|
Facilidade de uso
Each Data Cable Partition is one piece and has openings for routing data cables in and out of enclosures. Data Cable Partitions NetShelter SX Enclosures. Data Cable Partition AR8162ABLK (600-mm wide) AR8172BLK (750-mm wide) Pass-through Data Cable Partition AR8163ABLK (600-mm wide) AR8173BLK (750-mm wide) InfraStruXure Power Distribution Unit (PDU). Data Cable Partition, InfraStruXure PDU AR8182BLK (750-mm wide) Pass-through Data Cable Partition, InfraStruXure PDU AR8183BLK (750-mm wide) InfraStruXure InRow® RC. Data Cable Partition AR8184 (300-mm wide) Included with each partition rn 1 © 8-in ground strap (1) © M6 serrated lock washer (4) 0 M6 flanged hex nut (2) Installing Data Cable Partitions Use the procedure in this section to install all of the Data Cable Partitions. You can install Data Cable Partitions on a NetShelter Enclosure or a PDU. 1. Squeeze the two sides of the Pass-through Data Cable Partition to insert the fastening tabs into a set of square holes. 2. Determine the width that will be required for data cable routing, then install the Data Cable Partition at the front of the roof with a solid side in the same manner as step 1. © Note: Use a Data Cable Partition with a solid side at the front of the enclosure to ensure a finished appearance. 2 Data Cable Partitions—Installation Seismic environments Note: For installations in environments with seismic requirements, install cage nuts and screws (provided with enclosure) in the holes on the roof that are aligned with the holes on the partition. Data Cable Partitions—Installation 3 Bonding Data Cable Partitions and ladders To bond NetShelter Data Cable Partitions to one another: 1. Attach one end of an 8-in ground wire © to a ground stud on the partition and secure the ground wire with two M6 washers 0 and an M6 nut Q as shown. 2. Connect the free ends of the ground wires to the ground stud on the partition adjacent to the first partition, and secure the grounding wires with two M6 washers 0 and an M6 nut Q. Grounding ladders See “How to Ground the Ladder” in the Cable Ladder Installation with Troughs and Partitions Sheet, included with each Cable Ladder, for grounding instructions. 4 Data Cable Partitions—Installation 1иг MÜL ЛЯ ^viKU ЛИИРМ This manual is available in English on the APC Web site ( Dieses Handbuch ist in Deutsch auf der APC Webseite (verfügbar. Questo manuale è disponibile in italiano sul sito web di APC ( Ce manuel est disponible en français sur le site internet d’APC ( Este manual está disponible en español en la página web de APC ( 5>й APC h ( frhtf'b'sv'— Kftîto Este manual está disponível em portugués no site da APC ( Instrukcja obs3ugi w jêzyku polskim jest dostépna na stronie internetowej APC ( Данное руководство на русском языке доступно на сайте APC () ^APC^^^HiÈi ( Data Cable Partitions—...
Este manual também é adequado para os modelos :receptor e amplificador - AR8162ABLK (193.79 kb)