918-240g FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 10/07/08 Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPTON DEALER in your area. Keep those HAMPTON FIRES burning. SAFETY NOTE: If this Insert is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building, fi re officials, or authority having jurisdiction about restrictions and installation inspection requirements in your area. The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit. Hampton HI300 Wood Cast Insert TABLE OF CONTENTS SAFETY LABEL Safety Label For HI300..................................................4 UNIT DIMENSIONS Standard Faceplate .......................................................5 Cast faceplate................................................................5 UNIT DIMENSIONS Oversize Faceplate........................................................6 Cast Faceplate ..............................................................6 INSTALLATION Before InstallingYour Insert ...........................................7 Chimney Specifi cations .................................................7 Wood Insert Specifi cations ............................................7 Flue Connector Bracket .................................................9 Masonry And Factory Built Fireplace Clearances .........8 Alternate Floor Protection Materials ..............................8 Installing Your Insert ......................................................9 Optional Flue Connector Kit ..........................................9 Installation Into a Masonry Fireplace ...........................10 Installation Into a Factory Built Fireplace.....................10 Standard Cast FaceplateInstallation............................ 11 Oversize Cast Faceplate Installation ...........................14 Fan Installation ............................................................18 Power Outlet Conversion.............................................19 Firebrick Assembly ......................................................21 Flue Baffle & Secondary Air TubeInstallation ..............21 Draft Control ................................................................21 OPERATING INSTRUCTIONS Safety .........................................................................22 Guidelines....................................................................22 First Fire ......................................................................22 Wood Storage ..............................................................23 Creosote ......................................................................23 Ash Disposal................................................................23 Fan Operation .............................................................23 MAINTENANCE Door Gasket ................................................................24 Glass Cleaning ............................................................24 Door Removal..............................................................24 GlassReplacement ......................................................24 HandleReplacement ....................................................24 Latch Adjustment .........................................................25 PARTS LIST Main Assembly ............................................................26 Standard Cast Faceplate .............................................27 Oversize Cast Faceplate .............................................28 Brick Panels.................................................................29 WARRANTY Warranty ......................................................................31 Hampton HI300 Wood Cast Insert SAFETY LABEL SAFETY LABEL FOR HI300 This is a copy of the label that accompanies your Hampton Insert. We have printed a copy of the contents here for your review. NOTE: Hampton units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. LISTED FACTORY BUILT FIREPL ACE INSERTCERTIFIED FOR USE IN CANADA AND U.S.A. MODEL: HI300TESTED TO: ULC S628- 93 / UL 1482 REPORT NO. 219-S-03-2DO NOT REMOVE THIS LABEL264 COMPONENTS REQUIRED FOR INSTALLA TION: 6IN / 150MM STAINLESS STEEL LINER. DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONTOF APPLIANCE. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USEWITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATEFIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY....