DA1907LX General 400-0045-006 3 DISTRIBUTION AMPLIFIER MECHANICAL DA1907LX Material 0.1 in Al Finish Gray Top Panel Lexan Height 3.0 in (76 mm) Width 4.5 in (114 mm) Depth 1.0 in (25 mm) Weight 0.5 lb (0.2 kg) Shipping Weight (approx.) 1.0 lb (0.5 kg) T° Operating 10°C-35°C T° Maximum 45°C Humidity 90% non-condensing MTBF (calculations) 40,000 hrs ELECTRICAL DA1907LX Input Video Signal Analog Signal Level 1.5 Vp-p max Impedance 75 ohms Coupling DC Input Sync Signal Horizontal/Vertical or Composite TTL (+/-) Sync on Green -0.3 V Impedance 10 kohms Output Video Signals Gain 0 dB +/-0.5 dB Impedance 75 ohms Coupling DC Output Sync Signals Horizontal/Vertical or Composite TTL (+/-) Sync on Green -0.3 V Impedance 10 kohms Power Consumption External Adapter: 9 VDC 280 mA (2.5 W max.) Table 2. DA1907LX Mechanical Table 3. DA1907LX Electrical 400-0045-006 4 DISTRIBUTION AMPLIFIER 400-0045-006 5 PRODUCT DESCRIPTION 4 INPUT 15-PIN HD OUTPUT 2 15-PIN HD COMPUTER VIDEO COMPUTER VIDEO COMPUTER VIDEO OUTPUT 1 15-PIN HD DC POWER 2.5 mm COMPUTER VIDEO COMPUTER VIDEO OUTPUT 1 15-PIN HD OUTPUT 2 15-PIN HD DC POWER COMPUTER VIDEO 15-PIN HD 2.5 mm INPUT POWER/SIGNAL PRESENT LED DISTRIBUTION AMPLIFIER APPLICATION DIAGRAMS 5 DIAGRAM 1: TYPICAL SETUP DIAGRAM 2: INTERNAL VIEW 400-0045-006 6 DISTRIBUTION AMPLIFIER INSTALLING YOUR DA1907LX 6 OPERATION 7 Step 1. Connect the +9V AC adapter input to AC voltage and the output plug to the DA1907LX. Verify the LED in the top right corner of the unit’s front panel turns on and RED. Step 2. Connect the video output from the computer to the computer input connector on the DA1907LX using the cable provided. If a longer cable is required, make sure that the cable uses internal coaxial cables and that the cable is not excessively long. Step 3. Verify the LED on the face of the unit changes from RED to GREEN indicating an active signal is present. If the LED is not GREEN, the computer may not be sending video signals. NOTE: If using a laptop computer, the laptop may need to be set to output to the display to the external video port manually. Step 4. Connect the display devices (monitors and/or projectors) to Outputs 1 & 2 of the DA1907LX. Step 5. Verify the picture quality on both displays is good. If there is no signal, make sure that the display is compatible with the resolution of the computer graphics card. Step 6. The DA1907LX is now operational. The DA1907LX requires no adjustments for performance. Once set-up, the DA1907LX will work trouble-free without user intervention. TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied DA1907LX; however, we would like to offer suggestions for the following: 8.1 LED IS NOT RED The LED should be ON and RED when power is applied and ON and GREEN when the unit is receiving power and a SYNC signal. Cause 1: There is no AC power. Solution: Verify the supplied adapter is plugged into a working AC outlet and that the outlet has power. Cause 2: The adapter is not connected. Solution: Verify the DC power plug coming from the AC adapter is plugged all the way into the DA1907LX. Cause 3: The DA1907LX has a problem. Solution: If there is AC power to the adapter and the LED still does not turn on, the DA1907LX or the power adapter may require service. Call ALTINEX at (714) 990-2300. 8.2 LED IS NOT GREEN Cause 1: There is no power. Solution: Disconnect the video input from the DA1907LX and verify the LED is ON and RED indicating power is present. Reconnect the computer's video output. If the LED is still not GREEN see Cause 2. Cause 2: There is no Sync signal. Solution: Verify the computer output is operating correctly by connecting it directly to a local monitor. If the display is good, call ALTINEX at (714) 990-2300. 400-0045-006 7 DISTRIBUTION AMPLIFIER 8.3 NO REMOTE IMAGE Cause 1: The source has a problem. Solution: Check the image on a local monitor and verify the quality is good. If the local image is good, see Cause 2. Cause 2: Cable connections are incorrect. Solution: Make sure that all the cables are connected properly and that the continuity and wiring are good. If there is still no image, call ALTINEX at (714) 990-2300. 8.4 POOR IMAGE QUALITY Cause 1: The source has a problem. Solution: Check the image on the local monitor and verify the quality is good. If the local image is good, see Cause 2. Cause 2 Signal transmission is poor. Solution: Check the cables for continuity and make sure that connections are wired properly. If the image is still not correct, call ALTINEX at (714) 990-2300. ALTINEX POLICIES 9 9.1 LIMITED WARRANTY/RETURN POLICIES Please see the ALTINEX website at for details on warranty and return policies. 9.2 CONTACT INFORMATION ALTINEX, Inc. 592 Apollo Street Brea, CA 92821 USA TEL: 714 990-2300 TOLL FREE: 1-800-ALTINEX WEB: E-MAIL: solutions@altinex.com 400-0045-006 8 ...