Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação DeVilbiss, Modelo SB-E2-2-531

Fabricante : DeVilbiss
Arquivo Tamanho: 969.22 kb
Arquivo Nome : COMPACT_CONV_P_UserManual.pdf
Língua de Ensino: enfrde
Ir para baixar



Facilidade de uso


If there is any doubt regarding the suitability of a specific material contact your local Distributor or ITW Finishing direct. Model Part Number Example: COM-P430-14 Aircap Fluid nozzle size (14 = 1,4 mm) EC Declaration of ConformityWe: ITW Finishing UK, Ringwood Rd, Bournemouth, Dorset, BH11 9LH, UK, as the manufacturer of the Spraygun model Compact, declare, under our sole responsibility, that the equipment to which this document relates is in conformity with the following standards or other normative documents: BS EN 292-1 PARTS 1 & 2: 1991, BS EN 1953: 1999; and thereby conform to the protection requirements of Council Directive 98/37/EC relating to Machinery Safety Directive, and; EN 13463-1:2001, council Directive 94/9/EC relating to Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres protection level II 2 G X. B. Holt, General Manager 30th June 2003 ITW Finishing Systems and Products reserve the right to modify equipment specification without prior notice. © 2003 ITW Finishing Systems and Products 2 SAFETY WARNINGS E EE Fire and explosion Always wear eye protection when Solvents and coating materials spraying or cleaning the spraygun can be highly flammable or combustible when sprayed. ALWAYS Gloves must be worn when spraying or cleaning the refer to the coating material suppliers equipment instructions and COSHH sheets before using this equipment Training – Personnel should be given Users must comply with all local adequate training in the safe use of and national codes of practice spraying equipment. and insurance company Misuse requirements governing ventilation, fire precautions, operation Never aim a spraygun at any part of the and house-keeping of working areas body Never exceed the max. recommended This equipment, as supplied, safe working pressure for the equipment is NOT suitable for use with Halogenated Hydrocarbons. The fitting of non-recommended or non- Static Electricity can be original spares may create hazards generated by fluid and/or air Before cleaning or maintenance, all passing through hoses, by the pressure must be isolated and relieved spraying process and by cleaning non- from the equipment conductive parts with cloths. To prevent The product should be cleaned using a ignition sources from static discharges, gun washing machine. However, this earth continuity must be maintained to equipment should not be left inside gun the spraygun and other metallic washing machines for prolonged periods equipment used. It is essential to use of time. conductive air and/or fluid hoses. Noise Levels Personal Protective The A-weighted sound level of Equipment sprayguns may exceed 85 dB Toxic vapours – When sprayed, (A) depending on the set-up certain materials may be being used. Details of actual noise levels poisonous, create irritation or be are available on request. It is otherwise harmful to health. recommended that ear protection is worn Always read all labels and safety data at all times when spraying. sheets for the material before spraying and follow any recommendations. If In Operating Doubt, Contact Your Material Supplier Spray Equipment using high pressures The use of respiratory protective may be subject to recoil forces. Under equipment is recommended at all certain circumstances, such forces could times. The type of equipment result in repetitive strain injury to the must be compatible with the material operator. being sprayed. 3 © 2003 ITW Finishing Systems and Products E EE Parts List Ref. No Description Part Number Qty Options 1 Air Cap/Retaining ring COM-430 or COM-497 SP-100-***-K 1 430, 497 e.g *** = 430 + 2 Nozzle SP-200S-**-K 1 085,10,11,12,13,14, 16,18,20,22 e.g ** =14 =1.4mm + 3 Separator SP-623-K5 5 + 4 Packing GTI-445-K2 2 5 Spreader Valve SP-401-K 1 6 Stud and Screw GTI-408-K5 5 7 Needle Adjusting Screw SP-614-K 1 + 8 Spring SP-622-K5 1 + 9 Needle SP-300S-**-K 1 085,10,11,12,13,14, 16,18,20,22 e.g ** =14 =1.4mm Needle—Plastic tipped SP-300P-**-K 10, 12, 14 e.g ** =14 =1.4mm 10 Airvalve housing + seal SP-612-K 1 + 11 Spindle 1 12 Trigger SP-617-K 1 13 Connector SP-611-K 1 14 Airflow Valve SP-402-K 1 15 Fluid Inlet Connector and seal SP-610–K 1 + 16 Air Valve Service Kit SPK-101-K 1 17 RetainingRing and Seals SPK-102-K 1 + 18 Spreader/ Cheater Service Kit GTI-428-K5 5 19 Circlip 25746-007-K5 5 + 20 Air valve Assembly Tool 1 21 Spanner SPN-5 1 Spraygun Service Kit (parts included marked + ) SPK-401-** 1 085,10,11,12,13,14, 16,18,20,22 e.g ** =14 =1.4mm © 2003 ITW Finishing Systems and Products 4 Specification EEPatent No 2372465 (GB) Specification EEPatent No 2372465 (GB) Air supply connection -Universal 1/4“ BSP and NPS Fluid Supply Connection -Universal 3/8“ BSP and NPS Maximum static Air inlet pressure -P1 = 12 bar (175 psi) Maximum static Fluid inlet pressure -P2 = 15 bar (218 psi) Nominal gun Air inlet pressure -3.0 bar (44 psi) with gun triggered Maximum Service temperature 40°C Gun Weight -435 g Materials of Construction Gun body...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias