Log:
Assessments - 5, GPA: 4.2 ( )

Instruções de Operação Panasonic, Modelo PTD5500U

Fabricante : Panasonic
Arquivo Tamanho: 2.23 mb
Arquivo Nome : PTD5500U.PDF
Língua de Ensino: enfr
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit. If you continue to use a lamp after the replacement time, the lamp may break. Philips screwdriver is necessary when replacing a lamp unit. Take care not to slip your hand when using a screwdriver. Attention • A lamp unit is an optional part. Contact the dealer. Replacement lamp unit model No.: ET-LAD55 (single bulb), ET-LAD55W (double bulbs) Rating: 300W Long life lamp unit model No.: ET-LAD55L (single bulb), ET-LAD55LW (double bulbs) Rating: 160W • Other lamps than specified above cannot be used. Be sure to use the specified lamp. Timing of lamp unit replacement The lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500 hours 1 (when lamp output is HIGH and lamp selection is DUAL). However, it may happen that the lamp becomes dead (will not light) by the time of 1 500 hours 1 depending on the characteristics of individual lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals between previous lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare bulb. If your lamp unit is not replaced after 1 300 hours 2 (with the lamp output set at “HIGH”), power supply will be turned off automatically at the time of 1 500 hours 1, entering a standby state. After 1 500 hours 1 of initial lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is turned on again. Indication after 1 300 hours 2 (with the lamp output set at “HIGH”) When lamp unit used hours have reached 1 300 hours 2, lamp monitor (LAMP1 or LAMP2) light up including standby state. Further, an on-screen indication will appear for about 30 seconds as shown in the diagram on the left, recommending replacement of lamp unit. REPLACE THE LAMP (The indication on the left diagram will disappear after about 30 seconds or when either control button on the rear of main unit or remote control button is operated.) After the time of 1 500 hours 1, the on-screen indication will not disappear unless the menu (MENU) button is operated. 1 This time period is 4 000 hours when long life lamp units are used. 2 This time period is 3 800 hours when long life lamp units are used. 44 Replacing the lamp unit Lamp unit replacement steps • After 1 500 hours (4 000 hours when long life lamp units are used) of operating the same lamp, it is only possible to operate the unit for approximately 10 minutes. Steps to must be completed within 10 minutes. Attention Turn the power off by following the steps on page 23, remove the power plug and confirm that the surroundings of the lamp unit have cooled off. Check that the fan has stopped running. Have a Phillips screwdriver ready ahead of time. Remove the screw securing the lamp unit cover, and then slide the lamp unit cover a little toward the left, and remove it. Remove the two screws securing the fan unit. Lamp unit cover Open the fan unit as shown in the figure. Remove the screws securing the lamp units (two for each unit), take hold of the grips, and remove the lamp units. Install the new lamp unit. Use a Phillips screwdriver to securely tighten the 2 lamp unit fixing screws (two for each unit). Lamp unit 2 Handle Lamp unit 1 Lamp unit Fixing screws Secure the two screws for securing the fan unit tightly. Slide the cover a little toward the right, and secure it using the screw for securing the lamp unit cover tightly. • Firmly install the lamp unit and lamp unit cover. If not installed firmly, a protection circuit will function and the power will not be turned on. Attention • The lamp units are constructed in such a way that the screws in steps and will not fall through completely. Note Caution The lamp unit will be hot after it has been used. You might get burned if you touch it while it is still hot. MENU SYSTEM INFORMATION Insert the power cord plug into the wall outlet and then press the MAIN POWER switch. Attention • If the power does not turn on even after turning the MAIN POWER switch “I”, turn the MAIN POWER “O”, confirm that the lamp unit and door are installed correctly, and turn on again. LAMP TIME RESET LAMP1 LAMP2 LAD55 LAD55L LAD55 1433h 0h 1100h 0h LAD55L Press the “POWER” button so that a picture is projected onto the screen. Press the “MENU” button to display the MAIN MENU screen, and then press the and buttons to move the cursor to select “OPTION2”. Press the “ENTER” button to display the “OPTION2” screen, and select “SYSTEM INFORMATION” with the and buttons. Press the “ENTER” button. The SYSTEM INFORMATION screen will be displayed. Press and hold the “ENTER” button on the projector or the remote control for approximately 3 seconds. An item “LAMP TIME RESET” will be added. Select the lamp which has been replaced with the and buttons. LAMP1: Replace the LAMP UNIT 1 LAMP2: Replace the LAMP UNIT 2 Press the ENTER button, and when...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias