Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Kenmore, Modelo ELITE 153.33264

Fabricante : Kenmore
Arquivo Tamanho: 3.09 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Cap Maintain Manufacturer's Specified Minimum Clearance t **Maintain Support Strap\ Specified Clearance Maintain Clearance* f Vent Connector Chimney Flue Or Masonry Enclosure Venting Through Chimney With Type B Double Wall Vent Pipe, FIGURE 22. * Maintain vent pipe clearance requirements to local, state and/or the "National Fuel Gas Code", ANSI Z223.1(NFPA 54)-current edition. ** NFPA211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances states that these chimneys are intended to be installed in accordance with the installation instructions provided with each chimney support assembly. Minimum air space clearance to combustible materials should be maintained as marked on the chimney sections. Piping Installation Piping, fittings, and valves should be installed according to the installation drawing (Figure 23). If the indoor installation area is subject to freezing temperatures, the water piping must be protected by insulation. The water supply pressure should not exceed 80 psi. If this occurs, a pressure reducing valve with a bypass should be installed in the cold water inlet line. This should be placed on the supply to the entire house in order to maintain equal hot and cold water pressures. IMPORTANT: Heat cannot be applied to the water fittings on the heater as they may contain nonmetallic parts. If solder connections are used, solder the pipe to the adapter before attaching the adapter to the hot and cold water fittings. IMPORTANT: Always use a good grade of joint compound and be certain that all fittings are drawn up tight. 1. Install the water piping and fittings as shown in Figure 23. Connect the cold water supply (3/4" NPT) to the cold water inlet fitting. Connect the hot water piping (3/4" NPT) to the hot water outlet fitting. IMPORTANT: Some models may contain energy saving heat traps to prevent the circulation of hot water within the pipes. Do not remove the inserts within the heat traps. 2, The installation of unions in both the hot and cold water supply lines is recommended for ease of removing the water heater for service or replacement. 3, The manufacturer of this water heater recommends installing a mixing valve or an anti-scald device in the domestic hot water line as shown in Figure 24. These valves reduce the point-of-use temperature of the water by mixing cold and hot water and are readily available for use. 4. If installing the water heater in a closed water system, install an expansion tank in the cold water line as specified under Closed System/Thermal Expansion. 5. Install a shut-off valve in the cold water inlet line. It should be located close to the water heater and be easily accessible. Know the location of this valve and how to shut off the water to the heater. 6. A temperature and pressure relief valve must be installed in the opening marked "Temperature and Pressure (T & P) Relief Valve" on the water heater. A discharge line must be added to the opening of the T&P Relief Valve. Follow the instructions under Temperature and Pressure Relief Valve. 7. After piping has been properly connected to the water heater, remove the aerator at the nearest hot water faucet. Open the hot water faucet and allow the tank to completely fill with water. To purge the lines of any excess air, keep the hot water faucet open for 3 minutes after a constant flow of water is obtained. Close the faucet and check all connections for leaks. 21 In a closed system use a _r ,/thermal expansion tank Cold Water I]Pressure Reducing inlet Valve HValve with Bypass Hot Water,.._ Outlet =:_ [_ _Cold Water Supply/_ H_H to Fixture SupplyMain_Water Metal Drain-.., Pan 1-3/4" Depth Max. Typical water piping installation FIGURE 23. _,_ Mixed Water To Fixtures Unmixed Hot Water _]_,_ Cold Water Hot _ Inlet Outlet (Set To 120oF) Mixing Valve Follow The Mixing Valve Manufacturer's Instructions FIGURE 24. Please note the following: • The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, or polybutylene. This water heater must not be installed using iron piping or PVC water piping. • Use only pumps, valves, or fittings that are compatible with potable water. • It is recommend that only full flow ball or gate valves are used in water piping installations. The use of valves that may cause excessive restriction to water flow is not recommended. • Use only 95/5 tin-antimony or other equivalent solder. Any lead based solder must not be used. • Piping that has been treated with chromates, boiler seal, or other chemicals must not be used. • Chemicals that may contaminate the potable water supply must not be added to the piping system. Closed System/Thermal Expansion Pmpe_y Damage Hazard • All water heaters eventually leak • Do notinstallwithoutadequate drainage. As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water press...

Este manual também é adequado para os modelos :
Planes - ELITE 153.33262 (3.09 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias