Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Teledyne, Modelo TED 191

Fabricante : Teledyne
Arquivo Tamanho: 125.2 kb
Arquivo Nome : 45bf8bd9-7c6a-4b45-948d-91e3c4f6684b.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. . TYPE B EQUIPMENT: Equipment providing a particular degree of protection against electric shock, particularly regarding— • allowable LEAKAGE CURRENT • Reliability of the protective earth connection (if present). P/N TM0021 04/03/00 ECO # 00-0086 TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments COPYRIGHT © 1996 TELEDYNE ELECTRONIC TECHNOLOGIES – ANALYTICAL INSTRUMENTS All Rights Reserved No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, manual, or otherwise, without the prior written consent of Teledyne Electronic Technologies Analytical Instruments, 16830 Chestnut Street, City of Industry, CA 91749-1580 Phone (626) 934-1500 FAX (626) 961-2538 Technical Support: (626) 934-1673 TWX (910) 584-1887 TDYANLY COID or your local representative. WARRANTY STATEMENT The electronic control and display components of the TED 191 Portable Oxygen Monitor are warranted against defective workmanship and materials for 24 months from date of shipment from Teledyne. The class T-7 Micro-Fuel Cell is warranted for one year from the date of shipment from Teledyne. The liability of Teledyne, if any, shall be limited solely to the replacement and repair of the goods, and shall not include shipping costs or other incidental damages as defined in Section 2-715 of the U.S Uniform Commercial Code. This warranty is null and void if any goods are subjected to misuse, negligence, accident or repairs other than those performed by Teledyne or an authorized service center. Caution: Federal Law restricts this device to sale by or on the order of a physician. TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments TABLE OF CONTENTS SECTION TOPIC PAGE NUMBER INTRODUCTION 4 APPLICATIONS DESCRIPTIONS OF FUNCTIONAL ZONES: FRONT PANEL 6 REAR PANEL 7 1. OPERATIONS: 1.1 SET-UP 8 1.2 INSTALL THE BATTERIES 9 1.3 INSTALL THE SENSOR 1.4 CALIBRATE THE INSTRUMENT 11 1.5 NORMAL OPERATION 12 1.6 SET THE ALARMS 13 2. ANAESTHETIC AGENTS 14 3. CLEANING 4. DO’S AND DON’T’S 16 5. ROUTINE MAINTENANCE . 17 6. TROUBLESHOOTING 18 7. TECHNICAL SPECIFICATIONS 8. EFFECT OF PRESSURE 22 9. EFFECT OF HUMIDITY 23 10. EFFECT OF TEMPERATURE 24 11. DISCREPANCY IN READING 12. REPAIR SERVICE 26 SENSOR CELL REPLACEMENT LOG 27 TECHNICAL SERVICE LOG 28 GENERAL NOTES 29 SPARE PARTS LIST TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments INTRODUCTION The TED 191 Portable Oxygen Monitor is an easy-to-use, portable instrument that provides fast and accurate oxygen monitoring and audio-visual alarm capability. The TED 191 is designed to monitor concentrations of up to 100% oxygen in medical gas mixtures. The TED 191 Portable Oxygen Monitor is designed and manufactured in accordance with strict performance and quality protocols and subject to ISO 9002 Quality System protocols. When used correctly, this instrument will provide you with many years of trouble free service. The TED 191 Portable Oxygen Monitor is a compact, self-contained unit, which is battery powered by four (4) dry cell batteries (size AA/penlight). TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments APPLICATIONS The instrument is designed for the measurement of oxygen concentrations in a variety of medical gas mixtures. It is recommended that the instrument be used only as a secondary measuring device to verify the concentration of oxygen in gas mixtures prepared using a gas blender or similar apparatus. The use of this monitor as a primary or only means of preparing gas mixtures is not advised. The monitor is capable of verifying oxygen concentrations in gas mixtures used in: • Anesthesia • Neonatal Intensive care • Adult Intensive care • Respiratory / Oxygen Therapy TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments DESCRIPTION OF FUNCTIONAL ZONES FRONT PANEL High Alarm Setting Knob Alarm Mute Button Calibration Control 50 60 40 70 TELEDYNE 30 80 HI 21 90 102 50 60 X 21 40 70 30 80 LO % OXYGEN 21 90 OXYGEN MONITOR I O 102 Low Alarm Setting Knob Liquid Crystal Display (LCD) On / Off Switch On / Off Switch Allows the operator to turn the instrument on and off. Alarm Mute Switch Allows the operator to “mute” the sound of the audible alarm signal for ± 60 seconds. During this time, a red signal lamp will flash, indicating a “muted” alarm condition is in force. Calibration Control Allows the operator to calibrate the instrument to one primary set point (usually 100%) in accordance with the designated calibration protocol. This protocol is defined further in this manual and also. Instructions in abbreviated form can be found on the top of the monitor casing. High Alarm Setting Allows the operator to define a high alarm threshold limit. Range 18% to 102% - if the actual measured value as displayed on the LCD exceeds this set threshold, an audible and visual alarm condition will be invoked. Low alarm sett...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias