Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Healthyway, Modelo 310645H

Fabricante : Healthyway
Arquivo Tamanho: 2.02 mb
Arquivo Nome : 50efd788-d8af-40ae-8d8b-7e89e17a29bb.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Box 1441 Minneapolis, MN 55440-1441 Copyright 2004 Graco Inc. is registered to I.S. EN ISO 9001 310645H Repair and Parts RTX 1500 Electric Texture Sprayer - For Water-Based Materials Only - (Consult your Material Supplier for Warnings and Application Requirements) Models: Page 2 Maximum Working Air Pressure: 45 psi (3.1 bar) Maximum Working Fluid Pressure: 100 psi (6.9 bar) Read all warnings and instructions. CAUTION Use RTX 1500 non-bleeder texture gun 248091. All other guns will damage sprayer. ti4305a Models Models Model Electric Requirements Country Manual Languages Operation 287328* Gun 248201 120V, 60 Hz, 15 A N. America 310624 310694 310616 English 248370 / 248315 230V. 50 Hz, 10 A Europe 310624 310616 French 248370 230V. 50 Hz, 10 A Europe 310624 Dutch 248370 230V. 50 Hz, 10 A Europe 310625 310616 Spanish 248370 / 248315 230V. 50 Hz, 10 A Europe 310625 Italian 248370 230V. 50 Hz, 10 A Europe 310625 Portuguese 248370 / 248315 230V. 50 Hz, 10 A Europe 310625 German 248315 230V. 50 Hz, 10 A Europe 310697 Swiss 248315 230V. 50 Hz, 10 A Europe 310697 Danish 248370 230V. 50 Hz, 10 A Europe 310697 Norwegian 248370 230V. 50 Hz, 10 A Europe 310697 Swedish 248370 230V. 50 Hz, 10 A Europe 310698 Polish 248370 230V. 50 Hz, 10 A Europe 310698 Russian 248370 230V. 50 Hz, 10 A Europe 310698 Greek 248315 230V. 50 Hz, 10 A Asia 310699 Chinese 248315 230V. 50 Hz, 10 A Asia 310699 Japanese 248315 230V. 50 Hz, 10 A Asia 310699 Korean 248315 230V. 50 Hz, 10 A Australia 310699 310694 310616 English *Auxiliary Air Hookup Kit RELATED MANUALS Model Country Manual Languages ALL ALL 310645 English 310645H Warnings The following are general Warnings related to the safe setup, use, maintenance and repair of this equipment. Additional, more specific warnings may be found throughout the text of this manual where applicable. Warning WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution CAUTION Alerts you to the possibility of damage or destruction of equipment if you do not follow the instructions. Warnings Fire and Explosion Hazard Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Keep work area free of debris, including solvent, rags, and gasoline. • Ground equipment in the work area. See Grounding instructions. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. Equipment Misuse Hazard Equipment misuse can cause death or serious injury. • Do not exceed maximum working pressure or temperature rating of lowest rated system component. See Technical Data, in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. • Check equipment daily. Repair or replace worn or damaged parts immediately. • Do not alter or modify this equipment. • Use the equipment only for its intended purpose. Call your Graco distributor for information. • For professional use only. • Route hoses away from traffic areas, sharp edges, moving parts and hot surfaces. • Do not use hoses to pull equipment.‘ • Keep children and animals away from work area. • Comply with all applicable safety regulations. Electric Shock Hazard Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power cord before servicing equipment. • Use only grounded electrical outlets. • Use only 3-wire extension cords. • Ensure ground prongs are intact on sprayer and extension cords. 310645H Warnings WARNINGS Pressurized Equipment Hazard Compressed air can inject in skin. Air tubing rupture can cause injury if disconnected while under pressure. To reduce risk of injury: • Never exceed maximum working pressure of any attachment. • Do not direct airstream at body. • Follow Pressure Relief Procedure, page 7 whenever you are instructed to relieve pressure, stop spraying, service equipment, install or clean spray nozzle or disconnect or connect hose. Cleaning Solvent Hazard with Plastic Parts Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. Many solvents can degrade plastic parts to the point where they could fail. Such failure could cause serious injury or property damage. See Technical Data on page 34 of this instruction manual and in all other equipment manuals. Read fluid and solvent manufacturer’s warnings. Moving Parts Hazard Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply. Personal...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias