Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Adaptec, Modelo Adaptec Serial ATA RAID 1210SA

Fabricante : Adaptec
Arquivo Tamanho: 29.78 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Doing so may cause unpredictable results. - Do not move drives containing a pool or volume from one controller to another while the power is on. Doing so could cause the loss of the pool configuration or data, or both. Instead, power off both affected controllers, move the drives, and then restart. - When using Adaptec Storage Manager and the CLI concurrently, configuration changes may not appear in the Adaptec Storage Manager console until you refresh the display (by pressing F5). 3.2 General Notes - Adaptec Storage Manager requires that the following range of open ports for remote access: 34570-34580. - Adaptec Storage Manager generates log files automatically to assist in tracking system activity. The log files are created in the directory where the Adaptec Storage Manager is installed. o RaidEvt.log - Contains the information reported in the Adaptec Storage Manager event viewer for all local and remote systems. o RaidEvtA.log - Contains the information reported in the Adaptec Storage Manager event viewer for the local system. o RaidNot.log - Contains the information reported in the Notification Manager event viewer. o RaidErr.log - Contains Java messages generated by Adaptec Storage Manager. o RaidErrA.log - Contains Java messages generated by the Adaptec Storage Manager agent. Information written to these files is appended to the existing files to maintain a history. However, if any of the files reach a size of 200,000 bytes, the file is copied to a new file with the extension .OLD and the original (that is, the LOG file) is deleted and recreated. If a .OLD file already exists, the existing .OLD file is destroyed. - The blink LED feature is supported for management-processor-enabled enclosures only. - In the Event viewer, Adaptec Storage Manager reports both the initial build task for a pool and a subsequent Verify/Fix as a "Build/Verify" task. - Task priority is not retained after rebooting. If you change a priority to LOW or MEDIUM, and reboot, the controller resets the priority to the default (HIGH). - When a pool fails, the pool name returns to its default name. - When displaying information about a physical device, the device, vendor and model information may be displayed incorrectly. - After using a hot spare to successfully rebuild a redundant pool, information about the hot spare drive may not display as expected. Adaptec Storage Manager may continue to display it as a global hot spare. -------------------------------------------------------------------- 4. Operating System-Specific Issues and Notes 4.1 All - Adaptec Storage Manager will not start on a system that uses only 16 colors. Adaptec Storage Manager supports a minimum of 256 colors. You must switch the video mode from 16 colors to a mode with at least 256 colors. - If the Adaptec Storage Manager console does not repaint correctly, select the View->Refresh menu item to repaint the screen. 4.2 Windows - All - The Java Virtual Machine has a problem with the 25...

Este manual também é adequado para os modelos :
Outros componentes - Adaptec Serial ATA II RAID 1220SA (29.78 kb)
Outros componentes - Adaptec RAID 4805SAS (29.78 kb)
Outros componentes - Adaptec RAID 4800SAS (29.78 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias