|
Instruções de Operação Cooper Lighting, Modelo GPF15SPW764
Fabricante : Cooper Lighting Arquivo Tamanho: 107.76 kb Arquivo Nome : b7a117ec-d2e6-4c11-a970-330688df85aa.pdf
Língua de Ensino:
|
|
|
|
Ir para baixar
Facilidade de uso
1000W MH 10 1/2" [267]. ORDERING INFORMATION SAMPLE NUMBER: GPF15SPW764 PRODUCT LAMP WATTAGE LAMP TYPE 1 BALLAST TYPE 1 VOLTAGE 1 DISTRIBUTION OPTIONS + FAMILY 15=150W S=High Pressure H=Reac./HPF 2=120V 76=7x6 ACCESSORIES GPF=General 20=200W Sodium N=Hi. Reac./NPF 0=208V 77=7x7 3 (See Below) Purpose 25=250W V=Mercury P=Hi. Reac./HPF 4=240V 12=1x2 4 Flood 40=400W M=Metal Halide R=Reac./NPF 7=277V 23=2x3 4 75=750W R=Super Metal Halide W=CWA 8=480V 24=2x4 5 91=1000W C=CWI 9=347V 43=4x3 4 24=250/400 M=Mag. Reg. W=Multi-Tap wired 120V 44=4x4 5 wired 250W K=10KV CWA N=Multi-Tap wired 277V 55=5x5 5 42=400/250 5T=5-Tap wired 277V 2 62=6x2 4 wired 400W 65=6x5 4 OPTIONS + ACCESSORIES [Must be listed in the order shown and separated by a dash] OPTIONS (add as suffix) ACCESSORIES (order separately) 1=Single Fuse, Internally Mounted (120 or 277V) OA1179=Top/Bottom Visor 2=Double Fuse, Internally Mounted (208, 240, or 480V) OA1180=Side Visor 4=Photocontrol Receptacle OA1181=Wire Guard BK=Black OA1182=Vandal Shield AP=Grey OA1208=TufGuard Vandal Shield A=Captive Door Screws VS/NK=Vandal Shield (For Wattages Below 1000W) C=Slipfitter 2 3/8" to 3" O.D.—cord thru housing VS/NK/1000=Vandal Shield (For 1000W Units) H=Plug-in Starter Receptacle 6 M=MOV Lightning Surge Protectors 7 R=Removable Power Tray 8 S=Slipfitter 2 3/8" to 3" O.D. with leads thru fitter T=Trunnion Mount U=UL/CSA Listed W=Wall Mount OPTIONAL COLORS [Standard color is bronze, other finish colors available. Consult your Cooper Lighting representative] BK AP Black Grey NOTE: 1 Refer to technical section for lamp/ballast/voltage compatibility. 2 250/400W, 400/250W MH, HPS, and 400W MH only. 3 1000W only. 4 Available in MH only. 1000W requires reduced envelope lamp. 5 Available in HPS only. 6 Not available in 1000W. 7 MOV option is not available for any system requiring a three position terminal block (Example—120/240V incoming line). In order for MOV option to function center terminal of three position terminal block must be connected to “Earth” ground. 8 400W or below, except for 400W Mag. Reg. LATCHES Formed aluminum flush draw-action latches offer easy access to lamp compartment without tools. HOUSING Aerodynamically designed, architecturally styled die-cast aluminum housing. Standard dark bronze polyester powder finish. Other finish colors available. Consult your Streetworks Representative. ANSI wattage/source label. Optional NEMA twistlock photocontrol receptacle. DOOR Spring-loaded die-cast aluminum door with integral cast hinges for removal without tools. Door gasket is closed-cell silicone, providing maximum protection of interior components from the elements. LENS Heat- and impact-resistant tempered glass lens. REFLECTOR Computer designed precision formed reflector system delivers superior beam control and efficiency. BALLAST Ballast components are hard mounted to fixture housing for maximum heat dissipation and extended component and lamp life. Plastic terminal block. Prewired with 3' 14/3 STWA cord. MOUNTING Heavy-duty steel yoke provides flexibility in mounting to a variety of surfaces. Slipfitter for 2 3/8" to 3" O.D. tenon and trunnion mount also available. EPA: Effective Projective Area: 2.7 SHIPPING DATA Approximate Net Weight: 59 lbs. (27 kgs.) 142 STREETWORKS Outdoor Lighting Solutions Cooper Lighting GPF GENERAL PURPOSE FLOOD FLOODLIGHTING PHOTOMETRICS [Complete IES files available at GPF40S76.IES 400-Watt HPS 50,000 Lumen Lamp Tilt-45° A B C D E 3210 GPF91S77.IES 1000-Watt HPS 140,000 Lumen Lamp Tilt-45° 6 5 4 3 2 1 0 1 5 4 3 2 1 0 1 2 3 4 5 A B C D E GPF40M76.IES 400-Watt MH 36,000 Lumen Lamp Tilt-45° 23 5 4 3 2 1 0 1 2 3 4 5 A B C ED 3 2 1 0 1 1 2 33 2 1 GPF91M77.IES 1000-Watt MH 110,000 Lumen Lamp Tilt-45° DRILLING PATTERN FOR YOKE- AND TRUNNION-MOUNT 6 FOOTCANDLE TABLE Select mounting height and read across for footcandle values of 5 each isofootcandle line. Distance in units of mounting height. 4 Mounting Footcandle Values for Height Isofootcandle Lines 3 ABCDE GPF40S76.IES / GPF40M76.IES 2 20' 10.00 5.00 2.00 1.00 0.50 25' 6.40 3.20 1.28 0.64 0.32 1 30' 4.44 2.22 0.89 0.44 0.22 0 35' 3.27 1.63 0.65 0.33 0.18 40' 2.50 1.25 0.50 0.25 0.13 1 GPF91S77.IES / GPF91M77.IES 30' 20.00 10.00 5.00 2.00 1.00 35' 14.69 7.35 3.67 1.47 0.73 40' 11.25 5.63 2.81 1.13 0.56 45' 8.89 4.44 2.22 0.89 0.44 50' 7.20 3.60 1.80 0.72 0.36 3 BEAM AVAILABILITY AND LAMP ORIENTATION 2 Distribution Type (HxV) HPS MH Orientation 7x6 • • Vertical 1 6x5 Cutoff • Horizontal 6x2 • • Horizontal 5x5 Cutoff • Horizontal 0 4x4 • Vertical 4x3 • Vertical 1 2x4 • Vertical 2x3 • Vertical 1x2 • Vertical A B C D E 01 YOKE MOUNT TRUNNION MOUNT 1 1/2" [38mm] 3 1/2" [89mm] 2" [51mm] 5 3/8" [137mm] 3 3/4" [95mm] 1 7/8" 7/8" [22mm] dia. hole 1" [25mm] 9/16" [14mm] dia. hole (2) [48mm] Cooper Lighting STREETWORKS Outdoor Lighting Solutions 143 ...
Escreva a sua própria avaliação do dispositivo
|
|