Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Enviro, Modelo ACCENT 25BV

Fabricante : Enviro
Arquivo Tamanho: 480.14 kb
Arquivo Nome : accent25manual.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


DO NOT cut or remove the grounding prong from this plug. REMOVING / INSTALLING THE BLOWER 1. Turn the unit off, open the door and remove the log set. Remove brick panel(s) (see Removing and Installing Brick Panels). Remove the burner tray assembly by removing the two (2) screws on either side of the tray. Pull tray up at the back and lift out. 2. Disconnect the gas line to the nipple. Remove the three (3) screws holding the burner control tray to the back firewall. Lift tray up on left side and pull out. 3. Pull blower towards you. Disconnect wires from the blower and remove. 4. To re-install perform the preceding steps in reverse. INSTALLING REMOTE THERMOSTAT OR WALL SWITCH RECOMMENDED WIRE SIZE for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire) 1. Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch. 2. Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. Use the terminals marked (TP/TH and TH). RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE) WHEN USING WALL THERMOSTAT WIRE SIZE MAXIMUM LENGTH 14 GAUGE 100 FEET 16 GAUGE 64 FEET 18 GAUGE 40 FEET 20 GAUGE 18 FEET Text Box: CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing 6. GAS LINE CONNECTIONS and TESTING WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a 3/8 x 3 inch black iron nipple located on the right side of the unit terminating in a 3/8" male NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1. • The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system. The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1/2 PSIG (3.45 kpa) or damage will occur to the valve. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Always check for gas leaks with a soap and water solution after completing the required pressure test. TO TEST VALVE PRESSURES The pressure taps are located on the left side of the valve • Turn set screw 1 turn counter clockwise to loosen,. • Place 5/16" (8 mm) I.D. hose over pressure tap system. • Check pressures using a manometer. • When finished, release pressure, remove hose & tighten set screw. ORIFICE SIZES, PRESSURES AND BTU'S All models are equipped with a variable output gas control. NATURAL PROPANE MAIN BURNER ORIFICE: #42 DMS #53 DMS Manifold Press: 3.8"wc / 0.95 kpa 11.0"wc / 2.74 kpa Min. Manifold Press: 1.1"wc / 0.27 kpa 2.7"wc / 0.67 kpa Max. Supply Press: 7.0"wc / 1.74 kpa 12.0"wc/ 2.98 kpa Min. Supply Press: 5.0"wc / 1.25 kpa 11.5"wc / 2.86 kpa Max. BTUH Input: 25,000 btu/h/ 7.32 Kw 25,000 btu/h/ 7.32 Kw Min. BTUH Input: 12,500 btu/h/ 3.66 Kw 12,500 btu/h/ 3.66 Kw Output Fan on 18,875 btu/h/ 5.53kw Fan on, 19,250 btu/h/ 5.64kw Fan off 18,000 btu/h/ 5.27 kw Fan off 18375 btu/h/ 5.38kw Text Box: Inlet Pressure Tap Text Box: Manifold Pressure Tap Text Box: 3/8” Pipe Text Box: Pilot Adjustment Screw Text Box: Gas Control Knob Text Box: Hi Low Knob NEVER USE AN OPEN FLAME FOR LEAK TESTING 7. INSTALLATION OF LOGS, EMBERS and BRICK PANELS INSTALLING THE GLOWING EMBERS and LOGSET A bag of ceramic fiber embers is provided for use on the burner PAN. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. Use only a single layer. Do not pile embers. The use of other foreign materials on the burners may create dangerous conditions. If over time, through cleaning and servicing, these embers require replacement, contact your nearest ENVIROGAS dealer for replacement embers. 1. Carefully remove log from unit. Check to ensure there is no damage. It is very important to install this log in its proper position to insure safe, optimum operating conditions. 2. Place the log set into the firebox with the burnt area forward. Locate the log by seating it down onto the burner tray supports already installed. 3. Gently remove the ember material from the plastic bag. Place a single line of embers on burner as shown beside. 4. Carefully avoid any clumping or large build ups. Do not pack down, leave embers loose 5. Upon the first light up, watch for ignition to all burner ports. If a long delay is noted: First, wait for t...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias