Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Grizzly, Modelo G9955

Fabricante : Grizzly
Arquivo Tamanho: 1.29 mb
Arquivo Nome : g9955_m.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


1 —Phillips Head Screw M6-1.0 x 20 .......... 2 —Plastic Handle.........................................1 In the event that any non proprietary parts are missing (e.g. one or two bolts), we would be glad to replace them, or replacements can also be obtained at your local hardware store. Assembly Hardware and Components Needed Qty Phillips Head Screw M6-1.0 x 20 ...................... 2 Plastic Handle ................................................... 1 Clear Plastic Hood Top ..................................... 1 Clear Plastic Hood Sides .................................. 2 Tools Needed Qty Phillips Head Screwdriver ................................. 1 To Assemble the dust filter: 1. Attach the handle to the top of the filter with the Phillips head screws. 2. Attach the clear plastic sides and top to the filter with the hook and loop strips as shown in Figure 3. Figure 3. Clear plastic hood attachment detail. G9955 Bench Top Dual Fan Dust Filter -7 SECTION 5: OPERATIONS The Model G9955 Bench Top Dual Fan Dust Filter is designed specifically to filter fine airborne dust paticles. The operator can adjust the clear plastic hood to better channel the airborne dust from the workpiece into the bench top filter. Typical applications for the bench top filter are to collect dust from small wood carving and sanding tools with both power and manual operation. Operations that generate large amounts of any kind of dust may warrant the use of a respirator even though the dust filter is running. The dust filter is not a substitute for a respirator! THIS DUST FILTER IS TO BE USED FOR WOOD DUST ONLY. DO NOT use this machine to filter toxic fumes or paint spray. DO NOT use this machine to dissipate smoke or fumes. -8-G9954 Bench Top Dual Fan Dust Filter SECTION 6: MAINTENANCE !To avoid personal injury, disconnect power to air filter when performing any adjustments, clean- ing or maintenance. Use a respirator when cleaning or changing filters. Dust will become airborne creating a respiratory hazard. For safety, run the hanging air filter for at least 6 minutes while wearing the respirator after cleaning. Changing the Filter In order to maintain optimal operation, the filter in the Model G9955 should be checked and replaced regularly. Checking the filters once a week in a small home shop is a good habit. Checking it once a day during heavy use is important. Always wear a respirator when checking the filter. To check or replace the filter: 1. Disconnect power to the bench top air filter. 2. Pull the filter out of its housing and hold it up to a light source. —If light shines through the filter, shake it off in the garbage and reinstall. —If no light can be seen, replace the filter. Please see the current Grizzly catalog for the replacement filter H4985. G9955 Bench Top Dual Fan Dust Filter -9 SECTION 7: REFERENCE INFO The following pages contain the parts list, parts breakdown diagram, wiring diagram, and the Warranty/Return information for the Model G9955. If you have any comments regarding this manual, please write to Grizzly at the address below: Grizzly Industrial, Inc. C/O Technical Documentation P.O. Box 2069 Bellingham, WA 98227-2069 We recommend you keep a copy of our current catalog for complete information regarding Grizzly's warranty and return policy. If you need additional technical information, general assistance or replacement parts relating to this machine, please contact the Service Department at the location listed below: Grizzly Industrial, Inc. 1203 Lycoming Mall Circle Muncy, PA 17756 Phone: (570) 546-9663 Fax: (800) 438-5901 E-Mail: techsupport@grizzly.com Web Site: Aftermarket Accessories Grizzly carries a complete selection of fine accessories for all of its equipment. Below is a list of useful replacement filters and accessories. • H4985 Replacement Paper Filter -10-G9954 Bench Top Dual Fan Dust Filter G9955 Wire Diagram 110 Volt Outlets Fan Switches 110 VOLTS NEUTRAL GROUND Fans Disconnect power from machine before performing any electrical service. Failure to do this will result in a shock hazard leading to injury or death. G9955 Bench Top Dual Fan Dust Filter -11 G9955 Parts List REF PART # DESCRIPTION P9955001 MAIN HOUSING P9955002 REAR HOUSING COVER P9955003 5 MICRON FILTER 20" x 10" x 2" P9955004 CLEAR PLASTIC HOOD TOP P9955005 CLEAR PLASTIC HOOD SIDE P9955006 FAN P9955007 SWITCH PWRCRD110L POWER CORD P9955009 STRAIN RELIEF 6W3-4S PN04M HEX NUT M4-.7 PS85M PHLP HD SCR M4-.7 x 60 PS38M PHLP HD SCR M4-.7 x 10 P9955013 HANDLE PS26M PHLP HD SCR M6-1 x 20 P9955015 LOOP FASTENER 5/8" x 9-1/2" P9955016 LOOP FASTENER 1" x 7" P9955017 HOOK FASTENER 5/8" x 21" P9955018 HOOK FASTENER 5/8" x 9-1/2" P9955019 LOOP FASTENER 5/8" x 18" P9955020 HOOK FASTENER 1" x 3" P9955021 110V OUTLET S-15R P9955022 GROUNDING WIRE P9955023 110 VOLT WIRE P9955023 NEUTRAL WIRE -12-G9954 Bench Top Dual Fan Dust Filter G9955 Bench Top Dual Fan Dust Filter -13- G9955 Parts Breakdown 2 12 11 6 7 13 14 1 22 23...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias