Log:
Assessments - 3, GPA: 3 ( )

Instruções de Operação 3M, Modelo 7000 Series

Fabricante : 3M
Arquivo Tamanho: 586.79 kb
Arquivo Nome : C114-124.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Suitable for either negative or positive pressure uses, they can use filters and/or cartridges in a wide range of combinations to provide protection in numerous applications. All are available with complete spare parts. 3M respirators offer users an effective way of meeting OSHA requirements. Depending on your workplace application, 3M has a respirator with innovative features and technologies that workers will wear. Fax on Demand: 1 800 646-1655 7000 Series Document #4018 Features & Benefits • Available in 3 sizes (small, medium, large) to comfortably fit many faces. • Half facepieces have a four-point strap attachment with convenient front-strap adjustment. • N95, P95 or P100 filters can be used in combination with chemical cartridges. • Extra large inhalation and exhalation valves for easier breathing. • The full facepiece has double- flange face seal and six adjustable straps to help provide a secure fit, and improved fit-test results. • The full facepiece is available in 11 different modes from air purifying to SCBA. Suggested Applications • Painting • Welding • Abatement • Wood-working • Metal-working • Automotive manufacturing • Chemical manufacturing • Pharmaceutical manufacturing • Petrochemical • Nuclear • Utilities • Primary metals WARNING ! These respirators help reduce exposure to certain airborne contaminants. Misuse may result in sickness or death. Before use, the wearer must read and understand User Instructions provided as a part of product packaging. Time use limitations may apply. Call 3M OH&ESD Technical Service. 1 800 243-4630. Important Before using these respirators, you must determine the following: 1. The type of contaminant(s) for which the respirator is being selected. 2. The concentration level of contaminant(s). 3. Whether the respirator can be properly fitted on the wearer’s face. All respirator instructions, warnings and use and time limitations must also be read and understood by the wearer before use. Before use of these respirators, a written respiratory protection program must be implemented, meeting all the requirements of OSHA 29 CFR 1910.134, including training and fit testing. United States Technical Service 1 800 243-4630 Sales Assistance 1 800 896-4223 C114 Canada Technical Service 1 800 267-4414 Sales Assistance 1 800 265-1840 ext. 6137 2000 Resource Guide 3M™ Half and Full Facepiece Respirators with Bayonet Attachment 7000 Series 7001 Small 7800S Small 7002 Medium 7800S Medium 7003 Large 7800S Large Respiratory Protection Solutions Cartridges & Filters Facepieces worn with half facepiece respirators when used against 60921 P100/OV 60922 P100/AG 60923 P100/OV/AG 60924 P100/AM/MA 60925 P100/Form 60926 P100/Multi Gas 2071 P95 Filter 2076* HF/P95 Filter 2078** P95 Filter 2091 P100 Filter 2096*** P100 Filter 2097**** P100 Filter 5N11 5P71 N95 Filter P95 Filter 501 Retainer 502 Adapter Filter Retainers & Adapters 6001 OV 6002 AG 6003 OV/AG 6004 AM/MA 6005 Form 6006 Multi Gas * P95 filter with hydrogen fluoride and nuisance level acid gas relief. ** P95 filter with nuisance level organic vapor/acid gas relief. *** P100 filter with nuisance level acid gas relief. **** P100 filter with nuisance level organic vapor relief. NEW! # OSHA regulations require that gas-proof goggles be 6009 60929 7093 formaldehyde. P100 Filter Merc P100/Merc OV = NIOSH approval: Certain organic vapors. dioxide or hydrogen sulfide (escape only) Multi-Gas= NIOSH approval: Certain organic vapors, AG = NIOSH approval: Chlorine, hydrogen or hydrogen fluoride. chlorine, hydrogen chloride, chlorine chloride, and sulfur dioxide or chlorine AM/MA = NIOSH approval: Ammonia and dioxide, sulfur dioxide, hydrogen sulfide dioxide or hydrogen sulfide (escape only). methylamine. (escape only) ammonia/methylamine, OV/AG = NIOSH approval: Certain organic vapors, Form = NIOSH approval: Formaldehyde # and formaldehyde # or hydrogen fluoride. chlorine, hydrogen chloride, and sulfur certain organic vapors Merc = NIOSH approval: Mercury vapor or chlorine gas. United States Canada Technical Service 1 800 243-4630 Technical Service 1 800 267-4414 Sales Assistance 1 800 896-4223 C115 Sales Assistance 1 800 265-1840 ext. 6137 2000 Resource Guide Half and Full Facepiece Respirators with Bayonet Attachment 7000 Series Checklist for Building a Complete Respirator Assembly 1. Select full or half facepiece and • Do you need cartridges? 3. Select needed accessories based determine size: small, medium or large. See pages C119-C120. on your application. 2. Determine protection requirements. • If you need filters and cartridges, review See pages C121-C122. • Do you need filters, retainers or pages C117-C120. 4. For replacement parts, adapters? See pages C117-C118. see pages C123-C124. Half Facepiece Respirators with Bayonet Attachment 7000 Series 7001 (small), 7002 (medium), 7003 (large) These facepieces can be used with 2000 Series, 5000 Series, and 6000 Series cartridges, filters, retainers and adapters. Note: These facepieces als...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias