Log:
Assessments - 5, GPA: 3.8 ( )

Instruções de Operação ResMed, Modelo S8 AutoScore II

Fabricante : ResMed
Arquivo Tamanho: 220.8 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Note: The AutoSet menu is available on the S8 AutoSet Spirit II only. The Detailed Menu Your clinician may have enabled a detailed menu on your S8 Series II device. The figure below shows the detailed menu in each mode. To enter the detailed menu from the standby (RAMP or SETTLING) screen, press . CPAP RAMP: 10min menu WELCOME >>>>>> SETTINGS enter exit SETTLING: 10min menu WELCOME >>>>>> EPR LEVEL: 1 change exit MASK: ULTRA change exit TUBE LENGTH: 2m change exit HUMID: NONE change exit SMARTSTART: ON change exit LEAK ALERT: OFF change exit AUTOSET MASK: ULTRA change exit TUBE LENGTH: 2m change exit HUMID: NONE change exit SMARTSTART: ON change exit LEAK ALERT: OFF change exit AUTOSET CPAP USED HRS: 08000 exit USAGE: 1000/1068 exit RESULTS enter exit SERVICING enter exit OPTIONS enter exit LANG: ENGLISH change exit SN: 12345678912 exit PCB: 123456789123 4567 exit SW: SX4800100 exit SMART DATA enter exit SMART DATAAUTO APPEAR: OFF enter exit change cancel EPR LEVEL: 1 change exit * ** * * * Only displayed if access set by clinician. Note: The AutoSet menu is available on the S8 AutoSet Spirit II only. Changing the Settings on your S8 II Device Messages on the S8 Series II LCD Your clinician may have set your S8 Series II device to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled) and so on. The reminder message is displayed on the LCD and is visible if the device is not delivering therapy. The backlight on the LCD flashes when a message is displayed. Your clinician can set any of the following reminders on your LCD: Message Description Action INSERT May appear if your device is Insert your Data Card and follow any CARD Data Card enabled. instructions that your clinician has given you. When you have done this, the message will disappear from the LCD. Pressing (Ok) will also remove the message. REPLACE May appear when your mask Press (Ok) to remove the message MASK is due for replacement. from your LCD, and replace your mask with a new one. CALL May appear as a reminder to Press (Ok) to remove the message PROVIDER contact your clinician, eg, to from your LCD, and contact your clinician. discuss how your therapy is going. REPLACE May appear as a reminder to Press (Ok) to remove the message FILTER replace the air filter on your from your LCD, and replace the air filter. device. SERVICE May appear as a reminder to Press (Ok) to remove the message DUE return your device for service. from your LCD, and contact your clinician. Using the Data Card to Collect Data If your clinician needs to review your treatment, they will ask you to use the Data Card to copy data from your S8 Series II, and to return the card to them. Copying Data onto the Data Card 1 Switch on the S8 Series II and wait until you see the standby (Ramp or Settling) screen. 2 Hold the Data Card with the arrow facing up and insert it into the Data Card slot until it stops. Data copying starts automatically. The “Card Inserted Please Wait” message is displayed on the S8 Series II LCD while data is being copied. Copying takes approximately five seconds. The “Copy Complete Remove Card” message is displayed on the LCD when copying has finished. ! 3 Remove the Data Card by gripping the end of the Data Card and pulling it out. 4 Store the Data Card in its protective folder when not in use. 5 Return the card in its protective folder to your clinician using a postal envelope. Updating Settings on your S8 device If your clinician has provided a Data Card with new device settings: 1 With the device in standby (Ramp or Settling) mode, insert the Data Card into the Data Card slot. Updating will start automatically. The “Card Inserted Please Wait” message is displayed on the LCD while updating is in progress. Updating takes approximately five seconds. The “Settings Success Remove Card” message is displayed on the LCD if the settings were updated successfully. Note: This message only appears once. If you re-insert the Data Card after you have updated your settings, this message is not displayed. 2 Remove the Data Card from the S8 Series II. 3 Store the Data Card in its protective folder when not in use. WARNING If your clinician has told you to use this Data Card to update the settings on your device and the “Settings Success” message does not appear, contact your clinician immediately. Cleaning and Maintenance Daily Disconnect the air tubing and hang it in a clean, dry place until next use. Weekly 1 Remove the air tubing and wash it in warm water using mild detergent. 2 Rinse thoroughly, hang, and allow to dry. 3 Before next use, reassemble the mask and headgear. 4 Reconnect the air tubing. Monthly 1 Clean the exterior of the S8 Series II with a damp cloth and mild liquid soap. 2 Check the air filter for holes and blockage by dirt. Cleaning and Maintenance WARNING ! Beware of electric shock. Do not immerse the device or power cord in water. Always unplug the device before cleani...

Este manual também é adequado para os modelos :
Outros dispositivos pessoais - S8 Series II (220.8 kb)
Outros dispositivos pessoais - Positive AirwAy Pressure Device S8 Series II (220.8 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias