Log:
Assessments - 1, GPA: 3 ( )

Instruções de Operação Altinex, Modelo MT108-102

Fabricante : Altinex
Arquivo Tamanho: 204.27 kb
Arquivo Nome : 17ef0ce8-9e97-427a-ab2d-b46eba32b7df.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Command Format: [VERCnUi] Cn = card ID number (n = # from 1 to 19) 6 MULTI-TASKER Ui = Unit ID (i = # from 0 to 9) (refer to the MT100-100 user’s guide for explanation) Example: If one MT108-103 card is plugged in slot #2 of unit 3: Sending the command [VERC2U3], will yield the following feedback from the Multi-Tasker™ MT108-103 690-0127-007 MT108-103 = card type 690-0127-007 = software version 2. [C] This command receives the status of the card. Command Format: [CnUi] Cn = card id (n = from 1 to 19) Ui = unit id (i = from 0 to 9) (refer to the MT100-100 user’s guide for explanation) Example: If one MT108-103 card is plugged into slot #2 of unit 3 with outputs 1 and 2 ON, sending the command [C2U3] will yield the following feedback: ON: 1,2 C02 If there is no card plugged in slot #2 of unit 3, the Multi-Tasker™ will not return any feedback. 3. [CiS] This command saves the current status of the card's output enable configuration. This configuration will be restored after system is reset or powered off then on. Ci = card number S = save configuration If Inputs 1,2,3 and 4 are enabled, the feedback after sending the command [C4S], for slot 4, would be: ON:1,2,3,4 C04 Saved 4. [SIG] The Signal Present command tests for the presence of a signal on the input. After sending the command, the feedback will be either "1" signifying a signal is present, or a "0" indicating no signal was detected. Command Format: [SIGCnUi] Cn = card number Ui = unit ID Example: To check for the presence of an input signal on card 4, send the command [SIGC4] and verify feedback of "1" or "0". 5. [ON] This command enables one or more outputs of a single card or a group of cards. [ONmCnUi]: for a single card This command enables output “m” without affecting any other outputs. m = Output number (m = 1 to 4) n = Card ID number (n = 1 to 19) i = Unit ID number (i = 0 to 9) Example: 1) [ON12C5U3]: Turns ON only outputs 1 and 2 of the MT108-103 card located in slot #5 of the MT100-100 Enclosure with unit ID3. 2) [ON3C5U3]: Turns ON only output 3 of the MT108-103 card located in slot #5 of the MT100-100 Enclosure with unit ID3. After the [ON12C5U3] and [ON3C5U3] commands have been executed, outputs 1, 2 and 3 will be ON. 3) [ONC5U3]: Turns ON all outputs of the card. This is the equivalent of sending the command [ON1234C5U3]. [ONmGkUi]: for a group of cards This command enables output "m" for each card in group "k" of unit "i". m = card output (m = # from 1-4) k = group number (k = # from 1-9) i = unit number (i = # from 0-9) 7 MULTI-TASKER Example: 1. [ON1G5U1]: Turns ON output 1 for each card in group 5 of unit 1. 2. [ONG5U1]: Turns ON all outputs for each card in group 5 of unit 1. [ON…P]: sets path This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. Command Format: [ONmCnUiP] m = number (m =1 to 4) n = card ID No. (n = a slot # from 1 to 19) i = unit ID P = path Example: If 2 cards are in slot 6 and 7 of unit 3: To enable outputs 1 and 2 of card 6 and outputs 3 and 4 of card 7 simultaneously, use the following commands: [ON12C6U3P] [ON34C7U3P] [SW] If "F" is included use the [ONmCnUiPF] command or the [ONmCnUiFP] command. [ON…..F]: feedback After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string. Example: [ON1C2U3F]: if path is not set [ON1C2U3PF]: if path is set 6. [OFF] This command disables one or more outputs of a single card or a group of cards. [OFFmCnUi]: for a single card This command disables output “m” without affecting any other outputs. m = output number (m = 1 to 4) n = card ID No. (n = slot # from 1 to 19) i = Unit ID number (i = 0 to 9) [OFFCnUi]: Turns OFF all outputs of the card Example: 1) If card 5 of unit 3 has output 1, 2 and 3 ON: a) [OFF1C5U3]: Turns OFF output 1 while outputs 2 and 3 remain ON. b) [OFF23C5]: Turns OFF outputs 2 and 3. 2) If card 5 of unit 3 has outputs 1, 2, 3 and 4 ON: a) [OFFC5U3]: Turns OFF all outputs, which is equivalent to [OFF1234C5U3]. [OFFmGkUi]: for a group of cards This command disables output "m" for each card in group "k" of unit "i". Command Format: [OFFmCnUiP] m = card output (m = # from 1-4) k = group number (k = # from 1-9) i = unit number (i = # from 0-9) Example: 1. [OFF1G5U1]: Turns OFF output 1 for each card in group 5 of unit 1. 2. [OFFG5U1]: Turns OFF all outputs for each card in group 5 of unit 1. [OFF…..P]: sets path This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. Command Format: [OFFmCnUiP] m = number (m =1 to 4) n = card ID No. (n = a slot # from 1 to 19) P = path 8 MULTI-TASKER Example: If 2 cards are in slots 6 and 7 of unit 3: To disabl...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias