Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação Clarke, Modelo FOCUS S20

Fabricante : Clarke
Arquivo Tamanho: 1.21 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


11. When you stop the machine, press the red "OFF" button or turn the key switch counterclockwise to the"OFF" position ("L" models only). Remove the keyand set the parking brake (if equipped). B How To Operate The Machine EN 5. When either the left or right forward/reverse switches(figure 28, item A) are pushed in, the machine will goforward ("L" models only). 6. Control the speed of traverse by using the traversespeed control knob ("L" models only) (figure 28, ItemC). 7. To stop, release the forward/reverse switch. 8. To reverse the machine, push in the white reverseswitch (figure 28 item B) and either the right or leftforward/reverse switch (figure 28 item A) at the sametime ("L" models only). 9. To stop, release the forward/reverse switch. 10. To turn the machine, push the rear of the machine tothe side. 11. When you stop the machine, press the red "OFF" button or turn the key switch counterclockwise to the"OFF" position ("L" models only). Remove the keyand set the parking brake (if equipped). B How To Operate The Machine A C A Figure 28 How To Clean A Floor WARNING: Water solutions or cleaningmaterials used with this type ofmachine can leave wet areas on the floor surfaces. These areas can cause a dangerous condition for theoperator or other persons. Alwaysput CAUTION signs near the area youare cleaning. To clean a floor follow this procedure: 1. Set the parking brake (if equipped with machine.) 2. Put the water and a cleaning chemical in the cleansolution tank. 3. Release the parking brake (if equipped with machine.) 4. Turn the key switch clockwise to the "ON" position ("L" models only). Press the green "ON" button. 5. Lower the squeegee. 6. Press the brush down button until yellow light isilluminated and the correct pressure is achieved. WARNING: This machine is capable ofmaximum head pressure with wornpads or brushes. With this feature, there is the possibility of exceedingthe recommended brush pressure onnew pads or brushes. This will either create re-occurring circuitbreaker tripping or the possibility oflost traction and control. The brush switch should be activated to accomplish only enough brushpressure for the job. This will allow longer battery life and cleaningtime. NOTE: Keep the machine moving when the brush isrotating on the floor. Pre-wet brush/pad or keep lightpressure on brush until solution flow is adequate tokeep brush/pad from scratching the floor. Clarke® Operator's Manual -FOCUS S17/L17 and S20/L20 Page -19 EN How To Operate The Machine EN How To Operate The Machine To pre-wet brushes you should first turn the speed knob tothe lowest traverse setting on the "L" model. Then on both the "S" and "L" models, lower brushes until brushes are just touching the floor and the yellow light on the controlpanel in illuminated. Activate the forward/reverse switch tostart motor and solution flow. NOTE: On the "L" model, the machine will not move when the traverse speed knob is rotated fully counterclockwise. 7. Adjust the flow of clean solution to the flow desired. 8. Move the machine across the floor in the forward direction. 9. Make a 180° turn. NOTE: When you make more passes across the floor, letthe brush clean approximately 2 inches (5 cm) of the areaalready cleaned by the brush. NOTE: During most cleaning procedures, apply andremove the solution in one operation. How To Clean A Very Dirty Floor To clean a very dirty floor, follow this procedure: 1. Apply solution to the floor. 2. Do not lower the squeegee. This will keep the vacuummotor off. 3. Lower the brush or pad and scrub the floor. 4. Scrub the floor again with additional solution and lowerthe squeegee. 5. Pick up all the solution with the squeegee. Maintenance WARNING: Maintenance and repairs must be done byauthorized personnel only. WARNING: Always empty the solution tank and recovery tank before doing any maintenance. WARNING: Keep all fasteners tight. These Maintenance Procedures Must Be Done Every Day Keep the machine clean, it will need fewer repairs and have longer life. Do These Procedures When You Begin Your Work Period 1. Disconnect AC power from battery charger (follow charger instructions). 2. Store AC power cord to charger in machine storage compartment (See Figure 29). 3. Make sure the screen filter is installed properly in the recovery lid and is clean (See figure 30). 4. Make sure the recovery tank lid is on correctly (See Figure 30). Figure 29 Figure 30 Page -20- Clarke® Operator's Manual -FOCUS S17/L17 and S20/L20 EN EN Maintenance 5. Make sure the valve on the recovery drain hose isclean. Tightly close the valve. 6. Make sure the brush/pad is in position andinstalled correctly. 7. Make sure brush housing and skirts are inposition on the brush head. 8. Check the installation of the squeegee andsqueegee hose. 9. Make sure the solution drain / level indicator hoseis secure on the storage mount on the rear of themachine. Do These Procedures When You End Your Work 1. Drain the solution tank (Figure 31) and the recovery...

Este manual também é adequado para os modelos :
Aspiradores - FOCUS L17 (1.21 mb)
Aspiradores - FOCUS S17 (1.21 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias