Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Nilfisk-ALTO, Modelo SCRUBTEC 770 S 05211F

Fabricante : Nilfisk-ALTO
Arquivo Tamanho: 3.15 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


8. Put the traverse speed switch to the mid range speed setting. As the machine begins to travel down the ramp, maintain a slow downward speed by pressing either of the forward switches. 9. Replace squeegee assembly, brush housings, & brushes or pad drivers after the machine is unloaded and ready to use. Nilfi sk ALTO Operator's Manual -SCRUBTEC 770 / 784 / 795 FORM NO. 70935A - 7 SYMBOLS USED ON SCRUBTEC 770, 784, 795 SYMBOLS USED ON SCRUBTEC 770S, 784S, 795S / 770L, 784L, 795L Hazard Alert Symbol On/Off Key Switch Power Traverse Speed Control SYMBOLS USED ON SCRUBTEC 770S, 784S, 795S SYMBOLS USED ON SCRUBTEC 770L, 784L, 795L Additional Brush Pressure Brush Up/Down Squeegee Up/Down Solution Control Hour Meter Switch Brush Up/Down Solution Control Charge/Battery Meter (Solo) Charge Indicator One Touch Switch Charge Indicator (I-Drive) -8-FORM NO. 70935A Nilfi sk ALTO Operator's Manual -SCRUBTEC 770 / 784 / 795 SYMBOLS USED ON SCRUBTEC 770, 784, 795 71018A WARNING READ OPERATOR'S MANUAL BEFORE OPERATING THIS MACHINE RISK OF FIRE • Use only commercially available floor cleaners and waxes intended for machine operation. • Do not use flammable materials. RISK OF INJURY OR DAMAGE TO MACHINE • Do not turn, stop or leave machine on a ramp or dock. 71015A WARNING READ OPERATOR'S MANUAL BEFORE OPERATING THIS MACHINE EXPLOSIVE GASES, CAN CAUSE SEVERE INJURY, DEATH OR DAMAGE TRANSFORMER. • Keep flammable materials away from batteries. Charge in a cool well ventilated BATTERIES CONTAIN SULFURIC ACID. CAN CAUSE SEVERE INJURY. • Avoid contact with skin eyes, or clothing. If contact, flush with water. Get medical attention. If internal. contact call physician. WEAR PROTECTIVE EYE GEAR. 71017A WARNING MOVING PARTS. CONTACT CAN CAUSE SEVERE INJURY. • Do not place hands or feet under machine when in use. 71014A WARNING FALLING PARTS CAN CAUSE SEVERE INJURY. • Make sure tank is secure before servicing. Nilfi sk ALTO Operator's Manual -SCRUBTEC 770 / 784 / 795 FORM NO. 70935A - 9 MACHINE CONTROL PANEL 770S, 784S & 795S Key Switch (See Figure #1, Item “A”) The key switch turns “ON” the power to the control panel. “0” is “OFF” and “I” is “ON”. Traverse Speed Switch (See Figure #1, Item “B”) The speed control varies from low to high speed. To increase the speed, turn the knob to the right. To decrease the speed, turn the knob to the left. Brush Up/Down Switch (See Figure #1, Item “C”) The brush switch has two positions: “Up” positions the brushes up; “Down” positions the brushes on the floor. The brush motors start when the brushes are down and the traverse switch is depressed. Increase Brush Pressure Switch (See Figure #1, Item D) This switch is used to increase the brush pressure. Increased brush pressure may be required when stripping or cleaning heavily soiled floors. To increase brush pressure, first lower the brushes by pressing the brush up/down switch (Item “C”) to the down position. This will lower the brushes to the normal scrub position. To increase brush pressure, press and hold the switch (Item “D”) until the desired brush pressure is reached or the brush deck stops moving downward. To reposition the brush pressure to normal scrub, press the brush up/down switch (Item “C”) to the up position and after the brush deck is completely raised, then return the switch to the down position for normal scrub. Solution Control Knob (See Figure #1, Item “E”) The solution control knob regulates the flow of cleaning solution to the floor. To increase the flow turn the knob clockwise. To decrease the flow, turn the knob counter-clockwise. Forward Switch (See Figure #1, Item “F”) The forward switch turns the traverse motor “on” and if the brush motors are in the down position, it also activates the brush motors and solution control module. Either the right or the left switch can be used. Reverse Switch (See Figure #1, Item “G”) The reverse switch, when used in conjunction with one of the forward switches, causes the machine to reverse direction. The reverse speed is 70% of the forward speed. Charge / Battery Meter (Solo) (See Figure #1, Item “H1”) The charge/battery meter indicates the battery is being charged when the charger is plugged into an AC outlet. It also indicates the amount of charge that is left in the batteries while the machine is in use. When the battery charger gets too low the red light will begin flashing and the brush/pad motors will shut off. Battery Meter / Charge Indicator Light (I-Drive) (See Figure #1, Item “H2”) The battery meter indicates the amount of charge remaining in the batteries while the machine is in use. When the charger is plugged into an AC Outlet, the charge green indicator light will flash on and off. When the batteries become fully charged, the green indicator light will remain on until the charger is unplugged. Circuit Breakers (See Figure #1, Item “I”-”M”) The circuit breaker reset buttons are located on the control panel. The breakers are located as follows: Item I & J - Brush Motors (35A);...

Este manual também é adequado para os modelos :
Aspiradores - SCRUBTEC 770 S 05210F (3.15 mb)
Aspiradores - SCRUBTEC 770 S 05210G (3.15 mb)
Aspiradores - SCRUBTEC 770 S 05220F (3.15 mb)
Aspiradores - SCRUBTEC 770 S 05220G (3.15 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias