Log:
Assessments - 4, GPA: 5 ( )

Instruções de Operação Invacare, Modelo IH6300

Fabricante : Invacare
Arquivo Tamanho: 1.77 mb
Arquivo Nome : 1096926.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


ICCG recommends use of the Traverse Lift Model 1200 ONLY. Bath lifts designed by other manufacturers are NOT to be utilized with the Supine Tub. Use of these products is prohibited and will void ICCG’s Supine Tub warranty. Use ONLY Traverse Lift Model 1200 to maintain resident safety and product utility. Refer to the lift owner’s manual for complete life operating and safety instructions. NEVER operate whirlpool without water level above the whirlpool jets. Severe pump damage will result. DO NOT operate this unit without the guard over the (water intake) suction fitting. The guard is a safety device that reduces the potential hazard of hair or body entrapment. To reduce the risk of injury, DO NOT permit children or infirm persons to use this unit unless they are supervised at all times. Recommended length of a bath is 5 to 10 minutes. However, if you become nauseous or dizzy or develop a headache, get out at once and cool down. Get medical attention if symptoms persist. Also, check with a physician before using this unit again. Anyone under a doctor.s supervision, pregnant, or with poor health, should check with a physician before using this unit. DO NOT use directly after eating or while under the influence of alcohol or drugs. Part No 1096926 11 Supine Bath Tub SECTION 2—DISINFECTING THE TUB SECTION 2—DISINFECTING THE TUB WARNING Disinfect the tub after EACH use to avoid resident infection and contamination of the tub. DO NOT disinfect the tub when it is occupied otherwise injury may occur. Read and understand all information on Invacare brand disinfectant before use. ALWAYS wear rubber gloves, an apron and a face shield when using disinfectant. In case of eye or skin contact, follow procedures on disinfectant container. The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant with a dilution ratio (. oz. per gallon) or viscosity level different than that of Invacare disinfectant will result in an improper mixture of disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using any disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of disinfectant to another type, the disinfectant flowmeter MUST be calibrated before performing this procedure. Refer to Calibrating the Disinfectant Flowmeter on page 28. DO NOT use the disinfectant wand for showering. The disinfectant wand is to be used for disinfecting ONLY. CAUTION NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners will make the gel-coat finish of your tub scratched and dull. NEVER use cleaners containing iodine, bromine, Betadine or methylene blue. The use of these types of cleaners will cause the tub to stain. Never use cleaners containing bleach. Use of these types of cleaners will dry out the rubber seals and gaskets and the tub will not function properly. Disinfecting the Tub Using the Closed Loop System NOTE: For this procedure, refer to FIGURE 2.1. NOTE: Ensure that the whirlpool jets and whirlpool inlet fitting are closed before starting this procedure. 1. Clean the entire tub surface to remove visible tissue residue and fluid. 2. Depending on the type of whirlpool jets that are in your tub, close all jets by performing one of the following: • Turn the center of the jet clockwise to a full stop. • Push the center of the jet in. 3. Close the whirlpool inlet by gently pulling the plug in the center of the inlet cover outward until it stops. 4. Open aerator by rotating aerator knob two turns counter.clockwise. 5. Open disinfectant cabinet on the top of the tub. DETAIL “A” - Whirlpool Jet 6. Ensure that disinfectant siphon tube is placed in WHIRLPOOL JET disinfectant container. AND INLET DETAILS 7. Hold the disinfectant wand over the interior of the tub. Push In To Close 8. Adjust water temperature to 105°F (40°C). Turn Clockwise 9. Turn disinfectant On/Off valve to the On position. to Close NOTE: Liquid will begin flowing from the disinfectant wand intothe tub. Whirlpool Inlet 10. Turn the adjustment knob on the flow meter until the Plug floating ball rises to a level of 35 cc/min. NOTE: At 35 cc/min., disinfectant is being mixed with water atthe proper ratio. 11. Continue to hold the disinfectant wand over the interior of the tub. NOTE: When disinfectant has totally filled the interior plumbing, liquid will begin to flow from the disinfectant wand. NOTE: Invacare recommends that you thoroughly scrub allinterior surfaces of the tub with disinfectant. The use of a long. handled brush will make this operation easier. Disinfectant 12. Spray the interior surfaces of the tub, including the Siphon Tube whirlpool jets, overflow fitting and whirlpool inlet fitting with disinfectant. Scrub all interior surfaces. Disinfectant 13. Turn the disinfectant On/...

Este manual também é adequado para os modelos :
Outros acessórios para a casa - IH6300ADH (1.77 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias