|
por este dispositivo também tem outras instruções :
Facilidade de uso
1 Unplug the Cleaner from electrical outlet. 2 The Dirt cup can be reached by removing the Dirt cup, reaching underneath the Upper Tank and turning the rim of the Filter Frame to unlock. Pull straight down to remove. Brush the dirt off the Louvers and Dirt cup. 3 The foam Upper Tank Filter may be removed and hand washed in cold water with mild detergent. Rinse well then air dry throughly before replacing. Dirt-Cup check or Filter clogged Indicator Cleaning the Dirt cup 1 Unplug the Cleaner from electrical outlet. 2 The Cartridge Filter Tank assembly can be reached by pulling it from the cleaner. 3 Remove the cover from the Cartridge Filter Tank, and the foam may be removed and hand-washed in cold water with mild detergent, then air dried. 4 Reposition Filters when completely dry. 1 Unplug the Cleaner from electrical outlet. 2 The HEPA Media Post-Motor Filter assists in the filtration process to return clean air to the room. It is located behind the door on the side of the cleaner. If the filter becomes dirty, open the door, remove the filter and clean. To remove this filter, open the door on the side of the cleaner, grasp filter and pull it straight out. 3 Reposition the HEPA Media Post-Motor Filter, then lock the door. Cleaning the Cartridge Filter Tank Cleaning the HEPA Media Post-Motor Filter WARNING: Do not operate cleaner with damp or wet filters or without all filters in place. WARNING: To reduce the risk of injury from moving parts, turn off vacuum cleaner and disconnect Power Plug from electrical outlet. Cartridge Filter Tank HEPA Media Post-Motor Filter Maintenance 10 Check Rotating Floor Brush and Drive Belt Replace Drive Belt You should check your vacuum cleaner’s Rotating Floor Brush and Drive Belt regularly for wear or damage. You should also clean the brush and brush ends of strings, hair, and carpet fibers. These can wrap around the brush and hamper its ability to effectively clean your carpet. Also remove any debris that has accumulated under the brush cover. 1 Unplug cleaner from electrical outlet. 2 Place handle in Low position. 3 Remove the four screws as shown with a screwdriver. 4 Turn over the cleaner. 5 Remove the eight screws, and turn over the cleaner again. 6 Lift the cover-Brush off. 7 Remove the three screws on the case-drum. 8 Grasp Rotating Floor Brush at both ends and lift. 9 Clean strings, hair and other debris from Rotating Floor Brush, paying particular attention to brush ends. 10Clean strings, hair and other debris from Motor Pulley and Drive Belt areas. 11Check Drive Belt carefully for wear, cuts or stressed areas. 12Check Air Passageway for obstructions. Remove debris from this area. 1 Unplug cleaner from electrical outlet. 2 With Rotating Floor Brush removed from vacuum cleaner(Step1-7 of Check Rotating Floor and Drive Belt) grasp old Drive Belt and remove from Motor pully. Discard old Drive Belt. 3 Place new Drive Belt over motor pulley and stretch other end over rotating Floor Brush in the space between the bristles. 4 Place ends of rotating Floor Brush down into slots on sides as shown. 5 Turn rotating Floor Brush by hand several times in direction of motor pulley, if properly installed, Drive Belt will center itself. 6 Reposition Brush cover and eight screws. Tighten screws securely. Snap end of Brush cover into place. Maintenance 11 Clearing Clogs Low suction or poor pickup may be due to a clog in the vacuum cleaner. If you notice a change in the sound of the motor or a reduction in the spinning action, check for clogs. 1 Unplug cleaner from electrical outlet. 2 Empty Dirt Cup. 3 Check Case filter for build up or clogs. 4Remove the Case filter and check the suction inlet for a clog. 5 Grasp the Quick Reach Handle and lift Hose Wand to separate from the suction opening. Check for a clog in the Base, the Wand or the Hose. 6 Remove the screw attaching the Hose Wand Base to the vacuum. Straighten the Hose Wand Base and unclog with long, narrow object. 7 Turn the vacuum cleaner off and unplug it. Remove the brush cover, check the air passageway for obstructions. Remove debris from this area. Reposition brush cover and eight screws. Tighten screws securely, snap end of brush cover into place. Maintenance *Brushbar Replacement *Belt replacement 1 Remove the tool from the hose, and turn upside down. Slide the switch to unlock position and remove bottom plate. 2 Unscrew the one screw and remove belt guard. 3 Remove brushbar including end plates and discard. 4 Inspect belt to ensure that it is in good condition. If broken or cracked, please replace. (See below for details.) 5 With the curved ends facing down, slide end plates of brushbar into slots on the tool. 6 To replace bottom plate, insert the four tabs on edge of bottom plate into slots on front of tool. Pivot bottom plate down and snap closed. 1 Grasp turbine and pull firmly to remove. 2 Remove a screw, and lift the cover belt off. 3 Remove belt from turbine pulley. Replace with new belt. 4 With flat sides of turbine ...
Este manual também é adequado para os modelos :Aspiradores - SU8550 (2.15 mb)
Aspiradores - SU8551 (2.15 mb)