|
Instruções de Operação Grizzly, Modelo G0548
Fabricante : Grizzly Arquivo Tamanho: 4.57 mb Arquivo Nome : e44a1ae8-122b-6e24-e500-bdecbabb94f9.pdf
Língua de Ensino:
|
|
|
|
Ir para baixar
Facilidade de uso
It represents our latest effort to produce the best documentation possible. If you have any comments or criticisms that you feel we should address in our next printing, please write to us at: Grizzly Industrial, Inc. % Technical Documentation P.O. Box 2069 Bellingham, WA 98227 Most important, we stand behind our machines. We have excellent regional service departments at your disposal should the need arise. If you have any service questions or parts requests, please call or write to us at the location listed below. Grizzly Industrial, Inc 1203 Lycoming Mall Circle Muncy, PA 17756 Phone:(570) 546-9663 Fax:(800) 438-5901 E-Mail: techsupport@grizzly.com Web Site: The specifications, drawings, and photographs illustrated in this manual represent the Model G0548 as supplied when the manual was prepared. However, owing to Grizzly’s policy of continuous improvement, changes may be made at any time with no obligation on the part of Grizzly. For your convenience, we always keep current Grizzly manuals available on our website at Any updates to your machine will be reflected in these manuals as soon as they are complete. © G0548 2 HP Dust Collector -5- SECTION 3: CIRCUIT REQUIREMENTS Amperage Draw Plug-Type The Model G0548 features a single phase 220V 2 HP motor. Amperage Draw 220V .................................................... 12 Amps Circuit Breaker Use the following guidelines when choosing a circuit breaker (circuit breakers rated any higher are not adequate to protect the circuit): Circuit Breaker 220V ..........................................15 Amp, 2 Pole We recommend using a NEMA 6-15 plug (Figure 1). You may also “hard-wire” the dust collector directly to your panel, provided you place a disconnect near the machine. Check the electrical codes in your area for specifics on wiring requirements. The motor is wired according to the diagram in Figure 1a. Figure 1. NEMA 6-15 plug and receptacle. -6- G0548 2 HP Dust Collector Grounding Circuit Capacity Awarning Electrocution or a fire can result if the machine is not grounded correctly. Make sure all electrical circuits are grounded. DO NOT use the machine if it is not grounded. NOTICE The wire on the power cord with green or green and yellow striped insulation is the grounding conductor. In the event of an electrical short, grounding reduces the risk of electric shock by providing a path of least resistance to disperse electric current. This tool is equipped with a power cord that has an equipment-grounding prong. The outlet must be properly installed and grounded in accordance with all local codes and ordinances. o= Always check to see if the wires in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician. If the circuit breaker trips or the fuse blows regularly, your machine may be operating on a circuit that is close to its amperage draw capacity. However, if an unusual amperage draw does not exist and a power failure still occurs, contact a qualified electrician. o Extension Cords We do not recommend the use of extension cords with 220V equipment. Instead, arrange the placement of your equipment and the installed wiring to eliminate the need for extension cords. Should the situation be necessary to use an extension, make sure the cord is rated Standard Service (grade S) or better. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged. G0548 2 HP Dust Collector -7- SECTION 4: MACHINE FEATURES Figure 2. Main view of machine features. 1. Canister Filter Cleaning Handle 2. Canister Filter 3. 6" Inlet with Three 4" Ports 4. Clear Collection Bag -8- G0548 2 HP Dust Collector SECTION 5: SET UP Awarning This machine presents serious injury hazards to untrained users. Read through this entire manual to become familiar with the controls and operations BEFORE starting the machine! Awarning Wear safety glasses during the entire set up process! Awarning The Model G0548 is a heavy machine (165 lbs. shipping weight). DO NOT over-exert yourself while unpacking or moving your machine—get assistance. Unpacking Your machine left our warehouse in two carefully packed boxes. If you discover the machine is damaged after you have signed for delivery, please immediately call Customer Service at (570) 546-9663 for advice. Save the containers and all packing materials for possible inspection by the carrier or its agent. Otherwise, filing a freight claim can be difficult. When you are completely satisfied with the condition of the shipment, you should inventory the equipment. p= Inventory After all the parts have been removed from the two boxes, you should have the following items: Box 1: Canister Filter Components (Figure 3) A. Canister Filter..........
Escreva a sua própria avaliação do dispositivo
|
|