Log:
Assessments - 4, GPA: 4.8 ( )

Instruções de Operação Earlex, Modelo HV7000P

Fabricante : Earlex
Arquivo Tamanho: 581.7 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The round spray is used for small objects or for areas - such as corners – that are difficult to reach. To adjust the spray pattern, loosen the Air Cap Ring (1), adjust the position of the Air Cap (2) to obtain either a vertical, horizontal or round pattern then re-tighten the aircap ring. PAINT VOLUME The volume of paint sprayed is easily adjustable. (Fig.5(a)) Completely close Fluid Adjusting Screw (8) by turning this clockwise as far as it will go. Whilst pulling the trigger, begin turning the adjustment screw counter-clockwise until the volume of paint you require is obtained. If the paint spray is too wide or contains too much paint turn the Fluid Adjusting Screw clockwise again. Once the correct spray pattern & paint volume is obtained, you are ready to begin spraying. Fig.5(b) shows the Air Volume Control Valve set for ‘FULL’ air flow. Rotate clockwise to reduce air flow. SPRAYING SPRAYING TECHNIQUE 1. To obtain the best results always keep your spray applicator level and spray equally from side to side or up or down 10”-12” (25-30cm) from the surface. Avoid spraying at an angle as this will lead to runs on the surface (Fig.6a). Fig.5 2. Let your arm control the left to right movement rather than your wrist as this will aid even paint distribution over the whole area (Fig.6b). 3. Do not tip the sprayer to more than 45°angle (Fig.6c). Fig.6a Fig.6b Fig.6c HELPFUL HINTS 1. Evenly control the speed of movement of the spray applicator. A fast speed will give a thin coat and a slow speed will give a thick coat. 2. Only apply one coat at a time. If a further coat is required follow the paint manufacturer’s instructions for drying times. 3. If spraying small areas or objects keep the output setting low as this will avoid excessive use of paints and will minimise overspray. 4. When spraying large areas or objects, it is best to use a criss-cross pattern, either from left to right then up or down or vice-versa. This will ensure maximum coverage (Fig.7). 5. Avoid stopping and starting when spraying as this can lead to too much or not enough material on a surface. 6. To ensure edges are covered, commence spraying just to the side of area being sprayed. 7. CLEAN SPRAYER AFTER EVERY USE (SEE CLEANING INSTRUCTIONS) 5 Let go of the trigger at the end of each spray movement to avoid excessive paint and drips Fig.7 N0150 05/05.qxd 27/5/05 10:28 am Page 6 CLEANING INSTRUCTIONS Remember to disconnect the unit from the mains power when undertaking any cleaning of the Spray Port. THE SPRAY APPLICATOR MUST BE THOROUGHLY CLEANED IMMEDIATELY AFTER USE. IF THE PAINT DRIES INSIDE THE GUN, CLEANING WILL BECOME MUCH MORE DIFFICULT AND MAY RENDER THE GUN INOPERABLE. THIS IS NOT COVERED BY WARRANTY. The spray applicator is the same as a paintbrush, if it is not cleaned it will go hard and can become useless. You must therefore clean this out after use. SPRAY APPLICATOR 1. Remove the gun container. 4. Clean any traces of paint off the outside of the spray applicator. 2. Pour any leftover paint into its container so that it can be used for the future. 5. Clean the container Seal inside the spray applicator body for Type P or inside the spray 3. Pour a quantity of the respective thinner into applicator body for Type A. container, shake the spray applicator lightly, reassemble the gun, then spray this liquid through the gun. Repeat this until the thinner being sprayed is coming through with no traces of paint. FLUID TIP & NEEDLE (Type P) 8. Remove Fluid Tip Seal (5) 9. Remove Paint Container Seal (12) 1. Unscrew Air Cap Ring (1) 10. Place all of these items into a container and clean 2. Remove the Air Cap (2) them using a brush and clean thinners 3. Completely remove Fluid Adjusting Screw (8) 11. Clean the inside of the body of the gun 4. Remove the Spring (7) 12. Thoroughly dry these parts before reassembling 5. Remove the Fluid Tip Needle (6) by gently pulling 13. Grease the Gland (10) the trigger 14. Reassemble parts in reverse order 6. Remove Direction Plate noting the position of notches (3) 7. Remove the Fluid Tip (4) It is recommended fitting the Fluid Tip (4) prior to the needle FLUID TIP & NEEDLE (Type A) 1. Remove the Air Cap Ring (1) 6. Immerse all of the parts above in thinners & clean 2. Remove the Air Cap (2) them thoroughly using the cleaning kit supplied 3. Remove Direction Plate & Spring Assembly (3) with the gun. 4. Unscrew Adjusting Screw (12) & pull out the 7. Before refitting the Needle, dip its end into some Needle (9) & Needle Spring (11). vasaline. This will automatically lubricate the 5. Use the spanner supplied to remove the Fluid Tip gland washer as it is inserted. (4) & Fluid Tip Seal (5) 8. The external surfaces of the spray applicator can be wiped clean with a cloth soaked in thinners. NEVER DISPOSE OF PAINTS OR SOLVENTS INTO DRAINS. CONTACT YOUR LOCAL COUNCIL TO ARRANGE COLLECTION OR FOR DETAILS OF NEAREST REGISTERED DISPOSAL SITE. TURBINE UNIT AND CARRIER STAND . The Turbine unit and the Carrier and St...

Este manual também é adequado para os modelos :
Armas - HV7000A (581.7 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias