Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Omega, Modelo LDP-146

Fabricante : Omega
Arquivo Tamanho: 198.03 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


12.- MECHANICAL DIMENSIONS mm (inches) Aluminium back plate C PANEL CUT-OUT B E D Panel thickness : Max. 14 (0.55) Min. 2.5 (0.10) A Anti-Glare red lens Table 5 DIMENSIONS PANEL CUT-OUT WEIGHT POWER Digits Height A B C D E 4 57 (2.3) 264 (10.4) 120 (4.75) 112 (4.41) 256 (10.07) 112 (4.4) 2.3 Kg (5 lbs) 6 VA 4 100 (4) 480 (18.9) 180 (7.09) 112 (4.41) 472 (18.58) 172 (6.77) 5 Kg (11 lbs) 12 VA 6 57 (2.3) 384 (15.12) 120 (4.75) 112 (4.41) 376 (14.8) 112 (4.4) 2.7 Kg (6 lbs) 6 VA 6 100 (4) 688 (27.1) 180 (7.09) 112 (4.41) 680 (26.77) 172 (6.77) 5.7 Kg (12.5 lbs) 12 VA Dimensions in mm. Parenthesis are in inches or pounds. Add 27 mm to the dimension C for power connector. Page : 13 APPENDIX 1: MODEL LDP-1XX-CX AS SLAVE REPEATER. FUNCTIONAL DESCRIPTION: Special configuration of Models LDP-1XX-CX for serial RS-422 repeater, to be used as slaves. The Serial port connection which is the only that keeps in operation, it is used to enter the data coming from the Master. The rest of functions and connections of these Models, remain disabled. CONFIGURATION OF A SLAVE MODEL, STARTING FROM A MASTER MODEL LDP-1XX-CX: -Remove the integrated circuit "IC4" placed on the PCB "98/04" and close jumper JPA2. CONFIGURATION OPTIONS: Jumper JP1 placed on PCB "98/06", connects the RS-422 line termination (220 Ohm.). The rest of the Mini-dips and Jumpers are disabled on this Mode. JP1 JPA2 TS1137A JPA3 JPA4 REMOVE IC4 SITUATION JUMPER JPA2 JP1 Configuration Diagram. Charge connected Charge disconnected C.I.98/04 C.I.98/06 OPERATION: After powered up the unit, the 4 digit Models will display "SLU" and the 6 digit Models will display "SLAUE". These above indications will remain on the Display, until to receive valid data through RS-422 channel. Page : 14 APPENDIX 2: TIME-NET CONFIGURATION AND CONNECTIONS. It is advisable to make the TIME-NET connections as follows: MASTER SLAVESLAVE SLAVE SLAVE SLAVE 1 432 Transmitter Unit Receiver Units Connect RS-422 (JP1) line termination. n (maximum 32 units) Don’t connect RS-422 (JP1) line termination. Note Shielded twisted-pair cable, must be used for connections. MASTER SLAVE 9 1 5 6 9 5 6 shield shield To other slaves To other slaves Don’t connect the cable shield to the receiver units (slaves). 1 COMPATIBILITY TABLE AMONG MASTER-SLAVE master slave 124-C0 124-C1 126-C2 144-C0 144-C1 146-C2 LDP-124-C YES NO YES NO LDP-126-C NO YES NO YES LDP-144-C YES NO YES NO LDP-146-C NO YES NO YES Page : 15 WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear ins...

Este manual também é adequado para os modelos :
Gravadores Tempo - LDP-124 (198.03 kb)
Gravadores Tempo - LDP-126 (198.03 kb)
Gravadores Tempo - LDP-144 (198.03 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias