Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Furuno, Modelo FS-2570

Fabricante : Furuno
Arquivo Tamanho: 2.55 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


2) Enter the password. 3) Select LOAD DEFAULT and press the ENTER knob. 4) Select Yes and press the ENTER knob. 5) Press the CANCEL key to return to the menu screen. 6) Select MEM CLR from the menu screen and press the ENTER knob. 7) Select LOAD DEFAULT and press the ENTER knob. 8) Select Yes and press the ENTER knob. 9) Press the CANCEL key to return to the menu screen. 8. Turn off the power at the control unit. Note: If your system has two control units, do the steps 6) to 9) in step 7 from the second control unit. 3.3 Manual 2182 kHz Tuning Preset For safety measure, it is required that 2182 kHz be tunable both automatically and manually. The setup to enable manual tuning, in the event the antenna tuner system fails, is made with the DIP switches in the antenna coupler. Call a coast station and tell your situation. Be sure not to transmit during silent period (00 to 03 min. 30 to 33 min. of every hour). 1. Remove the top cover of the antenna coupler. Set the S1 switch (Coupler Board) to AUTO. DipSW S5 S6 (In case of FS-2570, under the shield plate) Dip SW S4 AUTOMANUAL Coupler Board S1 switch LED (CR1- CR8) LED (CR9-CR22) S1 switch on the COUPLER Board 2. Turn the transceiver unit on. 3. Press the [1/RT/2182] key down for two seconds. 4. Press the [LOG/TUNE] key. “TUNE” appears on the LCD. “TUNING: OK” appears when tuning is completed. Record the status (on or off) of LEDs CR1 – CR22 (on the COUPLER Board). 5. Set S1 switch to MANUAL. 6. Set S4, S5, S6 DIP switches so that LEDs become the status is the same as in step 4. The relations between the DIP switch and LED are shown on the next page. When a DIP switch is turned on, the appropriate LED lights. DIP switch LED No. LED status S4 #8 CR1 #7 CR2 #6 CR3 #5 CR4 #4 CR5 #3 CR6 #2 CR7 #1 CR8 S5 #8 CR9 #7 CR10 #6 CR11 #5 CR12 #4 CR13 #3 CR14 #2 CR15 #1 CR16 S6 #8 CR17 #7 CR18 #6 CR19 #5 CR20 #4 CR21 #3 CR22 7. Return the S1 switch to AUTO, confirming that LEDs do not change. If different, repeat step 6. 8. Set the S1 switch to MANUAL. 9. Making sure it is not silent time, communicate with the handset. Confirm that IA changes with voice level. 10. Set the S1 switch to AUTO. Close the cover of the antenna coupler. For technician Please pass on the following information to the customer. • When the auto tuning circuit is broken, transmission is available by the manual tuning (setting the S1 switch to MANUAL). • Do not change the settings of DIP switch in the antenna coupler. 3.4 System Setup Enter system settings as below after the installation. To prevent accidental transmission of the distress alert, disconnect the antenna. These settings should be entered by a qualified technician. The installer enters system settings on the System Setup menu. A password is required to access this menu. Under no circumstances shall the operator access the System Setup menu. 3.4.1 Opening the System Setup menu (DSC) 1. Press the [SETUP] key to display the Setup menu. 2. Rotate the [ENTER] knob to select “SYS SETUP”. 3. Enter the password referring to appropriate FURUNO INFORMATION to display the System setup menu. The password cannot be informed customers by statute. System Setup EQUIPMENT TYPE : 1570 PROTECTION : OFF DSC SYSTEM SETUP RT SYSTEM SETUP LOAD DEFAULT TEST System setup menu 3.4.2 DSC SYSTEM menu Choose “DSC SYSTEM SETUP” on the System setup menu, and then press the [ENTER] knob to show the DSC System setup menu. DSC System setup MMSI: xxxxxxxxx FIXED MODEM OUT : 0.0dBm SIG DET S LEVEL : 100 REGULATION : INTL CLASS : MF/HF DIST : PANEL1 2006-04-01 00:00:00 DSC System Setup menu MODEM OUT Adjust the level of the modem output for DSC board (DSC modem, NBDP modem). Normally, this setting is not required. SIG DET S LEVEL SIG DET S LEVEL judges whether the DSC frequency to use to send a DSC message is in use or not. The DSC message is not transmitted when the signal strength on the DSC frequency is higher than that set here. When the DSC frequency becomes clear, the DSC message is automatically transmitted. The setting range is OFF –255 and the default setting is 100. 1. Rotate the [ENTER] knob to select “SIG DET S LEVEL”. 2. Press the [ENTER] knob to display the S LEVEL pop-up window. S LEVEL (OFF 255) SIG DET S LEVEL pop-up window 3. Rotate the [ENTER] knob to adjust the indicator bar. Too low a setting stops transmission of a DSC message because it detects noise on the DSC frequency. Alternately, too high a setting transmits the DSC message though low signal level is present on the DSC frequency used. 4. Press the [ENTER] knob to finish. REGULATION Set the regulation to be used. 1. Rotate the [ENTER] knob to select “REGULATION”. 2. Press the [ENTER] knob. INTL RUSSIA Regulation pop-up window 3. Rotate the [ENTER] knob to select “INTL” or “RUSSIA”. Only for Russia registry, select “RUSSIA”. 4. Press the [ENTER] knob to finish. DIST Shows the last transmitted DISTRESS information. 3.4.3 RT System setup Choose “RT SYSTEM SETUP” on the System setup menu, and then press th...

Este manual também é adequado para os modelos :
Telefones com fio - FS-1570 (2.55 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias