Log:
Assessments - , GPA: ( )

Instruções de Operação Campbell Hausfeld, Modelo Benchtop Blast Cabinet MXS3000

Fabricante : Campbell Hausfeld
Arquivo Tamanho: 541.15 kb
Arquivo Nome : 2db8f644-0398-482c-98c4-321f66194548.pdf

Língua de Ensino: enesfr

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


Place and securely tighten a small hose clamp around section of hose covering barb. • Press end of MATERIAL hose fully onto tool material inlet flange. Place and securely tighten a medium hose clamp around section of hose covering flange. • Press other end of MATERIAL hose about 1 in. - 2 in. onto the small diameter end of the metal diptube. Place and securely tighten a medium hose clamp around section of hose covering diptube. • Place gun and hose assemblies into cabinet, feeding diptube under the wire mesh parts tray. Place a washer on threaded end of cabinet inlet fitting, then push fitting through the hole on the lower right side of cabinet. Place other washer on the protruding end of the fitting (see Figure 2). • Apply teflon tape to the threads of the inlet fitting to reduce the possibility of air leaks. Thread the female fitting onto the protruding threads of the cabinet inlet fitting and tighten securely. Make sure the wrench flats of the female fitting abut the cabinet (see Figure 2). D DDo ooo oor rr l lla aat ttc cch hhe ees ss • Place black plastic door latches over the holes on the edges of the cabinet top. Secure each to cabinet top using a 1 in. long bolt and a lock nut. Tighten firmly, but do not overtighten. C CCa aab bbi iin nne eet tt f ffi iil llt tte eer rr • Place round filter sponge in cabinet filter housing. Place filter housing over large hole in rear of cabinet, lining up the holes on the edge of the housing with the posts above and below the cabinet hole. Twist and lock. Figure 2 - Air Inlet assembly Air Hose Clamp Air Inlet Washers Female fitting Male plug 2 MXS3000 Assembly (cont.) L LLa aam mmp pp • Make sure the power supply is not plugged into lamp switch outlet. Place lamp switch box up to free end of lamp cord. Connect flag terminals from the lamp cord to the lamp switch terminals labeled “2” together. The brown wire goes on the top (near the “2”), the blue wire goes directly beneath. Secure lamp switch box to the cabinet using two (2) 5/16 in. long bolts, nuts, and lock washers. Tighten securely. Operation After the blast cabinet is completely assembled, follow these instructions before supplying air to the cabinet. 1. Position cabinet on a table or workbench where you will be performing the work. 2. Connect air supply (max. 125 psi) to the fitting on the side of the cabinet (see Figure 3). Figure 3 – Connect air supply Air hose and connection Air supply fitting 3. Check for air leaks. If any are found, repair or add teflon tape if needed. 4. Plug the 12V power supply into a 110V wall outlet (see Figure 4). 5. Making sure the switch is in the (O) OFF position, plug the other end of the 12V power supply cord into the light switch on the cabinet (see Figure 4). 6. Check that the light works. It can be rotated to prevent the light from shining directly into your eyes. 7. Add a plastic window protector (supplied) to the inside surface of the glass door. Figure 5 – Material hose and metal pick-up tube Small tube Larger tube 9.Position the end of the pick up tube in the middle of the cabinet where the blast media will be deepest. There are metal guides to help stabilize the pick-up tube (see Figure 6). Figure 6 – Pick-up tube and guides Guides Figure 4 – Light switch power supply 1. Plug power supply cord into wall outlet 8. Make sure the material hose is securely attached to the smaller tube (and does not touch the larger tube) of the metal pick up (see Figure 5). 3.Plug other end of power supply cord into back of switch box 2.Make sure switch is in the (O) OFF position 10. Put on a NIOSH/MSHA approved respirator and eye protection. 11. Pour blast media into cabinet basin. Make sure the end material hose is completely covered. You can create dust when abrasive media is poured into or drained from the blast cabinet. Wear a mask and eye protection when draining the blasting media. 12. Place item to be cleaned inside cabinet. 13. Close and latch door. 14. If a vacuum is to be used to remove blast media dust: A.Remove air filter from back of cabinet (this filter is for use when a vacuum is NOT used) B. Install a proper sized adapter on end of vacuum hose and insert into port on right hand side of cabinet. If the right size adapter is not available, any sort of attachment method that provides decent seal will work. 15. Place hands in gloves, aim blast gun at surface to be cleaned and pull trigger. 3 Operating Instructions Operation (cont.) 16. A common wire screen placed on cabinet grating can help to prevent small items from getting lost in hopper. Maintenance Cleaning The plastic door cover should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic parts. They could dissolve or otherwise damage the material. Changing the Ceramic Gun Nozzle The blast cabinet is equipped with a ceramic nozzle that controls the flow of abrasive media as it exits the spray gun. The nozzle creates a smaller opening for the media to exit which giv...

Este manual também é adequado para os modelos :
Aspiradores - Benchtop Blast Cabinet MXS3000 (541.15 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias