Installation If fitted in a room containing a bath or shower, to comply with the current I.E.E. Regulations, a cable outlet will be necessary with the supply to the heater controlled by a double-pole pull-cord switch having a contact separation of 3mm in each pole. The body of the switch should be situated as to be normally inaccessible to a person using a bath or shower. Should Equipotential Earth Bonding be required the earthing conductor in the supply cord is deemed to provide the supplementary bonding connection (see Regulation 547-03-0, ’16th’ Edition I.E.E. Wiring Regulations. IMPORTANT - Protect the electrical connection whilst handling the towel rail. The towel rail must be permanently fixed to the wall using the wall brackets supplied. The rail must be mounted vertically as shown observing the minimum clearances stated. WARNING - The towel rail is heavy. Care must be taken when lifting and fitting the towel rail. Wall mounting The wall mounting accessory pack contains: (a) 4 mounting brackets (b) 1 allen key (c) 4 wall mounting screws, washers and wall plugs (d) 4 hex. stud screws IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Dimensions (millimetres) Installation and Operating Instructions DTR Towel Rails Models : DTR175W, DTR175C, DTR350W & DTR350C Fig. 1 08/50116/1 (UK) Issue 1 DTR 350 602 100 min. 843 shelf Procedure for wall mounting Step 1 A B A B DTR 175 250 390 DTR 350 380 625 Fig. 2 Mark suitable hole positions for the four fixing brackets (ensuring they are horizontal) - see Fig. 2, and allow enough room above and below for the clearance stated. Drill and plug the wall to suit - see Fig. 3. W Fig. 3 Step 2 The hex. stud screw in the slot has to be removed using the allen key provided first, to separate the inner ‘Z’ and outer ‘W’ sleeves of the wall brackets - see Fig. 4. Z Mount the four outer sleeve wall brackets in line with the drilled outW holes using the screws provided - see steps 1 - 4 in Fig. 3. Note: the brackets have slot holes to allow for possible adjustment later. Step 3 X Remove the cap ‘Y’ from the inner sleeve assembly, unscrew the nut and remove the rail support ‘X’ - see Fig. 5. On the inner side (wall) of the towel rail position the inner sleeve between the cross rails as indicated in Fig. 1. Position the rail support to receive the bolt on the inner sleeve and hand tighten with the nut - see Fig. 3. Slide into position (see suggested positions in Fig. 1). Y W Step 4 Lift the towel rail now with the inner sleeve assembly in position, and align with the outer sleeve previously fixed to the wall. When all four inner sleeves are inserted correctly into the outer sleeves of the brackets tighten each nut fully. Replace the cap ‘Y’ and the hex. stud screw. The distance the towel rail can be positioned from the wall can be varied by adjusting the hex. stud screws. When in the desired location, tighten fully to secure the towel rail to the wall. To assist with the alignment...

Este manual também é adequado para os modelos :
Outros acessórios para a casa - DTR175C (170.43 kb)
Outros acessórios para a casa - DTR350C (170.43 kb)
Outros acessórios para a casa - DTR350W (170.43 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias