITCH COMPONENTS IMPORTANT INFORMATION BEFORE OPERATION 1. Fill freshwater tank and add deodorant to holding tank through toilet bowl. 2. Make sure all guests understand the operation of the toilet system. 3300 models: This flushing instruction label is located under the seat, and is easily read when the seat is raised. 3400 models: "Add Water" and "Flush" are clearly marked on the remote switch. 3. Shut off the toilet system before servicing and do not leave the vehicle with toilet system circuit breaker on. 4. Never use drain openers, alcohol, solvents, etc. in the toilet. 5. If the toilet does not function properly, refer to the Troubleshooting section of this manual and repair as necessary. If problem persists, contact your local SeaLand product dealer or see the Customer Service section of this manual. ELECTRONIC FLUSH AND FORGET® OPERATION DO NOT FLUSH FOREIGN OBJECTS THROUGH TOILET FLUSH HANDLE TOILET REMOTE FLUSH SWITCH TOILET 1. To add water to the toilet before using (if necessary), raise flush handle until desired water level is reached. (Water flow will stop automatically after a pre-programmed period of time). 2. To flush toilet, press flush handle down. Water will flow into bowl for two second...

Este manual também é adequado para os modelos :
Outros acessórios para a casa - 3300 (448.52 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias