|
por este dispositivo também tem outras instruções :
Facilidade de uso
Then, restart the system. 2.5 VMware Setup Notes - To install ICP Storage Manager on the VMware ESX Server: 1. Insert the ICP Storage Manager application CD into the CD-ROM drive. 2. Type the following command to install the 32-bit Linux ICP Storage Manager on the VMware ESX Server: rpm -ivh RaidMan-8.40.i386.rpm 3. Install ICP Storage Manager on a Windows or Linux machine. 4. From the Windows or Linux client, connect to the ICP Storage Manager agent on the VMware ESX Server using the ISM GUI. - The ICP Storage Manager agent on the VMware ESX Server cannot be monitored from a guest operating system. - The VMware ESX Server firewall must have specific ports enabled for incoming and outgoing traffic. The default ports ICP Storage Manager uses for connection are 34570 to 34580. -------------------------------------------------------------------- 3. ICP Storage Manager Cautions and Notes 3.1 General Cautions - While an array is being built or cleared, do not remove and reinsert any drive from that array. Doing so may cause unpredictable results for any of the controller's arrays. - While a drive is being cleared, do not try to include it in a new array. Doing so may cause unpredictable results. - Do not move drives containing an array or volume from one controller to another while the power is on. Doing so could cause the loss of the array configuration or data, or both. Instead, power off both affected controllers, move the drives, and then restart. - When using ICP Storage Manager and the CLI concurrently, configuration changes may not appear in the ICP Storage Manager GUI until you refresh the display (by pressing F5). 3.2 General Notes - ICP Storage Manager requires that the following range of ports be open for remote access: 34571 - 34575. - ICP Storage Manager generates log files automatically to assist in tracking system activity. The log files are created in the directory where the ICP Storage Manager is installed. o RaidEvt.log - Contains the information reported in the ICP Storage Manager event viewer for all local and remote systems. o RaidEvtA.log - Contains the information reported in the ICP Storage Manager event viewer for the local system. o RaidNot.log - Contains the information reported in the Notification Manager event viewer. o RaidErr.log - Contains Java messages generated by ICP Storage Manager. o RaidErrA.log - Contains Java messages generated by the ICP Storage Manager agent. Information written to these files is appended to the existing files to maintain a history. However, if any of the files reach a size of 200,000 bytes, the file is copied to a new file with the extension .OLD and the original (that is, the LOG file) is deleted and recreated. If a .OLD file already exists, the existing .OLD file is destroyed. - The blink LED feature is supported only in SAF-TE enabled enclosures. - In the Event viewer, ICP Storage Manager reports both the initial build task for an array, and ...
Este manual também é adequado para os modelos :Outros componentes - ICP9047MA (31.05 kb)
Outros componentes - ICP5805BL (31.05 kb)
Outros componentes - ICP5125BR (31.05 kb)
Outros componentes - ICP5085BR (31.05 kb)