Log:
Assessments - 5, GPA: 3.6 ( )

Instruções de Operação Philips, Modelo SPO2 M1191A

Fabricante : Philips
Arquivo Tamanho: 2 mb
Arquivo Nome : Resuable_SpO2_Sensors_Instructions_for_Use__IFU___multi-language_1_.pdf
Língua de Ensino: ruplsvitentresfrdebgetslnlhuptskdaficslvltro
Ir para baixar



Facilidade de uso


Contents Instructions for Use............... 1 Manuel d’utilisation............ 10 Gebrauchsanweisung .......... 19 Gebruiksaanwijzing ............ 28 Instrucciones de Uso........... 37 Instrucoes de Uso................ 46 Istruzioni d’uso ................... 55 Bruksanvisning ................... 64 Bruksanvisning ................... 73 Kayttoopas .......................... 82 Brugerhandbog.................... 91 Hasznalati utmutato .......... 100 Instrukcja obslugi.............. 109 Navod na pouziti............... 118 Printing History Current Edition/Revision: Printed in Germany December 2006 Previous Editions/Revisions: Printed in Germany June 2006 Edition 1, Revision E.00.00 Printed in Germany August 2004 Edition 1, Revision D.00.00 Printed in Germany December 2003 Navod na pouzitie ............. 127 Navodila za uporabo ......... 136 Instructiuni de utilizare ..... 145 Инструкции за употреба. 154 Kasutusjuhend................... 163 Naudojimo instrukcija....... 172 Lietosanas noradijumi....... 181 Инструкция по эксплуатации 190 ....... ...................... 199 Kullan.m Talimatlar.......... 208 ......... ........ 217 ................. 226 ................ 236 United States law restricts this device to sale by or on the order of a physician. OxiMax® is a registered trademark of Tyco Healthcare Group LP, Nellcor Puritan Bennett Division. Product Overview Three series of Philips reusable SpO2 sensors offer monitoring capability for a broad range of patient types as shown in the table below. Reference Specifications later in this IFU for sensor accuracy. • A-Series Sensors: For use with any Philips/Agilent/HP instrument that lists them as an accessory. Refer to your instrument’s Instructions for Use for A-Series sensor compatibility information. • B-Series Sensors: For use with the same Philips/Agilent/HP instruments that list A-Series M1191A and M1191AL sensors as compatible accessories; i.e. M1191B can replace M1191A and M1191BL can replace M1191AL. • Special Edition A-Series Sensors (AN-Series): For use with Philips brand OxiMax® compatible instruments M1020B or M3001A, Option A02. Also for use with the same Philips/Agilent/HP instruments that list A-Series sensors as compatible accessories. Each Special Edition A- Series sensor can replace its similarly numbered A-series sensor; i.e. M1191ANL can replace M1191AL; M1192AN can replace M1192A; M1193AN can replace M1193A; M1194AN can replace M1194A; and M1195AN can replace M1195A. A-Series Sensors B-Series Sensors 2Special Edition A-Series Sensors Adult Pediatric Infant Neonate Finger Ear Finger Ear 3Finger Toe 3Hand Foot M1191A M1191B N/A • 1M1191AL 1M1191BL 1M1191ANL • M1192A N/A M1192AN • M1193A N/A M1193AN • • M1194A N/A M1194AN • • M1195A N/A M1195AN • • 1These sensors have a Longer 3m (versus standard 2m) attached cable. 2These sensors extend compatibility to Philips brand OxiMax® compatible instruments. 3Preferred application sites for M1193A and M1195A sensors. 1 Intended Use Philips reus...

Este manual também é adequado para os modelos :
Outras ferramentas - SPO2 M1191AL (2 mb)
Outras ferramentas - SPO2 M1191ANL (2 mb)
Outras ferramentas - SPO2 M1191B (2 mb)
Outras ferramentas - SPO2 M1191BL (2 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias