For best performance, mount the fixture about 8 ft.(2.4 m) above the ground.NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance. Wall Mount Eave Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. For eave mount only: . Swing the sensor head towards the clamp screw joint. Controls Clamp Screw . Then rotate the sensor head clockwise 180° so the controls face down. Controls Controls If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. 2 598-1094-04 Wire the Light Control WARNING: Turn power off at circuit breaker or fuse. . Remove the existing light fixture. . Installthemountingstrapasshownusingtwoscrews that fit your junction box. . The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. . Route the light control’s wires through the large gasket holes. . Twistthejunctionboxwiresandfixturewirestogether as shown. Secure with wire connectors. White to WhiteBlack to BlackJunctionboxgroundwiretogreengroundscrewonfixture. Gasket Mounting Strap Mounting Bolt Rubber Plug Mount the Light Control . Align the light control cover plate and cover plate gasket. Secure with the mounting bolt. . Align the three slots in the decorative shell with the bulb holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell. Shell Slot . Push the rubber plug firmly into place. . If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant. To avoid water damage and electrical shock, keep bulb holders 30° below horizontal. Keep bulbs at least 1" (25 mm) from the Lock Nut sensor.Do not allow the bulbs to block Lens the lens. . Adjustthebulbholdersbylooseningthelocknutsbut do not rotate the bulb holders more than 180° from thefactorysetting.Whenscrewinginthefloodlamps, do not overtighten. 598-1094-04 3 TEST AND ADJUSTMENT . Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes. . Turn the RANGE control to the medium position (halfway between MIN and MAX), Dual Light Level to OFF, and the ON-TIME control to the TEST position. BO O S T MAX MIN RANGE ON - TIME DUAL BRITE TEST 1 5 2 0 MINUTES OFF 3 6 DUSK TO HOUR DAWN DUAL LIGHT LEVEL Bottom of Sensor Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. 8 ft. (2.4 m) 70 ft. 100 ft. (21 m) (30.5 m) Boosted 240° Maximum Range Maximum Coverage Angle NOTE: Iffixtureismountedhigherthan8ft.(2.4m),aiming the sensor down will reduce coverage distance. The detector is less sensitive to motion directly towards it. Sensor Motion Motion Least Sensitive Most Sensitive . Loosen the clamp screw in the sensor ball joint and gently rotate the sensor. . Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times whenmotionisdetected).Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (25 mm) away from the bulbs. . Adjust the RANGE as needed. RANGE set too high may increase false triggering. . Secure the sensor head by tightening the clamp screw. Do not overtighten the screw. Clamp Screw Ball Joint Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Coverage . Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes). . Set the Dual Light Level switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn). WARNING: Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m). 4 598-1094-04 SPECIFICATIONS Range ............Up to 70 ft. (21 m); 100 ft. (30.5m)withRangeBoost.[varies with surrounding temperature] Sensing Angle...... Up to 240° Electrical Load. . . . . . Up to 300 Watt Maximum Incandescent [Up to 150 Watt maximum each bulb holder.] Power Requirements . 120 VAC, 60 Hz Replacement Lamp . . Upto150WattMaximumPAR38 Incandescent or Halogen (Not CFL) Bulbs. Operating Modes. . . . TEST, AUTO and MANUAL MODE Time Delay ........1, 5, 20 minutes Dual Light Level. . . . . 3, 6 hours, Dusk-to-Dawn Atlas Lighting Products, Inc. reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products prev...